• Title/Summary/Keyword: Harmful site

Search Result 122, Processing Time 0.026 seconds

McDoT: Multi-Channel Domain Tracking Technology for Illegal Domains Collection

  • Cho, Ho-Mook;Lee, JeongYoung;Jang, JaeHoon;Choi, Sang-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.127-134
    • /
    • 2020
  • Recently, Harmful sites, including pornographic videos, drugs, personal information and hacking tool distribution sites, have caused serious social problems. However, due to the nature of the Internet environment where anyone can use it freely, it is difficult to control the user effectively. And the site operator operates by changing the domain to bypass the blockage. Therefore, even once identified sites have low persistence. In this paper, we propose multi-channel domain tracking technology, a technique that can effectively track changes in the domain addresses of harmful sites, including the same or similar content, by tracking changes in these harmful sites. Proposed technology is a technology that can continuously track information in a domain using OSINT technology. We tested and verified that the proposed technology was effective for domain tracking with a 90.4% trace rate (sensing 66 changes out of 73 domains).

New Approach to the Care of Suction Drain Insertion Site by Using Occlusive Transparent Film Dressing (투명필름 밀폐 드레싱을 이용한 새로운 배액관 관리법)

  • Kwon, Soon Hong;Oh, Deuk Young;Choi, Youn Suk;Lee, Paik Kwon;Rhie, Jong Won;Han, Ki Taik;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.131-134
    • /
    • 2006
  • The closed suction drain is commonly inserted after various surgical procedures. It has an important role to prevent possible hematoma or seroma that can cause postoperative wound problems. But there is still no consensus on managing the insertion site of suction drain after operation. Suture-tie fixation of drain to skin and classical Y shape gauze dressing is a usually accepted method, but it has many limitations. We introduce a new approach to the care for the insertion site of suction drain by using occlusive transparent film dressing, $IV3000^{(R)}$(Smith & Nephew, London, UK). By using transparent film, insertion site of drain can be easily checked without removal of dressing. Because it can reduce the tension of suture-tie fixation, it helps to prevent skin injury. Furthermore, occlusive film dressing can block air leakage from insertion site of drain, and the water-proof character of film allows patients to take a shower without dressing change. This new method is more convenient, more efficient, and less harmful to skin than classic one.

A geochemical and Geophysical Study on the Environmental contamination in the Vicinity of Waste Dispodal Site (폐기물 매립지 주변지역에서의 환경오염에 관한 지구화학 및 지구물리학적 연구)

  • Kim, Kyoung-Woong;Shon, Ho-Woong
    • The Journal of Natural Sciences
    • /
    • v.8 no.1
    • /
    • pp.87-92
    • /
    • 1995
  • In the Vicinity of the Sindae-dong waste disposal site in Taejon, the average Cu, pb and Zn concentrations in soils are higher than those in other Korean soils but these are not high enough to cause any harmful effect to human and animal through the crop plants. Copper, Pb and Zn are not detected in the groundwater samples and F, Cl, $NO_2$, $NO_3$ and $SO_4$ concentrations in groundwater samples are lower than drinking water standards. However, the pH of groundwater sample in site D is 5.58 which is not suitable for the drinking water. With the electric resistivity method, the water-containg layers are found in contaminated soils and the resistivity values are considerably low because of the dispersion of plume by the leak of leachates. According to the results from the magnetic survey method, the anomalous values of the total geomagnetic fields and their gradients are found in the sampling site of low resistivity and high trace element concentrations.

  • PDF

Study on disinfection by-products formation according to kind of salt in on-site production (정수장 현장제조염소의 브로메이트와 클로레이트의 생성 특성연구)

  • Min, Byungdae;Chung, Hyenmi;Kim, Taewook;Park, Juhyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.575-581
    • /
    • 2015
  • Although disinfection in drinking water treatment plants provides a safer water supply by inactivating pathogenic microorganisms, harmful disinfection by-products may be formed. In this study, the disinfectant, chlorine, was produced on-site from the electrolysis of salt (NaCl), and the by-products of the disinfection process, bromate and chlorate, were analyzed. The provisional guideline levels for bromate and chlorate in drinking water are $10{\mu}g/L$ and $700{\mu}g/L$, in Korea, respectively. Bromide salt was detected at concentrations ranging from 6.0 ~ 622 mg/kg. Bromate and chlorate were detected at concentrations ranging from non-detect (ND) ~ 45.3mg/L and 40.5 ~ 1,202 mg/L, respectively. When comparing the bromide concentration in the salt to the bromate concentration in the chlorine produced by salt electrolysis, the correlation of bromide to bromate concentration was 0.870 (active chlorine concentration from on-site production: 0.6-0.8%, n=40). The correlation of bromate concentration in the chlorine produced to that in the treated water was 0.866.

Offsite Consequence Analysis and safety management system process integration plan of safety management system (장외영향평가 및 공정안전관리제도의 통합 안전환경관리방안에 관한 연구)

  • Kim, Dong-Jun;Lee, In-Bok;Moon, Jin-Young;Chun, Young-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.63-70
    • /
    • 2016
  • The main point of this study is to find out duplicates and differences among various regulations from different organizations. Also, it focuses on creating a reasonably unified regulation system to standardize safety & environment management. In this study, I analyzed the commonalities and the differences of two systems which are typical korean Process Safety Management System and off-site Consequence Analysis. It is confirmed that there are 25 species of overlapped material of those two systems and assessment like handling material information, facilities lists, hazardous substances and list of machine power. Process safety report focuses on onsite workers and facility protect. On the other hand, off-site Consequence Analysis focuses on design, arrangement and management of handling facility from off-site influence. I found difference two system of Enforcement purposes and way. Contradiction of Harmful information of Chemicals Control Act and occupation safety and health acts from same material. To be specific, There are no unit rule of occupation safety and health acts. so it permit inch, psi etc. But Chemicals Control Act provides that m, Mpa units. Therefore, Each regulatory duplication of items for chemicals management, standardization is writing so that you can coordinate overlapping items in the measures the need to be presented.

Atmospheric Concentrations of Semivolatile Bifunctional Carbonyl Compounds and the Contribution from Motor Vehicles

  • Ortiz, Ricardo;Shimada, Satoru;Sekiguchi, Kazuhiko;Wang, Qinyue;Sakamoto, Kazuhiko
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.152-160
    • /
    • 2013
  • Seven potentially harmful bifunctional carbonyls were measured in particulate and gaseous phases at a roadside site and a suburban site in an area about 30 km north-northwest from Tokyo metropolitan area in the Kanto region in Japan. For the first time, these compounds were measured in both phases with a time resolution of 2 h. We found that wind direction is an important parameter that affects the collection of these compounds near the source, and it can cover the effects of other important variables. Our results confirmed that motor vehicles and especially diesel fuelled vehicles are important sources of these compounds. Photochemical generation is also an important source of these compounds in the gaseous phase. Transportation from the urban area is also important, particularly in the aerosol phase.

Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses (공동주택의 배치유형에 따른 창호 시스템의 채광특성)

  • Kim, Gon;Roh, Ji-Woong
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2008
  • Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials.

Effect of Sulphur on the Nucleation Behavior of Graphite Crystals (흑연결정의 핵생성에 미치는 미량 유황의 영향)

  • Kim, Young-Jig
    • Journal of Korea Foundry Society
    • /
    • v.14 no.6
    • /
    • pp.520-529
    • /
    • 1994
  • This study describes the influence of the trace amount of sulphur on the nucleation behavior of graphite crystals in high purity Fe-C-Si alloys prepared by levitation melting method. Detailed microstructural analyses of high purity(HP) and sulphur added(HP+S) samples showed that the nucleation of graphite crystals was prevented by sulphur. With decreasing the sulphur content, the shape of graphite crystals tended to spherulitic, and below 2ppm S, that of graphite crystals was only nodular. The critical cooling rate for the nucleation of griphite crystals was calculated as $1.5{\times}10^3k/s$. It is obvious from this work that residual C-C clusters act as an effective nucleation site for graphite crystals and one of the important role of nodularizing elements is to act as scavenger which removes harmful impurities from the solution.

  • PDF

A Review of Standards for Allowable Limit of Blast Vibration According to the Safety Facilities and Improvement of Problems (보안물건의 종류에 따른 발파진동 허용기준 적용 사례 및 문제점 개선 연구)

  • Kim, Nam-Soo;Lee, Jong-Woo;Cho, Kyoung-Bin
    • Explosives and Blasting
    • /
    • v.31 no.2
    • /
    • pp.50-58
    • /
    • 2013
  • Since various types of safety facilities have been located around blasting construction site, each of the institutions with regard to blast works has prepared limit criterion of blast vibration, respectively. But these criterions applied for limiting vibration are causing harmful effect including construction cost increasement and construction time extension due to exceedable high level application. In this study, more reasonable limit of blast vibration was suggested after reviewing criterions based on existing design and construction cases and analyzing of problems of applied criterions.

Molecular Aspects of Organic Ion Transporters in the Kidney

  • Cha, Seok-Ho;Endou, Hitoshi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.107-122
    • /
    • 2001
  • A function of the kidney is elimination of a variety of xenobiotics ingested and wasted endogenous compounds from the body. Organic anion and cation transport systems play important roles to protect the body from harmful substances. The renal proximal tubule is the primary site of carrier-mediated transport from blood into urine. During the last decade, molecular cloning has identified several families of multispecific organic anion and cation transporters, such as organic anion transporter (OAT), organic cation transporter (OCT), and organic anion-transporting polypeptide (oatp). Additional findings also suggested ATP-dependent organic ion transporters such as MDR1/P-glycoprotein and the multidrug resistance-associated protein (MRP) as efflux pump. The substrate specificity of these transporters is multispecific. These transporters also play an important role as drug transporters. Studies on their functional properties and localization provide information in renal handling of drugs. This review summarizes the latest knowledge on molecular properties and pharmacological significance of renal organic ion transporters.

  • PDF