• 제목/요약/키워드: Harmonics Effect

검색결과 240건 처리시간 0.292초

Walsh-Fourier 변환을 사용한 PWM 인버어터의 고조파 제거 방법 (A Harmonic Elimination Method of PWM Inverter Using Walsh-Fourier Transform)

  • 안두수;원충연;이해기;김태훈;김학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.296-300
    • /
    • 1989
  • The paper proposes a method to eliminate harmonics of PWM inverter fed induction motor system using Walsh series. In other words, this paper presents technique of the selective harmonics elimination(SHE) by W-FT series in three phase PWM inverter output waveform. A microprocessor(8086 CPU) - controlled three phase induction motor system in order to verify this algorithm is present. It is designed for a three output voltage in the 1$\sim$60 Hz inverter with the 5th and 7th harmonics, 5th, 7th, 11th, and 13th, harmonics eliminated, and with the fundamental wave amplitude proportional to the output frequency. In the PWM inverter, dead time circuit is inserted in the switching si gnats to prevent the de link shortage. This paper is deals with quantative prediction of dead-time effect and its compensation in PWM inverters. The performance of the compensation circuits is confirmed by the experiment.

  • PDF

수동형 필터의 리액터 및 커패시터 특성 해석 (Characteristics Analysis of Reactor and Capacitor for Passive Filter)

  • 김일중;김종겸
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.82-88
    • /
    • 2009
  • 전력용 커패시터는 유도성 부하의 낮은 역률을 보상하기 위해 설치하는 경우가 많지만, 전력변환장치에서 발생하는 고조파를 줄이기 위해 수동형 필터로서 리액터와 함께 사용되는 경우도 있다. 수동형 필터는 커패시터와 리액터를 직렬로 연결하여 사용한다. 필터는 비선형 부하에서 발생하는 고조파를 흡수하는 역할을 하기 때문에 전압 및 전류 스트레스를 받아 소손 또는 열화되어 정상적인 수명을 보장받지 못하는 경우가 많다. 본 논문에서는 PWM 인버터의 전원측에 설치된 수동형 필터가 고조파를 저감할 때 받는 영향을 해석하였다.

온라인 전기자동차 시스템의 고조파 및 고주파가 배전계통에 미치는 영향에 관한 연구 (Effect of Harmonics and High-Frequency on OLEV System in Distribution Power System)

  • 최성호;허재선;한운기;김재철
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.738-745
    • /
    • 2014
  • Recently, various measures have been discussed for overcoming depletion of fossil fuels and environmental pollution. One of the measures is electric vehicles. But electric vehicles has some limitations from high cost of battery and low efficiency, so operation distance of electric cars is limited. Also there are difficulties that charging lines should be connected by an electric car whenever it charges. Thus, many studies have been conducted to overcome the limitation using conventional batteries of electric vehicles. As a result, the OLEV(On-Line Electric Vehicle) was developed. But the OLEV system is some limitations. The OLEV system causes power quality problems when it charges. Power quality problem cannot be ignored because OLEV systems are closely connected by distribution grids. In this paper, the OLEV system is designed by using PSCAD/EMTDC, and the power quality is measured and evaluated. Power quality is divided by two cases; harmonics and high-frequency. Harmonics were evaluated according to IEEE Std. 519-1992. But the evaluation of High-frequency could not take it because there was no standard. For this reason, the data measured by OLEV system was compared with the EN50065 regulation.

A Study on the Harmonics Effect of SVC in Electric Arc Furnace Loads

  • Kim, Kyung-Chul;Jin, Seong-Eun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.54-60
    • /
    • 2006
  • Large steel industries have time-varying nonlinear loads such as electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. The main objective of the static var compensator is to maintain the rms voltage at the point of common coupling within the limit. In this research, harmonic mitigation studies were conducted with and without the SVC, and time-varying harmonics were evaluated according to the international harmonic standards (IEC 61000-3-6 and IEEE Std. 519) using a cumulative probabilistic approach.

새로운 고조파 저감형 고역율 단상정류 회로 (A New Harmonics Reducing Type High Factor Single-Phase Rectifier Circuit)

  • 김칠용;문상필;조만철;서기영;권순걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.468-472
    • /
    • 2007
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations

  • PDF

2-3 ? 변환방식에 의한 새로운 고조파 저감형 컨버어터 시스템 (A New Converter System of Reducing Harmonics by 2-3 Switching Taps on Interphase Reactor)

  • Lee, Seong-Ryong
    • 대한전자공학회논문지
    • /
    • 제24권4호
    • /
    • pp.658-666
    • /
    • 1987
  • In this paper, a new mehtod of reducing harmonics that involved in input AC line currents or in output DC voltage of the converter system is presented. which is due mainly to the quipment of 2-3 switching taps on interphase reactor. In case that the 3 tap method is applicable to conventional 12 pulse converter, it could not bring to an effect of reducing harmonics under firing angle 15\ulcorner To solve these problems, 24 pulse or 36 pulse converter is controlled by microprocessor. The former is performed in 2 tap method when \ulcorneris less than 15\ulcorner the latter in 3 tap method when it is more then 15\ulcorner Therefore the originality of this paper liea in microprocessor based equipment of the 2-3 switching taps on interphase reactor. I applied this method to the 12 pulse converter, and proved validity of that theoretically and experimentally.

  • PDF

태양광 발전시스템의 네가티브 컨덕턴스를 이용한 계통연계형 인버터 (Grid-Connected Inverter Using the Negative Conductance of Photovoltaic Power System)

  • 이창희;박기락;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2002
  • This paper proposes a grid-connected inverter using the negative conductance of PV power system, which has four IGBTs and simple controller. Most of modern electric loads generate the current harmonics and the line voltage distortion. The new solar-to-ac converter(STAC) provides by emulating a negative conductance load to the line voltage, so the current harmonics from STAC is canceled the effect of the harmonics from other loads. As a result, the line voltage distortion is decreased. The proposed system have low cost, small size, and light weight compared to conventional photovoltaic converter

  • PDF

자극분할형 동기전동기의 기본특성 (Basic Characteristics of Synchronous Motor with Divided Permanent Magnets per Pole)

  • 오누끼 다까시;전우진;와타나베 히데끼;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.133-135
    • /
    • 1997
  • In this paper, we propose a new type of rotor construction in the permanent magnet synchronous motor. By using plural permanent magnets for one-role of the rotor, it is possible not only to reduce space harmonics of air-gap fields but also to provide spacs for damper windings in the inter-pole space. The dimensions of the plural permanent magnets are derived by Fourier analysis. Based on the investigation by numerical analyses. we propose an optimal rotor construction in view of both the reduction of space harmonics and the damping effect.

  • PDF

PCR과 인버터의 결합에 의한 고조파 해석 (The Harmonic Analysis for Inverter related with PCR)

  • 강설묵;구본호;권우현;김수중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(I)
    • /
    • pp.779-781
    • /
    • 1987
  • In phase controlled rectifier(PCR), harmonica are changed according to the variation of a firing angle. These harmonics are supplied with the input of the inverter. And then, inverter output comes about the harmonics combined with the switching frequency of the inverter. Hence the efficiency of the induction motor ia decreased by the harmonic of the inverter output. In this paper, it analyzed about an effect of these harmonics ia analyzed by a computer simulation. The total harmonic distortion (THD) in the case of PCR containing the ripple was considerably larger than THO of the DC source. Therefore, it was proved that the firing angle variation of PCR had to be limited.

  • PDF

Rotor Loss Analysis of Permanent Magnet High-Speed Machine According to Magnetization Pattern

  • Cho, Han-Wook;Jang, Seok-Myeong;Lee, Sung-Ho;Yang, Hyun-Sup;Jeong, Yeon-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.103-107
    • /
    • 2004
  • Recently, greater attention has been paid to the high-speed generator for its many merits, such as ease of installation, high efficiency and high power density. However, due to their high fundamental frequency, careful consideration needs to be given to both electromagnetic and mechanical design issues. This paper deals with the comparison of two types of permanent magnet high-speed machines. Specifically, the effect of the permanent magnet magnetization pattern on the rotor losses is investigated. On the basis of analytical field analysis and the 2-D finite element method, this paper predicts the flux harmonics and rotor losses under the no-load condition. It is shown that the Halbach magnetization is superior to parallel magnetization in terms of producing rotor losses.