• 제목/요약/키워드: Harmonic constant

검색결과 215건 처리시간 0.027초

상대 가속도를 이용한 기초 가진을 받는 다자유도 기계 시스템의 동적 해석 (Dynamic Analysis for Mechanical Systems with Multi-Degree of Freedom under Base Excitation Using Relative Acceleration)

  • 이태원
    • 한국기계가공학회지
    • /
    • 제19권3호
    • /
    • pp.36-41
    • /
    • 2020
  • Mechanical systems installed in transport devices, such as vehicles, airplanes, and ships, are mostly subject to translational accelerations at the joints during operations. This base acceleration excitation has a large influence on the performance of the system, therefore, its response must be well analyzed. However, the existing methods for dynamic analysis of structures have some limitations in use. This study presents a new numerical method using relative acceleration to solve these limitations. If the governing equation of motion is linear and the mass matrix, the damping matrix, and the stiffness matrix are constant over time in the finite element analysis, the proposed method can be applied to the transient behavior analysis and the harmonic response analysis of the structure. Because it is not necessary to introduce a virtual mass and the rigid body motions are removed from the analysis, it is possible to use not only the direct integration method in the time domain but also the mode superposition method to obtain the dynamic responses. This paper demonstrates with three examples how the present method is suitable for the dynamic analysis of a structure with multi-degree of freedom.

Boussinesq 방정식을 이용한 규칙파의 연파해석 (Stem Wave Analysis of Regular Waves using a Boussinesq Equation)

  • 이종인;김영택;윤성범
    • 한국해안해양공학회지
    • /
    • 제19권5호
    • /
    • pp.446-456
    • /
    • 2007
  • 본 연구에서는 Lynett and Liu(2004a, b)에 의해 유도된 2층 Boussineaq방정식을 이용하여 일정수심상의 규칙파 조건에서 직립벽을 따른 연파를 해석하고, 수리모형실험결과 및 포물형근사식에 의한 해석결과와 비교하였다. 두 가지 수치모형에 의한 해석결과는 수리실험결과와 비교적 잘 일치하였으나, 입사각이 증가할수록 Boussinesq 모형이 포물형모형보다 우수한 결과를 주는 것으로 나타났다. 특히 파랑의 비선형성에 의한 고차 조화성분의 발생은 Boussinesq모형에서만 관찰되었다.

진동대실험에 의한 동조액체기둥감쇠기의 동적특성 (Dynamic Characteristics of Tuned Liquid Column Dampers Using Shaking Table Test)

  • 민경원;박은천
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.620-627
    • /
    • 2009
  • Shaking table test was carried out to obtain dynamic characteristics of TLCDs with uniform and non-uniform sections for both horizontal and vertical tubes. The input to the table is harmonic acceleration with constant magnitude. The output is horizontal dynamic force which is measured by load cell installed below the TLCD. Transfer functions are experimentally obtained using the ratio of input and output. Natural frequency, the most important design factor, is compared to that by theoretical equation for TLCDs with five different water levels. System identification process is performed for experimentally obtained transfer functions to find the dynamic characteristics of head loss coefficient and effective mass of TLCDs. It is found that their magnitudes are larger for a TLCD with non-uniform section than with uniform section and natural frequencies are close to theoretical ones.

Dynamics of the oscillating moving load acting on the hydroelastic system consisting of the elastic plate, compressible viscous fluid and rigid wall

  • Akbarov, Surkay D.;Ismailov, Meftun I.
    • Structural Engineering and Mechanics
    • /
    • 제59권3호
    • /
    • pp.403-430
    • /
    • 2016
  • This paper studies the dynamics of the lineal-located time-harmonic moving-with-constant-velocity load which acts on the hydro-elastic system consisting of the elastic plate, compressible viscous fluid - strip and rigid wall. The plane-strain state in the plate is considered and its motion is described by employing the exact equations of elastodynamics but the plane-parallel flow of the fluid is described by the linearized Navier-Stokes equations. It is assumed that the velocity and force vectors of the constituents are continuous on the contact plane between the plate and fluid, and impermeability conditions on the rigid wall are satisfied. Numerical results on the velocity and stress distributions on the interface plane are presented and discussed and the focus is on the influence of the effect caused by the interaction between oscillation and moving of the external load. During these discussions, the corresponding earlier results by the authors are used which were obtained in the cases where, on the system under consideration, only the oscillating or moving load acts. In particular, it is established that the magnitude of the aforementioned interaction depends significantly on the vibration phase of the system.

FACTS 기기의 고조파 저감을 위한 이중밴드 히스테리시스 전류 제어에 관한 연구 (A Study on Double Band Hysteresis Current Control based on 3-Level Inverter to reduce the harmonic component in output current of FACTS devices)

  • 최원경;최정혜;김범식;신은철;이상빈;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.180-182
    • /
    • 2005
  • The current control using a conventional hysteresis controller of a STATCOM based on two level VSI (Voltage Source Inverter) has high switching frequency and variable modulation frequency. This will increase the switching loss. In addition, the current error is not strictly limited So, in this paper to reduce the switching frequency and to maintain the constant modulation frequency, a novel double band hysteresis current controller based on 3-level VSI is proposed. A conventional hysteresis current control and a novel hysteresis current control was tested with digital simulation and verified the advantage of the novel hysteresis current controller.

  • PDF

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

전동차용 전원장치의 출력전압 제어 안정성 향상 (Stability Improvement of Output Voltage Control on the Power Supply for Railways)

  • 서광덕
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.134-141
    • /
    • 1999
  • 본 논문은 전동차량용 전원장치의 출력전압 제어 안정성을 향상시키기 위한 연구이다. 입력전압 변동 및 부하 변동 등 과도상태시 출력 정전압 제어를 수행할 경우, L-C 필터부에서 공진이 발생함으로써 출력전압이 흔들리고 시스템이 불안해진다. 본 논문에서, 출력전압제어의 안정성을 확보하기 위해 주필터부에 공진을 억제하는 댐핑회로를 새롭게 제안하고, 이에 적합한 제어방법을 소개한다. 제안한 댐핑회로는 R-L로서 소형이고 간단히 구성된다. 제어기에는 과도상태분의 궤환제어와 대역저지필터를 적용한다. 또한 전력회로는 3레벨 PWM방식을 적용하였다. 이로서 과도상태에서 출력전압의 흔들림없이 변동폭을 10[%]이하로 제어할 수 있었으며, 정상상태의 출력 전압 왜형율도 3[%]이하로 감소시켰다.

  • PDF

One Chip Microcomputer를 이용한 유도전동기 구동용 3동 전류형 인버어터시스템 (The Triple Current Source Inverter System for Induction Motor Drive Using a One Chip Microcomputer)

  • Chung, Yon-Tack;Jang, Seong-Chil;Hwang, Lak-Hoon;Lee, Hoon-Goo
    • 대한전기학회논문지
    • /
    • 제40권2호
    • /
    • pp.162-172
    • /
    • 1991
  • In proportion to the capacity enlargement of the induction motor system controlled by current source inverter, the capacitance of the commutating capacitor is enlarged and then the spike value of output voltage is increased at the moment of charge and discharge. Moreover, the output currnet includes a number of harmonic components. Such voltage spike and harmonics generate the torque ripple and lead to bad effects on the performance of the induction motor. In this study, all the harmonics excluding 17th and 19th harmonics were mostly elimunated by adopting 18-phase Triple High Frequency Current Source Inverter(HFCSI), and the spike component of output voltage was reduced by adding the Voltage Clamping Circuit(VCC). As a result, the torque ripple and the commutation loss were reduced and the performance of the system was improved. Experiments for speed control were carried out in the tripple current source inverter system for induction motor drive. Overall system was controlled by ONE CHIP MICROCOMPUTER(INTEL 8751). Control circuits were simplified and good experimental results in the constant V/F control were obtained due to the flexibility of the microcomputer.

  • PDF

Distortion Elimination for Buck PFC Converter with Power Factor Improvement

  • Xu, Jiangtao;Zhu, Meng;Yao, Suying
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.10-17
    • /
    • 2015
  • A quasi-constant on-time controlled buck front end in combined discontinuous conduction mode and boundary conduction mode is proposed to improve power factor (PF).When instantaneous AC input voltage is lower than the output bus voltage per period, the buck converter turns into buck-boost converter with the addition of a level comparator to compare input voltage and output voltage. The gate drive voltage is provided by an additional oscillator during distortion time to eliminate the cross-over distortion of the input current. This high PF comes from the avoidance of the input current distortion, thereby enabling energy to be delivered constantly. This paper presents a series analysis of controlling techniques and efficiency, PF, and total harmonic distortion. A comparison in terms of efficiency and PF between the proposed converter and a previous work is performed. The specifications of the converter include the following: input AC voltage is from 90V to 264V, output DC voltage is 80V, and output power is 94W.This converter can achieve PF of 98.74% and efficiency of 97.21% in 220V AC input voltage process.

3중구조 VCO를 이용한 Ka Band LNB 용 PLDRO 설계 및 제작 (Design and Implementation of a Phase Locked Dielectric Resonator Oscillator for Ka Band LNB with Triple VCOs)

  • 강동진;김동옥
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.441-446
    • /
    • 2008
  • In this papers, a PLDRO(Phase Locked Dielectric Resonator Oscillator) is designed and implemented at the oscillator in which fundamental frequency is 18.3 GHz. The proposed PLDRO so as to improve the PLDRO of the general structure is designed to the goal of the minimize of the size and the performance improvement. Three VCO(Voltage controlled Oscillator) and the power combiner improved the output power. A VCDRO(Voltage Controlled Dielectric Resonator Oscillator) is manufactured using a varactor diode to tune oscillating frequency electrically, and its phase is locked to reference frequency by SPD(Sampling Phase Detector). This product is fabricated on Teflon substrate with dielectric constant 2.2 and device is ATF -13786 of Ka-band using. This PLDRO generates an output power of 5.67 dBm at 18.3 GHz and has the characteristics of a phase noise of -80.10 dBc/Hz at 1 kHz offset frequency from carrier, the second harmonic suppression of -33 dBc. The proposed PLDRO can be used in Ka-band satellite applications

  • PDF