Torque Density Improvement of Five-Phase PMSM Drive for Electric Vehicles Applications

  • Zhao, Pinzhi;Yang, Guijie
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.401-407
    • /
    • 2011
  • In order to enhance torque density of five-phase permanent magnetic synchronous motor with third harmonic injection for electric vehicles (EVs) applications, optimum seeking method for injection ratio of third harmonic was proposed adopting theoretical derivation and finite element analysis method, under the constraint of same amplitude for current and air-gap flux. By five-dimension space vector decomposition, the mathematic model in two orthogonal space plane, $d_1-q_1$ and $d_3-q_3$, was deduced. And the corresponding dual-plane vector control method was accomplished to independently control fundamental and third harmonic currents in each vector plane. A five-phase PMSM prototype with quasi-trapezoidal flux pattern and its fivephase voltage source inverter were designed. Also, the dual-plane vector control was digitized in a single XC3S1200E FPGA. Simulation and experimental results prove that using the proposed optimum seeking method, the torque density of five-phase PMSM is enhanced by 20%, without any increase of power converter capacity, machine size and iron core saturation.

직접 방사형 스피커의 비선형 고조파 왜곡 보상 제어기의 설계 (Controller design for compensation of nonlinear harmonic distortion in direct-radiator loudspeakers)

  • 김윤선;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.399-402
    • /
    • 1996
  • The electrodynamic loudspeakers should have a wide dynamic range to reproduce various sound levels. When the input signal is small, the radiated sound from the loudspeaker is not so much distorted. However, for large input signal with low frequency component the radiated sound is significantly distorted due to the nonlinearities of the loudspeaker. The suspension, damping, and magnetic flux of loudspeaker are the main sources of the nonlinearity. Such electromechanical parameters related to harmonic distortion have been represented by a polynomial model for diaphragm displacement, while each of the polynomial coefficient is evaluated by using the principle of harmonic balance experimentally. Based on the polynomial model, we designed a compensator for nonlinear harmonic distortion of direct radiator loudspeaker. Than observer is used to estimate the displacement of the loudspeaker diaphragm, which is rather difficult to measure directly in the conventional setting. The usefulness of the designed compensator is demonstrated by numerical simulations. Simulation results show about 30db decrease at the second and third higher harmonic distortions. We carry out an experiment on speaker to verify designed controller and nonlinear observer.

  • PDF

액시얼 마그네틱 하모닉 기어의 특성 해석 (Characteristic Analysis of Axial Magnetic Harmonic Gear)

  • 원훈희;정광석
    • 융복합기술연구소 논문집
    • /
    • 제10권1호
    • /
    • pp.25-29
    • /
    • 2020
  • Magnetic gears of non-contact power type have great advantages in terms of maintenance and repair than mechanical gears, and are used in various ways. Harmonic gears can derive a higher gear ratio than conventional gears through power transmission through a unique rotation mechanism. Magnetic harmonic gears, in which the gear teeth of the harmonic gears are replaced with magnets, have the advantages of both gears, but are difficult to implement and practical, so many studies are being conducted. In this study, we check whether the results of various types of magnetic gears can be applied to harmonic gears. By applying the axial type magnetic gear to the harmonic gear, the characteristic analysis is conducted to see if the result comparable to the existing radial type magnetic harmonic gear is obtained.

Comparative Study of Flux Regulation Methods for Hybrid Permanent Magnet Axial Field Flux-switching Memory Machines

  • Yang, Gongde;Fu, Xinghe;Lin, Mingyao;Li, Nian;Li, Hao
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.158-167
    • /
    • 2019
  • This research comparatively studies three kinds of flux regulation methods, namely, stored capacitor discharge pulse (SCDP), constant current source pulse (CCSP), and quantitative flux regulation pulse (QFRP), which are used for hybrid permanent magnet (PM) axial field flux-switching memory machines (HPM-AFFSMMs). Through an analysis of the operation principle and the series hybrid PM flux regulation mechanism of the objective machine, the circuit topologies and flux regulation process of these flux regulation methods are addressed in detail. On the basis of a simulation, the flux regulation characteristics of the researched machine during the magnetization and demagnetization processes are comparatively evaluated. Then, machine performance, including back EMF, direct and quadrature axis inductances, and magnetization and demagnetization characteristics, is quantitatively investigated. Results show that the QFRP enables the HPM-AFFSMM to achieve a less harmonic component of back EMF by approximately 7.28% and 7.97% at the magnetization and demagnetization states, respectively, and a more complete magnetization process than the SCDP and CCSP.

Influence Analysis of Power Grid Harmonics on Synchronous Hydro Generators

  • Qiu, Hongbo;Fan, Xiaobin;Feng, Jianqin;Yang, Cunxiang
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1577-1584
    • /
    • 2018
  • The content of harmonic current increases with an increase in the number of power electronic devices in power grid. When a generator is directly connected to the power grid through a step-up transformer, the influence of the harmonic currents on the generator is inevitable. To study the influences of harmonics on generators, a 24-MW bulb tubular turbine generator is taken as an example in this paper. A 2-D transient electromagnetic field model is established. Through a comparative analysis of the data of experiments and simulations, the correctness of the model is verified. The values of the air gap magnetic density, torque and losses of the generator under various conditions are calculated using the finite element method. Taking the rated condition as a reference, the influence of the harmonic currents on the magnetic flux density is analyzed. It is confirmed that the time harmonic is a key factor affecting the generator performance. At the same time, the effects of harmonic currents on the torque ripple, average torque and eddy current loss of the generator are studied, and the mechanism of the variation of the eddy current loss is also discussed.

Improved HPC method for nonlinear wave tank

  • Zhu, Wenbo;Greco, Marilena;Shao, Yanlin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권6호
    • /
    • pp.598-612
    • /
    • 2017
  • The recently developed Harmonic Polynomial Cell (HPC) method has been proved to be a promising choice for solving potential-flow Boundary Value Problem (BVP). In this paper, a flux method is proposed to consistently deal with the Neumann boundary condition of the original HPC method and enhance the accuracy. Moreover, fixed mesh algorithm with free surface immersed is developed to improve the computational efficiency. Finally, a two dimensional (2D) multi-block strategy coupling boundary-fitted mesh and fixed mesh is proposed. It limits the computational costs and preserves the accuracy. A fully nonlinear 2D numerical wave tank is developed using the improved HPC method as a verification.

Design of Coaxial Magnetic Gear for Improvement of Torque Characteristics

  • Shin, H.M.;Chang, J.H.
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.393-398
    • /
    • 2014
  • This paper proposes new types of models that have coaxial magnetic gear (CMG) configurations to increase torque transmission capability. They have flux concentrating structures at the outer low speed rotor, and permanent magnets (PMs) are embedded in the space between stationary pole pieces. The torque performances of the proposed models are compared with those of a basic CMG model. The harmonic torque components due to air gap field harmonics are also analyzed to investigate the torque contribution of each harmonic by using finite element analysis (FEA) and the Maxwell stress tensor. The proposed CMG model is optimized to have high torque density with low torque ripples by response surface methodology (RSM). Compared to the basic CMG model, the proposed model has a huge increase in transmitted torque density, and is very advantageous in term of PM use.

Analysis Method Using Equivalent Circuit Considering Harmonic Components of the Pole Change Motor

  • Nam Hyuk;Jung Tae-Uk;Kim Young-Kyoun;Jung Seung-Kyu;Hong Jung-Pyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.162-167
    • /
    • 2005
  • This paper deals with the method of characteristic analysis of the capacitor-run single- phase induction motor having two poles (4-pole and 2-pole). This motor, which is referred to as a pole change motor in this paper, is capable of variable speed operation without inverters or drives. However, speed-torque curve can be distorted by the harmonic components contained in the magnetic flux density distribution. Therefore, the characteristics of this motor are analyzed using equivalent circuit considering harmonic components and the simulation results are compared with the experimental results.

공간고조파법을 이용한 영구자석 선형 동기전동기의 슬롯을 고려한 정특성 해석 (Analysis of Static Characteristics of PMLSM Using Space Harmonic Analysis Considering Slot Structure)

  • 임기채;홍정표;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권4호
    • /
    • pp.145-151
    • /
    • 1999
  • This paper presents the characteristic analysis method of PMLSM based on the Space Harmonic Analysis method considering the effect of stator slots. The magnetic field for unslotted primary can be easily calculated by the conventional space harmonic analysis method and the resultant magnetic field including slot effect is obtained using the concept of the virtual Equivalent Magnetizing Current(EMC) on primary core. And the influence of space harmonics in airgap flux density and static thrust due to slots is evaluated. In this paper, the results of the analytical method are compared with not only the experimental ones but ones of FEM to verify the validity of the proposed method.

  • PDF

전력용변압기보호를 위한 개선된 수치계전기법 (Advanced Numerical Relaying for Power Transformer Protection)

  • 박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.217-219
    • /
    • 2004
  • The second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic-restrained RDR needs modification. This paper describes an advanced numerical algorithm that utilizes terminal voltage, differential current harmonics, harmonic ratio, and flux-differential current slope. Based on the results of testing with WatATP99 simulation data, the proposed algorithm was proven to be faster and more reliable.

  • PDF