• 제목/요약/키워드: Harmonic currents

검색결과 343건 처리시간 0.022초

전기철도시스템에서 궤도회로 측면의 귀선전류 고조파 분석 (Analysis of Harmonic Frequency for Return Current on the Track Circuit in Electrical Railway System)

  • 백종현
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.698-704
    • /
    • 2012
  • Electric power used in electrical vehicles flows into the substation through the feedback circuit, track circuit. Due to these power conversion equipments in electrical railroads, return current contains harmonics, and it should not affect other communication lines. In this paper, based on the return currents, we measured harmonics and analyzed an influence in railway equipments due to the harmonics. For analysis, we utilize the measured values of return currents measured in track circuits, and predictive values of those compared to the earth methods between the existing electrified sections. Applying the regulations used for Gyeongbu HSL(High Speed Line), the results of measured harmonics have found to be acceptable.

대한해협조류의 3차원적 분포 (Vertical Distribution of Tidal Current in the Korea Strait)

  • 최병호;방인권;김경환
    • 한국해안해양공학회지
    • /
    • 제6권4호
    • /
    • pp.421-438
    • /
    • 1994
  • 대한해협 조류의 3차원적 분포를 3차원 조석모형에 의해 산정하였다. 모형의 결과는 8개분조의 조석도(등진폭도와 등위상도) 및 조류타원도로서 제시되었으며 또한 이 해역의 특정기간의 조석예보를 위한 분조의 조화상수의 data table로서 작성되었다. 모형의 조석산정결과는 연안관측치와 관측치를 근거한 Odamake(1989)의 조석도와 전선적인 일치를 보였으며 구주대학 응용역학연구소의 조석관측치를 이용한 검증도 수행하였다.

  • PDF

왜곡된 역기전력을 갖는 매입형 영구자석 동기전동기의 쇄교자속 고조파 관측기를 이용한 토크리플 저감 (Torque Ripple Reduction based on Flux Linkage Harmonics Observer for an Interior PM Synchronous Motor including Back EMF Harmonics)

  • 진용신;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제18권4호
    • /
    • pp.367-375
    • /
    • 2013
  • The mechanical vibration of a PM synchronous motor at low speeds due to the back emf harmonics may be serious problems in some application such as MDPS(Motor driven power steering), electric vehicles. In this paper, torque ripple reduction for an interior PM synchronous motor including back emf harmonics is proposed. The dq flux linkage harmonics of the permanent magnet are estimated on real time by using the dq currents of the real system and the model of the MRAS observer. Based on the estimated flux linkage harmonics, the dq harmonic currents for reducing the torque ripples are compensated on the dq reference currents. The estimation of the flux linkage harmonics by the MRAS observer and the torque ripple reduction of the proposed algorithm was verified by the simulation and experiment.

Diagnostic and Active Filtering of Harmonics Generated by Compact Fluorescent Lamps

  • Moulahoum, Samir;Houassine, Hamza;Kabache, Nadir
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.162-168
    • /
    • 2014
  • Use of nonlinear loads, such as power converters, fluorescent lamps and adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents. This paper presents the active filtering of the harmonic distortion generated by the compact fluorescent lamps (CFL). The Instantaneous active and reactive power theory (the p-q Theory) is used to design the control of parallel active filter. The control scheme has been verified using Matlab/Simulink with SimPower Systems through a set of simulation tests under different load conditions. Also, the tuning of the active power filter is performed to improve the quality of the electrical power supply.

단일전력단 고역률 Two-Switch Forward 컨버터 (Single-Stage High Power Factor Two-Switch Forward Converter)

  • 배진용;김용;조규만;이은영;이규훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.247-250
    • /
    • 2006
  • This paper presents the single-stage High Power Factor TSFC(Two-Switch Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

A PSpice Modeling of PFC Circuit Using Soft-Switched Boost Converter

  • Mok, H.S.;Choe, G.H.;Jeong, S.E.;Choi, J.Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.393-399
    • /
    • 1997
  • Single-phase and three-phase AC to DC power converters are becoming frequently used for high voltage/high power applications such as telecommunications. They often require input/output transformer isolation for safety, a unity input power factor for minimum reactive power, free input harmonic currents fed back to the AC Power distribution system and, finally, high efficiency and high power density for minimum weight and volume. The proposed boost converter for power factor correction (PFC) provides an unity input power factor, low harmonic distortion and high efficiency along with reduced volume and weight. Single-phase 220VAC input/380VDC 1KW output prototype is constructed and experimental results will be verified with those of PSpice simulation.

  • PDF

단일전력단 고역률 AC/DC Two-Switch Forward 컨버터 (Single-Stage High Power Factor AC/DC Two-Switch Forward Converter)

  • 배진용;김용;권순도;이규훈;계상범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.169-172
    • /
    • 2006
  • This paper presents the single-stage High Power Factor AC/DC Two-Switch Forward Converter (TSFC). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the simulation with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

전기철도 급전계통의 고조파 억제용 RC뱅크의 적정 위치에 관한 연구 (Optimal Location of RC bank limiting Harmonics in Electric Railway System)

  • 이한민;오광해;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1254-1256
    • /
    • 2001
  • This paper composes the Electric Railway System with the common grounding based on the 5-port network model. We compare the magnification ratio of harmonic currents according to locations of RC bank(i.e s/s. sp, and pp). It takes a lot of costs to equip the RC-bank at all location. And it is NOT effective that RC-bank is equipped at S/S. Finally, this paper proposes SP as the optimal site of RC-bank aspect reducing harmonic.

  • PDF

3상 모듈형 UPS용 PFC 제어기 설계 (A PFC Controller Design for 3-Phase Modular UPS)

  • 김상훈;박내춘
    • 산업기술연구
    • /
    • 제31권B호
    • /
    • pp.75-79
    • /
    • 2011
  • In this paper a new PFC Controller for 3-Phase Modular UPS(Uninterruptible Power Supplies) is proposed. The PFC circuit for 3-Phase Modular UPS is implemented using three 1-phase 3-level boost PFC circuits. To control DC output voltage, single voltage controller considering imbalance of two capacitor voltages and to regulate AC input current three independent current controllers are used in proposed PFC controller. By the proposed method, without additional hardware, THD(Total Harmonic Distortion) of input currents can be readily limited below 5% which is the harmonic current requirements by IEEE std. 519. Its validity is verified by simulations and experiments.

  • PDF

변압기 보호용 수정 전류차동 계전방식 (A Modified Current Differential Relay for Transformer Protection)

  • 강용철;김은수;원성호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.