• 제목/요약/키워드: Harmonic Compensation Method

검색결과 135건 처리시간 0.021초

25kV 전기철도 고조파 보상을 위한 고전력 능동전력필터 시스템에 관한 연구 (The High Power Active Filter System for Harmonic Compensation of 25kv Electric Railway)

  • 김재철;노성찬;이유경
    • 한국철도학회논문집
    • /
    • 제9권6호
    • /
    • pp.761-765
    • /
    • 2006
  • At present, harmonic currents cause serious problems in power conversion system using the semiconductor switching device. Also some of the conversion system provokes harmonic currents against to the main power supply system and causes hindrances for the system. Main power impedance of the traditional LC passive filter method, influences on the filter characteristics and amplifies the harmonics when resonance phenomenon is occurred. And the traditional existing 2 level inverter systems show the limit in capacity of voltage and current in case of occurring sudden load change. So, to solve this problem active filter which uses cascaded H-bridge multi level inverter has been designed and ex-filter system circuits were totally investigated. With multi level active filtering system not only the size of filter but also the size of filter for transformer can be reduced by half and so as to the weight, while the capacity of inverter can be double sized and wave forms can be compensated exactly and precisely. Also by the benefit of the increase in rating capacity, the various currents owing to the load fluctuation can be dealt more steadily. In order to simulate the wave form of harmonics based on the measured data on the AC 25kV high speed Domestic Commercial railway, it was simulated with PSCAD/EMTDC and PSIM. Based on the results of this demonstration, the power supply system and inverter system would be more stable and also promoting its efficiency.

능력가변을 위한 단상유도전동기의 극수변환 방법에 관한 연구 (A Study of the Pole Change Method of the Single-Phase Induction Motor for Capability Variation)

  • 김규헌;정태욱
    • 한국산업융합학회 논문집
    • /
    • 제23권3호
    • /
    • pp.499-505
    • /
    • 2020
  • Capacitor-run single-phase induction motor is cheaper than motors that use permanent magnets and is widely used in home appliances and industries based on relatively high durability and productivity. It can also be operated by line. However speed cannot be controlled because the line frequency is free. In this paper we dealt pole change method one of the method controlling speed of capacitor-run single-phase induction motor. The conventional pole change method is difficult to improve the power and efficiency of the motor because the composition of the pole change device is complex and do not have enough area of the windings because of windings not used according to the driving conditions. In this paper, we proposed the pole change method that is used main windings and auxiliary windings at 4 poles operation and used auxiliary windings as compensation windings at 2 poles operation. The proposed method was verified through finite element analysis.

재귀형 최소 자승법을 이용한 자기 위치 센서의 실시간 보상 방법 (On-line Compensation Method for Magnetic Position Sensor using Recursive Least Square Method)

  • 김지원;문석환;이지영;장정환;김장목
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2246-2253
    • /
    • 2011
  • This paper presents the error correction method of magnetic position sensor using recursive least square method (RLSM) with forgetting factor. Magnetic position sensor is proposed for linear position detection of the linear motor which has tooth shape stator, consists of permanent magnet, iron core and linear hall sensor, and generates sine and cosine waveforms according to the movement of the mover of the linear motor. From the output of magnetic position sensor, the position of the linear motor can be detected using arc-tan function. But the variation of the air gap between magnetic position sensor and the stator and the error in manufacturing process can cause the variation in offset, phase and amplitude of the generated waveforms when the linear motor moves. These variations in sine and cosine waveforms are changed according to the current linear motor position, and it is very difficult to compensate the errors using constant value. In this paper, the generated sine and cosine waveforms from the magnetic position sensor are compensated on-line using the RLSM with forgetting factor. And the speed observer is introduced to reduce the effect of uncompensated harmonic component. The approaches are verified by some simulations and experiments.

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

계통전압 왜곡 및 불평형시 3상 계통연계인버터의 계통전류제어 기법 (Grid Current Control Scheme at Thee-Phase Grid-Connected Inverter Under Unbalanced and Distorted Grid Voltage Conditions)

  • ;전태원
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1560-1565
    • /
    • 2013
  • This paper proposes the control method for compensating for unbalanced grid current and reducing a total harmonic distortion (THD) of the grid current at the three-phase grid-connected inverter systems under unbalancd and distorted grid voltage conditions. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for a minimum point of THD. Both the gain and angle of a compensation voltage at the minimum point of THD of the grid current are derived. The negative-sequence components in the three-phase unbalanced grid voltage are cancelled in order to achieve the balanced grid current. The simulation and experimental results show the validity of the proposed control methods.

계통 연계형 인버터의 무효전력 공급을 고려한 Stack 설계 (The Stack Design Considering The Reactive Power Supply of Grid-Connected Inverter)

  • 고광수;오필경;김희중;김영민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.453-454
    • /
    • 2016
  • The ESS(Energy Storage System) connected with distributed generation is drawing attention due to improving the quality load leveling, peak shaving for enhancing reliability of the power grid. The grid-connected inverter makes frequency adjustment to the active power's charge discharge according to the load variation. In addition, the inverter is possible to act as a reactive power compensation device to eliminate harmonic operates as power factor change inhibiting, anti-transient voltage fluctuation, active filter. In this paper, we propose a design method of igbt stack considering the reactive power supply capacity to improve the quality and reliability of the inverter. Moreover, the grid-connected inverter considering the four-quadrant rated operation designed stack and verified the feasibility of the design through a thermal analysis.

  • PDF

공진모델을 이용한 3상 병렬형 능동전력필터의 데드비트제어 (Deadbeat Control of Three-Phase Shunt Active Power Filter Using Resonance Model)

  • 박지호;김동완
    • 전기학회논문지P
    • /
    • 제56권3호
    • /
    • pp.136-141
    • /
    • 2007
  • In this paper, a new simple control method for active power filter which can realized the complete compensation of the harmonic currents is proposed. In the proposed scheme, a compensating current reference generator employing resonance model implemented by a DSP(Digital Signal Processor) is introduced. Deadbeat control is employed to control the active power filter. The switching pulse width based SVM(Space Vector Modulation) is adopted so that the current of active power filter is been exactly equal to its reference at the next sampling instant. To compensate the computation delay of digital controller, the prediction of current is achieved by the current observer with deadbeat response.

무손실 공진기를 이용한 능동전력필터의 Deadbeat제어 (Deadbeat Control of Active Power Filter using Lossless Resonator)

  • 박지호;노태균;김춘삼;안인모;우정인
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.350-353
    • /
    • 1999
  • In this paper, a new simple control method for active power filter which can realized the complete compensation of the harmonic currents is proposed. In the proposed scheme, a compensating current reference generator employing lossless resonato implemented by a DSP(Digital Signal Processor) is introduced. Deadbeat control is employed to contro the active power filter. The switching pulse width based SVM(Space Vector Modulation) is adopted so that the current of active power filter is been exactly equal to its reference at the next sampling instant. To compensate the computation delay of digital controller, the prediction of current is achieved by the current observer with deadbeat response.

  • PDF

계통연계형 풍력발전시스템의 전력 품질 향상을 위한 새로운 고조파 보상기법 (A Novel Harmonic Compensation Method to Improve Power Quality in a Wind Power System)

  • 강성욱;김경화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.492-493
    • /
    • 2014
  • 비선형 부하 등에 의해 계통 전압의 왜곡이 존재하는 경우, 풍력발전 시스템과 같은 분산전원의 출력에는 5차, 7차, 11차 및 13차 고조파와 같은 저차 고조파 성분이 포함 되므로 풍력발전시스템의 전력품질이 저하 된다. 본 논문에서는 기존의 정지좌표계에서의 공진제어기를 이용한 보상기법 보다 연산량이 적고, 계통전압에 다수의 저차 고조파 왜곡이 존재하더라도 효과적으로 고조파를 보상할 수 있는 새로운 고조파 보상기법을 제안하며, 제안된 기법의 우수성을 시뮬레이션과 실험을 통해 증명하였다.

  • PDF

능동전력필터 기능을 갖는 다기능 준급속 충전기의 병렬운전 기법 (Parallel Operation Method of Multi Function Rapid-Charger with an Active Power Filter)

  • 배성훈;최성촌;신민호;송상훈;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.534-535
    • /
    • 2014
  • This paper proposes parallel operation of multi function rapid-charger with an active power filter. Rapid-charger can be installed in public institutions or mart parking lot. But conventional charger has disadvantage that it can not be used as the active power filter in charging mode with only one charger. So using 3-parallel operation, effective mode transfer between battery charging and APF function can obtain effect of harmonic compensation and improving the utilization of the charger.

  • PDF