• 제목/요약/키워드: Harmful air

검색결과 418건 처리시간 0.033초

인천광역시 지하철 역사 내 지하수 및 수돗물의 라돈 위해성 검토 (Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station)

  • 이유상;이상복;강민석;정동하;김진홍;오윤식;최세린;박정수;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.671-677
    • /
    • 2021
  • Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

미세먼지 PM10에 노출된 RAW264.7 세포에 대한 해당화 추출물의 항염증 활성 (Anti-inflammatory effects of Rosa rugosa extracts in RAW264.7 cells exposed to particulate matter (PM10))

  • 안민아;현태경
    • Journal of Plant Biotechnology
    • /
    • 제49권2호
    • /
    • pp.145-149
    • /
    • 2022
  • 직경이 10 ㎛ 미만의 미세먼지 입자(particulate matter 10, PM10)는 한국을 비롯한 동아시아 지역에서 해로운 대기오염의 주요한 원인 중 하나로 최근 주목받고 있으며, 호흡기와 피부에 유해한 영향을 미치는 주범이 되고 있다. FD는 대식세포에서 활성산소 종(ROS)의 생성과 염증반응을 과도하게 촉진시켜 세포 손상과 더불어 세포 사멸을 유도한다. 장미속의 낙엽관목인 해당화(Rosa rugosa)는 다양한 질병을 치료하는 목적으로 예부터 동아시아 지역에서 민간요법 치료제로써 사용되었다. 본 연구에서는 PM10으로 유도된 RAW 264.7 대식세포에서의 염증반응을 억제하는 해당화 각 기관별 추출물의 항염증 효과를 탐색하고자 한다. 미세먼지 입자가 처리되지 않은 RAW 264.7 대식세포와 비교했을 때, PM10을 100 ㎍/ml의 농도로 처리했을 경우 lipopolysaccharide 처리와 유사하게 nitric oxide (NO) 생성을 눈에 띄게 증가시켰다. 또한 100 ㎍/ml의 해당화 줄기 추출물은 미세먼지 입자 단독 처리군에 비해 NO 생성을 45% 이상 감소시켰고, PM10에 의해 유도된 interleukin(IL)-1β, IL-6, inducible nitric oxide synthase, and cyclooxygenase-2의 발현을 유의하게 감소시켰다. 이러한 결과는 해당화 줄기 추출물의 항염증 효과가 PM10으로 자극된 RAW 264.7 세포에서 염증 유발 매개체의 억제에 의해 매개됨을 나타내며, 해당화 줄기가 유해한 공기 중 미세먼지 입자에 의해 유발되는 염증반응에 대한 보호 효과가 있는 천연 자원으로서 가치가 있음을 시사한다.

인간 각막상피세포에서 미세먼지로 인한 세포 손상을 완화할 수 있는 유익한 한약재의 탐색 (Exploration of Beneficial Herbal Medicines to Attenuate Particulate Matter-induced Cellular Injury in Human Corneal Epithelial Cells)

  • 김다혜;김민영;황보현;지선영;박세광;박성호;김미영;최영현
    • 생명과학회지
    • /
    • 제32권8호
    • /
    • pp.647-658
    • /
    • 2022
  • 미세먼지는 유해한 다양한 작은 입자를 가진 대기오염 물질로서 산화적 및 염증성 반응을 촉진하여 다양한 질환의 발병과 진행에 관여하는 것으로 알려졌다. 본 연구에서는 외부 오염물질에 직접적으로 노출되는 1차 노출 기관인 안구를 미세먼지로부터 보호할 수 있는 약재를 선정하기 위해, 인간 각막상피세포에서 후보 약물들의 방어 효능을 평가했습니다. 그 결과, 12종의 후보 약재 중 PM2.5에 의한 세포 독성 억제효능을 보인 후보 약재 5가지(천문동, 석창포, 황련, 감국 및 금잔화)를 선별하였다. 이들 후보 물질들의 항산화 활성을 평가하기 위하여 ROS 소거능을 조사한 결과, 석창포, 천문동 및 황련 추출물이 유의한 효과를 나타내었으며, 이는 미토콘드리아 활성 보존 효능과 다소 연관성이 있었다. 또한, 이들은 PM2.5에 의한 DNA 손상을 차단할 수 있었음을 8-OHdG 생성 및 γ-H2AX 발현 분석을 통하여 확인하였다. 본 연구의 결과는 PM2.5에 대한 각막상피세포의 보호 신규 천연물의 탐색을 위한 자료로 활용될 것이다.

Acetohydroxamic acid 이용한 Urea로부터 암모니아 발생 저감 연구 (Reduction of ammonia conversion from urea by adding acetohydroxamic acid)

  • 윤광수;오하은;정민웅;황옥화;윤여명
    • 유기물자원화
    • /
    • 제29권4호
    • /
    • pp.5-13
    • /
    • 2021
  • 가축분뇨의 요소에서 유래하는 암모니아는 미세먼지(PM2.5) 생성의 주요 전구체로 작용하여 대기질을 저하시키고 공중 보건에 유해한 영향을 미치는 것으로 알려져 있다. 본 연구의 목적은 Acetohydroxamic acid(AHA)의 주입에 따른 요소로부터 암모니아 전환의 억제에 대한 효과를 평가하는 것이었다. 실험은 다양한 요소 농도(500-4,000 mg Urea-N/L), AHA 농도(0-4,000 mg AHA/L), pH(pH 6-10) 및 온도(10-35℃)범위에서 수행되었다. 그 결과 AHA 농도가 높을수록 Urease 억제 효율이 증가함을 보여주었다. 그러나 특정 Urease 억제 활성은 pH가 높을수록 감소하여 pH 6에서 867.1±6.7 Unit/g AHA, pH 10에서 1,167.9±17.4 Unit/g AHA를 나타냈다. AHA와 대조군 모두에서 높은 온도에서 요소분해효소 억제 효율이 감소됨을 확인하였다. 본 연구결과를 통해 AHA가 가축분뇨 관리에서 암모니아 배출을 줄이기 위한 요소분해효소 억제제로 사용될 수 있음을 확인하였다.

랏트의 기관내 Fe 노출후 Fe 이동에 대한 연구 (The Mechanism of Iron Transport after Intratracheal Instillation of Iron in Rats)

  • 권민;최병선;박언섭;정남현;박성조;임영;박정덕
    • Journal of Preventive Medicine and Public Health
    • /
    • 제37권4호
    • /
    • pp.329-336
    • /
    • 2004
  • Objectives : Iron (Fe) is an essential element in biological processes; however excessive Fe is harmful to human health. Some air pollutants contain a high level of Fe, and the human lung could therefore be over-exposed to Fe through inhaled air pollutants. This study was performed to investigate the role of metal transporters (divalent metal transporter 1, DMT1, and metal transporter protein 1, MTP1) in the lung under the environments of Fe deficiency in the body and Fe over-exposure in the lung. Methods : Rats were fed Fe deficient (FeD, 2-6 mg Fe/kg) or Fe supplemented (FeS, 120 mg Fe/kg) diet for 4 weeks, followed by a single intratracheal instillation of ferrous sulfate at low (10 mg/kg) or high (20 mg/kg) dose. Fe concentration was analyzed in the serum, lung and liver, and histopathological findings were observed in the lung at 24 hours after Fe administration. The level of DMT1 and MTP1 expression in the lung was analyzed by RT-PCR. Also, the effect of Fe deficiency in the body was evaluated on the level of Fe concentration and metal transporters compared to FeS-diet fed rats at the end of 4-week FeD or FeS diet. Results : The 4-week FeD diet in rats induced an Fe deficiency anemia with decreased serum total Fe, increased unsaturated Fe binding capacity and hypochromic microcytic red blood cells. The concentration of Fe in the lung and liver was lower in the FeD-diet fed rats than in the FeS-diet fed rats. The level of metal transporters mRNA expression was higher in the FeD-diet fed rats than in the FeS-diet. The concentration of Fe in the lung was increased in a dose-dependent pattern after intratracheal instillation of Fe into the rats, while the level of Fe in the serum and liver was not increased in the low-dose Fe administered rats. Therefore, DMT1 and MTP1 mRNA was highly expressed in both FeD-diet and FeS-diet fed rats, after intratracheal instillation of Fe. Conclusions : DMT1 and MTP1 mRNA were more highly expressed in FeD-diet fed rats than in FeS-diet fed rats. The over-exposure of Fe intratracheally induced high expression of metal transporters and increased Fe deposition in the lung in both FeD-diet and FeS-diet fed rats, but did not increase the Fe level of the serum and liver in low-dose Fe administered rats. These results suggest that the role of metal transporters in the lung might be different in a part from the duodenum under the environment of over-exposure to Fe.

지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구 (A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform)

  • 유지오;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제24권4호
    • /
    • pp.327-339
    • /
    • 2022
  • 본 연구에서는 지하철 승강장에서 열차화재가 발생하는 경우, 승강장 제연풍량 및 제연모드(급기 또는 배기)에 따른 정량적 위험도 평가를 통해 안전확보에 효과적인 제연풍량 및 모드를 제시함을 목적으로 한다. 이를 위해 중앙계단을 갖는 상대식 승강장을 모델로 하여 화재발생 시나리오를 작성하였으며, 시나리오별 화재해석을 수행하여 연기전파특성과 ASET을 비교·분석하고 대피해석을 수행하여 사망자수를 예측하였다. 또한, 시나리오별로 화재사고 발생률(F)/사망자수(N)선도(F/N선도)를 작성하여 제연풍량 및 제연모드에 따른 위험도를 비교·평가하였다. 소방시설 등의 성능위주 설계 방법 및 기준에서 정하는 유해요소(일산화탄소, 온도, 가시거리)에 대한 ASET 분석에서는 가시거리의 영향이 가장 크게 나타나고 있으며, 화재열차의 승강장 진입지연을 고려하지 않은 경우에 풍량을 4 × 833 m3/min할 때 ASET은 약 800초 정도로 분석되었다. 예상사망자수는 화재차량위치에 따라 큰 차이가 있으며, 계단부에 인접한 차량에서 화재가 발생하는 경우에 선두부 차량대비 3배 까지 증가하는 것으로 나타나고 있다. 또한 제연풍량이 증가하면 사망자수가 감소하며 배기 보다는 급기방식이 감소율이 증가한다. 급기풍량이 4 × 833 m3/min일 때 예상 사망자수는 제연을 수행하지 않는 경우 대비 13%수준으로 감소하는 것으로 나타났다. 위험도 평가결과, 제연을 수행하는 경우에는 현행 사회적 위험도 평가기준을 만족하는 것으로 나타나고 있으며, 예상사망자수는 제연을 수행하지 않는 경우, 10,000년에 29.9명에서 제연을 수행하는 경우에는 풍량이 4 × 833 m3/min일 때 4.36명으로 감소하는 것으로 분석되었다.

통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 2012
  • 통풍과 차양이 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는지를 객관적으로 검증하기 위하여 통풍과 차양을 달리한 실험구를 조성하고 흑구온도와 기온 및 풍속을 측정하여 평균복사온도를 환산하여 비교 분석하였다. 미기후 측정을 위하여 개방된 잔디밭에 철제 각관을 이용하여 가로${\times}$세로${\times}$높이가 각각 $3m{\times}3m{\times}1.5m$인 프레임을 구성하고, 투명 폴리에틸렌 필름과 농업용 차광막을 이용하여 통풍과 차양의 조건을 달리한 네 가지의 실험구를 조성하였다. 각 실험구 내 중심부 지면으로부터 1.2m 높이에서 베인형 풍속계와 흑구, 측온저항체(PT-100)를 이용하여 2011년 5월 1일부터 동년 9월 30일까지 풍속과 기온, 흑구온도를 매 분 단위로 계측하였다. 기상조건과 계측자료의 유효성 등을 고려하여 총 44일 동안의 13,262건의 자료를 바탕으로 실험구별 일중 시계열적 변화를 분석하였으며, 낮 시간에 해당되는 오전 7시부터 오후 8시까지의 7,172건의 자료를 바탕으로 실험구에 따른 통계적 차이를 해석하였다. 아울러 햇볕이 가장 강렬한 시간대인 오전 11시부터 오후 4시까지의 자료를 바탕으로 평균복사온도와 풍속 및 일사량과의 관계를 분석하였다. 평균복사온도를 기준으로 해석했을 때, 통풍이 차단된 노지에서의 측정기간 중 최고값이 $58.84^{\circ}C$까지 상승한 반면, 차양이 적용되고 통풍이 원할한 실험구의 최고값은 $42.94^{\circ}C$였다. 시험결과를 종합하면, 하절기 옥외공간에서 낮 동안의 평균복사온도에 있어서 차양에 의해서는 최대 $13^{\circ}C$, 평균 $9^{\circ}C$의 냉각효과가 발생한 반면, 방풍에 의해서는 반대로 평균 약 $3^{\circ}C$의 가열효과가 있는 것으로 정리되어, 통풍이 되지 않는 태양직사광 지역은 바람이 원활하게 통하는 그림자 지역 보다 최대 $16^{\circ}C$까지 높은 것으로 나타났다. 결론적으로 본 연구를 통해서 하절기 옥외공간의 열쾌적성을 개선하는데 차양이 가장 중요하며, 그 다음이 통풍이라는 사실을 파악할 수 있었다. 따라서 옥외공간에 더 많은 녹음수와 숲을 조성하여 그림자 지역을 증가시킴으로써 인간의 하절기 옥외활동에 많은 제약을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 미기후를 효과적으로 조성할 수 있으며, 나아가 정교하게 조성된 바람길이나 통풍 시스템을 적용한다면 도시 전체의 열환경도 효과적으로 개선할 수 있을 것이다.

기체상 유해화학물질 제거를 위한 이동형 와류식 세정장치 개발 및 가스 제거효율 분석 (Development of Mobile Vortex Wet Scrubber and Evaluation of Gas Removal Efficiency)

  • 곽지현;황승율;이연희;김재영;송기봉;김균;강재은;이상재;전준호;이진환
    • 한국환경농학회지
    • /
    • 제34권2호
    • /
    • pp.134-138
    • /
    • 2015
  • 본 연구에서는 기존 스크러버의 분사노즐과 충진층의 폐쇄 위험성 및 장치의 복잡함으로 인한 단점을 극복하고 화학사고 발생 시 현장에서 유해물질의 신속한 처리가 가능하도록 이동형 와류식 세정장치를 제작하였다. 제작된 장치의 성능을 확인하기 위하여 후드 입구에서 유입풍량 조절에 따른 송풍기 배출구에서의 풍속변화를 확인하였으며, 분무연기 및 25% 암모니아 용액을 이용하여 성능평가를 수행하였다. 제작된 장치의 후드 댐퍼 개방 각도를 변화시킴에 따라 유입풍속(유입유량)이 변하는 것을 확인하였으며, 이는 물질의 용해도 특성 및 농도에 따라 유입풍속을 증감시켜 세정기 내에서의 체류시간을 조절하는데 유용할 것으로 판단된다. 제작된 장치의 유해가스 제거성능을 확인하기 위하여 분무연기와 25% 암모니아 용액을 이용하여 실험을 수행하였다. 세정기 후드의 댐퍼를 완전 개방시킨 상태에서 분무연기를 노출시킨 결과, 높은 유입 유량으로 인해 연기 일부는 와류 내에서 체류하지 못하고 송풍기로 배출되었다. 그러므로 암모니아 용액을 이용한 실험에서는 댐퍼 개방 각도를 60도로 설정하여 후드에 노출시켰다. 암모니아 용액을 30분간 세정기에 흡입시킨 후 물의 pH를 측정한 결과 12 이상으로 나타나 염기성의 암모니아 가스가 물에 충분히 흡수된 것을 관찰하였다. 후드 입구 및 송풍기 배출구에서 암모니아 농도 비교시, 체류시간 5분일 때 제거효율 83%로 최대로 나타났으며(pH 10) 이후로 급격히 감소하는 경향을 나타내었다. 이는 유해가스의 물에 대한 용해도외에도 체류시간이 세정액으로의 흡수 및 제거효율에 미치는 중요한 인자임을 나타낸다.

큰느타리버섯 재배사의 실태분석 - 서부경남지역을 중심으로 - (Analysis of Actual State of Facilities for Pleurotus eryngii Cultivation - Based on Western Gyeongnam Area -)

  • 윤용철;서원명;유찬
    • 생물환경조절학회지
    • /
    • 제13권4호
    • /
    • pp.217-225
    • /
    • 2004
  • 본 조사는 최근 급격히 증가하고 있는 새송이버섯 재배농가의 안정적 영농을 위해 재배사 설계, 시공 및 환경조절과 관련한 기초 자료를 마련하기 위해 서부 경남지역을 대상으로 새송이버섯 재배사의 재배사 규모, 환경조절시스템 등의 실태조사 및 검토를 하였다. 재배사의 형태는 반영구재배사와 영구재배사로 대별 할수 있었고, 반영구재배사는 대부분 단동이었고, 영구재배사의 경우는 단동에 비해 상대적으로 연동이 많았다. 그리고 재배사의 규모는 형태에 관계없이 다양하였지만, 길이, 폭 및 동고는 각각 20m, $6.6\~7.0m$$4.6\~5.0m$정도의 농가가 가장 많았으며, 동당 바닥면적은 $132\~140m^2$(40-42평)정도의 범위로서 대부분 콘크리트로 처리하여 각종 균에 의한 버섯의 오염을 방지 할 수 있도록 되어 있었다. 반영구 및 영구재배사의 지붕경사각은 각각 $41.5^{\circ}$$18.6\~28.6^{\circ}$로 나타나 반영구재배사의 지붕경사도가 더 큰 것으로 나타났다. 그리고 재배상의 폭 및 단수는 재배사의 형태에 관계없이 각각 $1.2\~1.6m$정도와 4단이 주류를 이루고 있었다. 버섯을 연중재배 하는 재배사에는 모두 냉${\cdot}$난방시설, 가습장치 및 환기팬이 설치되어 있었다. 난방방식의 경우, 온수보일러, 전기히터, 증기보일러 순으로 나타났다. 냉방장치의 경우는 모두 산업용 에어컨을 설치하여 운용하고 있었다. 그리고 가습은 초음파가습기와 원심분리가습기를 사용하고 있었으며, 보조 장치로 분무노즐을 사용하는 농가도 일부 있었다. 또한 온${\cdot}$습도 조절 및 탄산가스 조절을 위한 장치의 제어는 동별 제어시스템을 많이 채택하고 있었다. 그리고 온도센서 이외는 모두 타이머를 이용하고 있음을 알 수 있었다. 배지병의 크기는 850 cc 및 1,100 cc를 사용하는 농가가 주류를 이루고 있었고, 이 밖에도 800cc와 950 cc, 1,200 cc병을 사용하는 농가도 있었다. 출하형태는 대부분 유통회사와 공판장을 동시에 이용하고 있었다.

방사선 치료 시 치료실 내에서 발생하는 오존에 관한 고찰 (Consideration about Ozone Generation in the Treatment Room While Treating a Patient)

  • 곽용국;윤일규;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제21권2호
    • /
    • pp.75-82
    • /
    • 2009
  • 목 적: 방사선 치료 시 치료실 내에서 발생하는 오존량을 측정하여 오존 발생으로 인한 오염 정도를 알아보고자 한다. 대상 및 방법: 선형가속기(Clinac 21EX, Varian, USA)와 오존 측정기(series-200, aeroQual, New Zealand)를 이용하여 water phantom (Wellhofer, IBA, Germany)에 방사선을 조사하여 MU, 선량율, 선원-표면간 거리(SSD), 조사야, 에너지, 경과 시간에 따라 발생되는 오존량을 측정 분석하였으며, 실제 환자치료 시 치료실 내에 오존 측정기를 위치하여 일일 오존 변화량을 측정하였다. 결 과: 방사선 발생 중 생성되는 오존의 오염도는 에너지에 따른 영향을 크게 받지 않지만 대체로 광자선보다 전자선 조사 시(0.016~0.028 ppm/hr) 많이 발생하였다. 또한, Dose-Rate가 높을수록(0.016~0.025 ppm/hr), SSD가 멀어지고(0.018~0.030 ppm/hr), 조사야가 넓어지고(0.016~0.025 ppm/hr), MU가 많을수록(0.018~0.046 ppm/hr) 오존 농도가 높아졌다. 시간 경과에 따른 오존의 감소량은 방사선을 조사한 후 10분이 경과된 후부터 background 농도(0.016 ppm/hr)로 변화하였다. 그리고 방사선 치료실 내의 일일 발생하는 오존의 농도는 실내의 오존 허용기준인 0.1 ppm/hr (측정 평균 0.06 ppm/8 hr) 이하이지만, 냄새에 민감한 환자들이 감지할 수 있는 수준인 0.02 ppm/hr 이상의 농도(최대: 0.038 ppm/hr)를 포함하는 것을 확인할 수 있었다. 결 론: 일정한 조건의 변화에 따른 오존 농도를 통하여 실제 치료실 내 오존 발생량은 환자나 작업종사자에 대해 유해한 작용을 미치는 수준은 아니었다. 흔히 오존을 해로운 기체라고 생각하지만 방사선 치료 시 발생되는 미량의 치료실 내 오존은 오히려 병원성 세균이나 바이러스 살균 등의 공기 정화 작용을 함으로써 치료실 내 이로운 오존의 역할을 할 것이라 사료된다.

  • PDF