• Title/Summary/Keyword: Harmonic current contents

Search Result 38, Processing Time 0.039 seconds

Single-Stage High Power Factor Two-Switch Forward Converter (단일전력단 고역률 Two-Switch Forward 컨버터)

  • Bae, Jin-Yong;Kim, Yong;Cho, Kyu-Man;Lee, Eun-Young;Lee, Kyu-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.247-250
    • /
    • 2006
  • This paper presents the single-stage High Power Factor TSFC(Two-Switch Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

Single-Stage High Power Factor AC/DC Two-Switch Forward Converter (단일전력단 고역률 AC/DC Two-Switch Forward 컨버터)

  • Bae, Jin-Yong;Kim, Yong;Kwon, Soon-Do;Lee, Kyu-Hoon;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.169-172
    • /
    • 2006
  • This paper presents the single-stage High Power Factor AC/DC Two-Switch Forward Converter (TSFC). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the simulation with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

PWM for Single Phase Inverter with 4 - Level Output (4 - 레벨 출력을 갖는 단상 인버어터의 PWM)

  • Jang, Hyun-Soo;Chin, Myung-Churl;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.527-530
    • /
    • 1989
  • In order to reduce harmonic contents in the inverter output, various PWM ( pulse with modulation ) techniques have been utilized. This paper suggests a single phase inverter with 4-level output and its PWM control scheme. The proposed 4-level output inverter shows better performence than the 3-level output one in respects of the current error and the switching frequency.

  • PDF

Decision of Modulation Index of Current-Source TPWM Inverter for Minimization of Speed Ripple and Position Error (속도맥동 및 위치오차를 최소로 하는 전류원 TPWM 인버터의 변조도 결정)

  • 구본호;권우현;김수중
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.11
    • /
    • pp.1819-1828
    • /
    • 1989
  • In this paper, we determined the modulation index for minimization of speed ripple and position error using maximum speed ripple (SRF) and maximum position error(PEF) in current source TPWM inverter. Through computer simulation, we compared with total current harmonic distortion, SRF and PEF for square wave modulation method and TPWM method. As a result, it turns out that square wave modulation method is superior to TPWM method of 3 pulses per half cycle in speed ripple and position error contents. And TPWM is better than square wave method when pulse number is more than 5. Also, in these pulse numbers, moduladtion index of minimum speed ripple and munimum position error is 0.91.

  • PDF

Study on a Novel Switching Pattern Current Control Scheme Applied to Three-Phase Voltage-Source Converters

  • Zhao, Hongyan;Li, Yan;Zheng, Trillion Q.
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1563-1576
    • /
    • 2017
  • This paper presents a novel switching pattern current control (SP-CC) scheme, which is applied in three-phase voltage-source converters (VSCs). This scheme can select the optimal output switching pattern (SP) by referring the basic principle of space vector modulation (SVM). Moreover, SP-CC is a method without a carrier wave. Thus, the implementation process is concise and easy. When compared with the conventional hysteresis current control (C-HCC) and the space vector-based hysteresis current control (SV-HCC), the SP-CC has the performances of faster dynamic response of C-HCC and less switching number (SN) of SV-HCC. In addition, it has less harmonic contents in the three-phase current, along with a lower switching loss and a higher efficiency. Moreover, the hysteresis bandwidth and Clarke conversion are not required in the SP-CC. The effectiveness of the presented SP-CC is verified by simulation and experimental test results. In addition, the advantages of the SP-CC, when compared with the C-HCC and SV-HCC, are verified as well.

Advanced Three-Phase PFC Power Converters with Three-Phase Diode Rectifier and Four-Switch Boost Chopper

  • Nishimura Kazunori;Hirachi Katsuya;Hiraki Eiji;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.356-365
    • /
    • 2006
  • This paper presents an improved three-phase PFC power rectifier with a three-phase diode rectifier cascaded four-switch boost converter. Its operating principle contains the operating principle of two conventional three-phase PFC power rectifiers: one switch boost converter type and a two switch boost converter type. The operating characteristics of the four switch boost converter type three-phase PFC power rectifier are evaluated from a practical point of view, being compared with one switch boost converter type and two switch boost converter topologies.

Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source (단상전원에 적합한 단일단 및 2단 역률개선회로)

  • Kim Chert-Jin;Yoo Byeong-Kyu;Kim Choong-Sik;Kim Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF

Improved Method for Calculating Magnetic Field of Surface-Mounted Permanent Magnet Machines Accounting for Slots and Eccentric Magnet Pole

  • Zhou, Yu;Li, Huaishu;Wang, Wei;Cao, Qing;Zhou, Shi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1025-1034
    • /
    • 2015
  • This paper presented an improved analytical method for calculating the open-circuit magnetic field in the surface-mounted permanent magnet machines accounting for slots and eccentric magnet pole. Magnetic field produced by radial and parallel permanent magnet is equivalent to that produced by surface current according to equivalent surface-current method of permanent magnet. The model is divided into two types of subdomains. The field solution of each subdomain is obtained by applying the interface and boundary conditions. The magnet field produced by equivalent surface current is superposed according to superposition principle of vector potential. The investigation shows harmonic contents of radial flux density can be reduced a lot by changing eccentric distance of eccentric magnet poles compared with conventional surface-mounted permanent-magnet machines with concentric magnet poles. The FE(finite element) results confirm the validity of the analytical results with the proposed model.

Line Current Characteristics of Multilevel H-Bridge Inverters: Part I - Connection of Input Transformer and Phase Shift Characteristics (다단 H-브릿지 인버터의 입력전류특성 (I) - 입력단 변압기 결선과 위상이동특성)

  • Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.229-236
    • /
    • 2008
  • Recently, multilevel H-bridge inverters have become popular in medium to high power ac drive applications. One of significant advantages of them is low harmonic contents in their input line currents thanks to the transformer with multiple phase-shifted secondary windings. This paper attempts to provide basic guidelines for the design of the phase shifting transformer windings and theoretical analysis of input line current harmonics of H-bridge inverters. The part I provides the derivation of basic relationships between input and output current of the transformer and the relationship between the phase shifting characteristics and design aspects of the transformer.

A Study on the UPS System based HF-Link AC to DC Converter (고주파 링크 AC/DC 콘버어터를 이용한 UPS 시스템에 관한 연구)

  • Mo, Chang-Ho;Lee, Su-Weon;Kim, Yeeug-Min;Park, Hyun-Chul;Yu, Chul-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.437-439
    • /
    • 1996
  • In this paper, an UPS system using high-frequency link AC to DC converter is Proposed. The AC to DC converter has sinusoidal input current and high power factor. In this UPS system, the waveform of the output voltage has smaller harmonic contents than those of a conventional UPS system. In this paper, an operating principle of the system is presented. This new control technique of the UPS system is capable of providing a wide range regulated output DC voltage compared with the conventional UPS system. Performance of the system carried out through theoretical and experimental means.

  • PDF