Decision of Modulation Index of Current-Source TPWM Inverter for Minimization of Speed Ripple and Position Error

속도맥동 및 위치오차를 최소로 하는 전류원 TPWM 인버터의 변조도 결정

  • Published : 1989.11.01

Abstract

In this paper, we determined the modulation index for minimization of speed ripple and position error using maximum speed ripple (SRF) and maximum position error(PEF) in current source TPWM inverter. Through computer simulation, we compared with total current harmonic distortion, SRF and PEF for square wave modulation method and TPWM method. As a result, it turns out that square wave modulation method is superior to TPWM method of 3 pulses per half cycle in speed ripple and position error contents. And TPWM is better than square wave method when pulse number is more than 5. Also, in these pulse numbers, moduladtion index of minimum speed ripple and munimum position error is 0.91.

Keywords