• 제목/요약/키워드: Hard chromium

검색결과 33건 처리시간 0.024초

크롬 도금한 유압 실린더 로드와 시일 사이의 미끄럼접촉 해석 (Sliding Contact Analysis between Chromium Plated Hydraulic Cylinder Rod and Seals)

  • 박태조;김민규
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권1호
    • /
    • pp.10-15
    • /
    • 2018
  • The hydraulic cylinder seals are used not only to protect leakage of the working fluids but also to prevent incoming of foreign particles into the system. Chromium plating is generally applied to improve corrosion and wear resistance. It has been noticed that sealing surface damage occurs due to the hard foreign/wear particles contained in the hydraulic oil. In this study, a three-bodied sliding contact problem related with a PTFE seal, a spherical particle and chrome-plated steel substrate is modeled to investigate the relations to wear mechanism. Using the nonlinear finite element software, MARC/MENTAT, the deformed shapes, the von Mises and first principal stress distributions with plating thickness were compared. The sealing surface was mainly abraded by hard particles embedded in the seal. The plastic deformation of the steel substrate decreased with thicker plating. Hence it could be more effective to coat the sealing surface of a hydraulic cylinder with a hard material such as TiN, TiC and DLC.

저탄소강의 크롬도금층 형성 및 내식성에 미치는 Na2MoO4 첨가의 영향 (The effect of Na2MoO4 addition on the formation and corrosion resistance of Cr-electroplated layer of low carbon steel)

  • 배기창;김기욱;김주호;이정훈
    • 한국표면공학회지
    • /
    • 제55권1호
    • /
    • pp.18-23
    • /
    • 2022
  • Presence of cracks in electrodeposited hard chromium layer, which provide a path of corrosive media to steel substrate, is a serious issue in metal finishing with chromium electroplating. In this study, we added sodium molybdate in an electrolyte for chromium electroplating bath. 130g/L of sodium molybdate in Sargent bath for chromium electroplating causes a codepostion of molybdenum with chromium in a rage of 0.61 ~ 3.14 wt.%. The co-deposited molybdenum enhances the crystallinity of chromium layer, thus the hardness is slightly decreases by the addition of molybdate in electrolyte. However, due to the co-deposition of molybdenum, a crack-free chromium layer could be electrodeposited. Such crack-free chromium layer shows a significantly improved corrosion resistance.

중소기업 도금공정에서의 6가 크롬 폭로에 관한 연구 (A Study on Worker Exposure to Hexavalent Chromium in Plating 0peration)

  • 정희경;백남원
    • 한국산업보건학회지
    • /
    • 제3권2호
    • /
    • pp.152-165
    • /
    • 1993
  • This study was performed at eleven small-sized plating factories located in Seoul, Incheon, Ansan, and Taejeon from July 21 to October 6, 1992. The major objectives of this study were to evaluate worker exposure to hexavalent chromium and local exhaust ventilation (L.E.V.) systems at the chromium plating operations. The most suitable L.E.V. systems for chromium plating tanks were designed as examples for recommendation to the industry. The results are summarized as follows. The range of chromium plating operations investigated included decorative, hard, and black chromium plating on several kinds of parts. Most of plating tanks were not equipped with proper control methods against emission of hexavalent chromium mists and workers were not wearing appropriate personal protectives. The ariborne hexavalent chromium concentrations showed an approximate lognormal distribution. The geometric means of both personal and area samples were within the Korean and ACGIH standards, $50{\mu}g/m^3$. However, in comparison with the NIOSH criterion, $1{\mu}g/m^3$, the geometric means of personal samples at two factories and the geometric means of area samples at two factories exceeded it. The geometric means of personal and area samples of high exposure groups (above the NIOSH criterion) were 7 and 27 times higher than those of low exposure groups (below the NIOSH criterion), respectively. The L.E.V. systems of high exposure groups were improperly designed, and the factory with the highest exposure level had no L.E.V. systems at all on chemical etching process. Whereas at factories of low exposure groups, mist control methods such as mist suppressants, tank cover, and/or auxillary L.E.V. systems were added to L.E.V systems. The evaluation of L.E.V. systems showed that there was no chromium plating operation satisfying the ACGIH criteria for capture velocity, slot velocity, and exhaust rate simultaneously. To increase performance of L.E.V. systems, it must be designed to minimize the impact of boundary layer separation. Push-pull ventilation hood and downward plenum ventilation hood were suggested for the Korean industry.

  • PDF

진공 브레이징을 이용한 다이아몬드와 Ni계 페이스트의 계면 거동 연구 (Study on the interfacial reaction vacuum brazed junction between diamond and Ni-based brazing filler metal)

  • 이장훈;이영섭;임철호;이지환;송민석;지원호;함종오
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.48-50
    • /
    • 2005
  • Advanced hard materials based on diamond are in common use. In this study our main goal was employed to analyze, the mechanisms for the rich phases and chromium carbide, interface of a diamond grits brazed to a Ni-based brazing filler metal matrix. When Ni-7Cr-3Fe-3B-4Si (wt. %) was utilized as the brazing alloy, an isothermal holding resulted in the various products(Ni-rich/Cr-rich domains, carbide). According to these results, the chemical compounds and chromium carbides products is considered to play an important role in brazing temperature and time. Especially chromium carbide has an influence on brazing junction properties.

  • PDF

전해 크롬도금 대체용으로서의 CrC 스퍼터링에 관한 연구 (A study of CrC Sputtering as an Alternative Method for Cr Electroplating)

  • 임종민;최균석;이종무
    • 한국재료학회지
    • /
    • 제12권1호
    • /
    • pp.82-88
    • /
    • 2002
  • Chromium carbide films were deposited on high speed steels using a Cr_3C_2$ target by magnetron sputtering. Effects of the deposition parameters (power, Ar pressure and substrate temperature) on deposition rates and surface roughnesses of the films were investigated. The morphologies of those films were characterized by scanning electron microscopy and atomic force microscopy. The grain size of the samples deposited using dc-power is larger than that using equivalent rf-power. The hardness of the sample increases with increasing rf-power, whereas the elastic modulus nearly does not change with rf-power. The optimum sputter deposition conditions for chromium carbide on high speed steels in the corrosion resistance aspect were found to be the rf-power with small roughness.

FE ANALYSIS OF INTERFACIAL BEHAVIOR OF COLD FORGING TOOL COATED BY HARD FILM

  • HAYAKAWA Kunio
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 The 8th Asian Symposium on Precision Forging ASPF
    • /
    • pp.18-21
    • /
    • 2003
  • A behavior of interface of cold forging tool coated by hard film is analyzed by FEM. The indentation of a hemispherical tool of SUJ2 in JIS coated by electroplated coating of chromium into a cylindrical workpiece of S25C in JIS is performed. The proposed constitutive equations are implemented by the non-linear springs model at the interface. Calculated results show that the maximum interfacial normal displacement is observed at an immediately forward from the lip of the indentation, whereas maximum interfacial tangential displacement is at the immediately backward of the lip of the indentation.

  • PDF

Microstructures and hardness of model niobium-based chromium-rich cast alloys

  • Berthod, Patrice;Ritouet-Leglise, Melissa
    • Advances in materials Research
    • /
    • 제7권1호
    • /
    • pp.17-28
    • /
    • 2018
  • Niobium is a candidate base for new alloys devoted to applications at especially elevated temperatures. Elaborating and shaping niobium-based alloys by conventional foundry may lead to mechanically interesting microstructures. In this work a series of charges constituted of pure elements were subjected to high frequency induction melting in cold crucible to try obtaining cast highly refractory Nb-xCr and Nb-xCr-0.4 wt.%Calloys(x=27, 34 and 37 wt.%). Melting and solidification were successfully achieved. The as-cast microstructures of the obtained alloys were characterized by electron microscopy and X-ray diffraction and their hardness were specified by Vickers macro-indentation. The obtained as-cast microstructures are composed of a body centered cubic (bcc) niobium dendritic matrix and of an interdendritic eutectic compound involving the bcc Nb phase and a $NbCr_2$ Laves phase. The obtained alloys are hard to cut and particularly brittle at room temperature. Hardness is of a high level (higher than 600Hv) and is directly driven by the chromium content or the amount of {bcc Nb - $NbCr_2$} eutectic compound. Adding 0.4 wt.% of carbon did not lead to carbides but tends to increase hardness.

고경도강(AISI 4140, HrC60)의 하드터닝에서 가공속도 및 윤활조건 변경에 따른 CBN 공구의 마모 특성 (Wear Characteristics of CBN Tools on Hard Turning of AISI 4140)

  • 양기동;박경희;이명규;이동윤
    • 한국정밀공학회지
    • /
    • 제31권9호
    • /
    • pp.799-804
    • /
    • 2014
  • Hard turning is a machining process for hardened materials with high surface quality so that grinding process can be eliminated. Therefore, the hard turning is capable of reducing machining time and improving productivity. In this study, hardened AISI4140 (high-carbon chromium steel) that has excellent yield strength, toughness and wear resistance was finish turned using CBN tools. Wear characteristics of CBN tool was analyzed in dry and MQL mixed with nano-particle (Nano-MQL). The dominant fracture mechanism of CBN tool is diffusion and dissolution wear on the rake surface resulting in thinner cutting edge. Abrasive wear by hard inclusion in AISI4140 was dominant on the flank surface. Nano-MQL reduced tool wear comparing with the dry machining but chip evacuation should be considered. A cryogenically treated tool showed promising result in tool wear.