• Title/Summary/Keyword: Hands Free

Search Result 163, Processing Time 0.027 seconds

A Study on the Design of Integrated Speech Enhancement System for Hands-Free Mobile Radiotelephony in a Car

  • Park, Kyu-Sik;Oh, Sang-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2E
    • /
    • pp.45-52
    • /
    • 1999
  • This paper presents the integrated speech enhancement system for hands-free mobile communication. The proposed integrated system incorporates both acoustic echo cancellation and engine noise reduction device to provide signal enhancement of desired speech signal from the echoed plus noisy environments. To implement the system, a delayless subband adaptive structure is used for acoustic echo cancellation operation. The NLMS based adaptive noise canceller then applied to the residual echo removed noisy signal to achieve the selective engine noise attenuation in dominant frequency component. Two sets of computer simulations are conducted to demonstrate the effectiveness of the system; one for the fixed acoustical environment condition, the other for the robustness of the system in which, more realistic situation, the acoustic transmission environment change. Simulation results confirm the system performance of 20-25dB ERLE in acoustic echo cancellation and 9-19 dB engine noise attenuation in dominant frequency component for both cases.

  • PDF

Design Adaptive Acoustic Echo Canceller for AVRCP Bluetooth Hands Free (AVRCP 기반의 블루투스 핸즈프리를 위한 음향반향제거기 설계)

  • Jung, Yong-Gyu;Kim, Kyeong-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.33-38
    • /
    • 2009
  • Recently most of A/V devices are being adopted hi-tech of A VRCP and changed to mobile environment. AVRCP is designed to provide a standard interface to control A/V devices, hi-fi equipment, or others to allow a single remote control or other device to control all the A/V equipment to which a user has access. It may be used in concert with A2DP or VDP. The AVRCP defines two roles, that of a controller and target device. In AVRCP, the controller translates the detected user action to the A/V control signal, and then transmits it to a remote Bluetooth enabled device. It can be small and mixed mobile devices using bluetooth technologies. The functions available for a conventional infrared remote controller can be realized in this protocol. The remote control described in this protocol is designed specifically for A/V control only. We designed new DSP using Adaptive Acoustic Echo Canceller for bluetooth hands free based this AVRCP standard specifications.

  • PDF

A Study on the Multi-Modal Browsing System by Integration of Browsers Using lava RMI (자바 RMI를 이용한 브라우저 통합에 의한 멀티-모달 브라우징 시스템에 관한 연구)

  • Jang Joonsik;Yoon Jaeseog;Kim Gukboh
    • Journal of Internet Computing and Services
    • /
    • v.6 no.1
    • /
    • pp.95-103
    • /
    • 2005
  • Recently researches about multi-modal system has been studied widely and actively, Such multi-modal systems are enable to increase possibility of HCI(Human-computer Interaction) realization, enable to provide information in various ways and also enable to be applicable in e-business application, If ideal multi-modal system can be realized in future, eventually user can maximize interactive usability between information instrument and men in hands-free and eyes-free, In this paper, a new multi-modal browsing system using Java RMI as communication interface, which integrated by HTML browser and voice browser is suggested and also English-English dictionary search application system is implemented as example.

  • PDF

Reconstruction of the Defects of the Hands with Arterialized Venous Free Flap (유리 동맥화 정맥 피판을 이용한 수부 결손의 재건)

  • Kim, Joo-Sung;Kim, Jin-Ho
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.2
    • /
    • pp.139-148
    • /
    • 1999
  • Since Nakayama's first report about venous flap, many experimental and clinical studies were done about this new type of flap. And due to its various benefits, its applications as arterialized venous free flap type have increased recently. In this study we have attempted to reconstruct composite of defects of the hand with new modification of arterialized venous free flap and simultaneous reconstruction of skin, nerve, tendon were performed successfully. From 1994 to 1999, the defects of the hands in 35 patients were reconstructed with various modifications of arterialized venous free flaps. The range of age was from 19 to 55 years and size of flap ranged from $1{\times}2cm\;to\;14{\times}9cm$. Among them, 12 cases of flap over 20cm in size were included. Indications of flaps were as follows: resurfacing of the defects of the skin (9 cases), simultaneous reconstruction of extensor, skin and digital nerve(2 cases), reconstruction of the skin with extensor(5 cases), as a flap-through type vascular reconstruction(6 cases), for digital nerve reconstruction(2 cases), contracture release(3 cases), and finger tip reconstruction(9 cases). All of the cases except one survived with marginal skin necrosis less than 10%. And relatively large flaps over 20cm in size successfully survived without any delay procedures. Composite reconstructions including tendon and nerve were successful with new modifications of this flap. Arterialized venous free flap is one of the useful procedure in reconstruction of the hand because it has many advantages such as non-bulky and good quality of flap, variable length of pedicle, preservation of major vascular pedicle, less operation time, single operative field and in addition possibility of various modifications.

  • PDF

Comparison of Biomechanical Stress on Low Back(L5/S1) for One-hand and Two-hands Lowering Activity

  • Kim, Hong-Ki
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.413-420
    • /
    • 2013
  • Objective: The objective of this study was to compare one-hand and two-hands lowering activity in terms of biomechanical stress for the range of lowering heights from knuckle height to 10cm above floor level. Background: Even though two-hands lifting/lowering activity of manual materials handling tasks are prevalent at the industrial site, many manual materials handling tasks which require the worker to perform one-hand lifting/lowering are also very common at the industrial site and forestry and farming. Method: Eight male subjects were asked to perform lowering tasks using both a one-handed as well as a two-handed lowering technique. Trunk muscle electromyographic activity was recorded while the subjects performed the lowering tasks. This information was used as input to an EMG-assisted free-dynamic biomechanical model that predicted spinal loading in three dimensions. Results: It was shown that for the left-hand lowering tasks, the values of moment, lateral shear force, A-P shear force, and compressive force were increased by the average 6%, as the workload was increased twice from 7.5kg to 15kg. For the right-hand lowering task, these were increased by the average 17%. For the two-hands lowering tasks, these were increased by the average 14%. Conclusion: Even though the effect of workload on the biomechanical stress for both one-hand and two-hands lowering tasks is not so significant for the workload less than 15kg, it can be claimed that the biomechanical stress for one-hand lowering is greater than for two-hands lowering tasks. Therefore, it can be concluded that asymmetrical lowering posture would give greater influence on the biomechanical stress than the workload effect for one-hand lowering activity. Application: The result of this study may be used to provide guidelines of recommended safe weights for tasks involved in one-hand lowering activity.

A Numerical Analysis of the Behavior of the Free Surface in a Moving Cup (이송되는 컵 내부의 자유 표면의 거동 특성에 대한 수치해석)

  • Hong, Tae-Hyub;Chae, Hee-Moon;Kim, Chyang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2997-3002
    • /
    • 2007
  • A manipulator is operated for the motion of mechanical hands or arms by mechanical mechanism. When a cup including liquid inside is shifted by a manipulator, it is important to know how a free surface of the liquid moves. In this study, non-dimensional parameters have been found that affect the rise of the free surface in a cup moving with constant acceleration. The non-dimensional parameters are the dimensionless time, the ratio of inertia effect to vicous effect (Reynolds number), aspect ratio of the liquid inside the cup and acceleration ratio (Froude number). Through this study, the height of the free surface rise in a cup has been predicted. Generally the maximum rise of the free surface is dependent on the Reynolds number and Froude number strongly, but on the aspect ratio weakly. But the influence of the aspect ratio on the maximum rise of the free surface in not negligible in the range 10 < Re < 100.

  • PDF

Staged Reconstruction of the Mangled Hand with the Combined Use of Pedicled Groin Flap and Free Wrap Around Flap (광범위 수부 손상에서 서혜부 유경피판과 유리 포장주위피판을 이용한 단계적 무지 재건술)

  • Roh, Young-Hak;Chung, Moon-Sang;Baek, Goo-Hyun;Lee, Young-Ho;Gong, Hyun-Sik;Rhee, Seung-Hwan;Lee, Ye-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.62-66
    • /
    • 2009
  • Purpose: Despite the free tissue transfer using microsurgical technique being the current trend of soft tissue reconstruction of the hand, the pedicled groin flap has the advantage to provide coverage for the mangled hand without necessitating the use of a damaged arterial system and also providing the benefit of saving the arterial system for later free tissue transfer. This report presents the author's experience using pedicled groin flap in four cases of mangled hands with massive bone and soft tissue defects requiring later thumb reconstruction with the free wrap around flap. Materials and methods: The patients' age ranged from 30 to 51 years; three patients were male and one was female. The causes of mangled hand included two machinery crush injuries, one laboratory explosion and one motor vehicle accident. While evaluating the post-operative results, factors like flap survival, complications, stability in opposition, pinch power and 2 point discrimination were taken into account. Results: All massive soft tissue defects of the hands were completely covered with pedicled groin flap successfully. The reconstructed thumb using free wrap around flap did not have any limitation in opposition. There was no occurrence of post-operative infection and all the flaps survived completely. The average pinch power was 70% of the contralateral intact thumb and average 2 point discrimination was 10 mm. Conclusion: The pedicled groin flap for the reconstruction of the massive soft tissue defects of the hand with subsequent reconstruction of the thumb with a wrap around flap is a very useful procedure. The combined use of pedicled groin flap and wrap around flap allows adequate coverage of sizable soft tissue defects and functional thumb opposition in cases of reconstruction of the mangled hands.

  • PDF

Comparison of Biomechanical Stress on Low Back(L5/S1) for One-hand Lifting and Lowering Activity (한 손 들기 작업과 내리기 작업의 요추부위(L5/S1) 부하에 대한 비교 연구)

  • Kim, Hong-Ki
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.72-81
    • /
    • 2014
  • Even though two-hands lifting/lowering activity of manual materials handling tasks are prevalent at the industrial site, many manual materials handling tasks which require the worker to perform one-hand lifting/lowering are also very common at the industrial site, forestry, farming, and daily life. The objective of this study was to compare one-hand lowering activity to lifting activity in terms of biomechanical stress for the range of lowering heights from knuckle height to 10cm above floor level with two workload 7.5kg and 15.0kg. Eight male subjects with LMM were asked to perform lifting/lowering tasks using both a one-handed (left-hand and right-hand) as well as a two-handed technique. Spinal loading was estimated through an EMG-assisted free-dynamic biomechanical model. The biomechanical stress of one-hand lowering activity was shown to be 43% lower than that of one-hand lifting activity. It was claimed that the biomechanical stress for one-hand lifting/lowering activity is almost twice (194%) of the one for two-hands lifting/lowering activity. It was also found that biomechanical stress by one-hand lowering/lifting activity with the half workload of two-hands lowering/lifting activity was greater than that of the two-hands lowering/lifting activity. Therefore, it might be a risk to consider the RWL of one-hand lowering/lifting activity to simply be a half of the RWL of two-hands lowering/lifting activity recommended by NIOSH.

Effect of 8% lidocaine spray on the sensory and pain thresholds of the skin of the face and hands evaluated by quantitative sensory testing

  • Okayasu, Ichiro;Komiyama, Osamu;Ayuse, Takao;De Laat, Antoon
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.6
    • /
    • pp.361-365
    • /
    • 2018
  • Background: Recently, we examined the effects of 2% lidocaine gel on the tactile sensory and pain thresholds of the face, tongue and hands of symptom-free individuals using quantitative sensory testing (QST); its effect was less on the skin of the face and hands than on the tongue. Consequently, instead of 2% lidocaine gel, we examined the effect of 8% lidocaine spray on the tactile sensory and pain thresholds of the skin of the face and hands of healthy volunteers. Methods: Using Semmes-Weinstein monofilaments, QST of the skin of the cheek and palm (thenar skin) was performed in 20 healthy volunteers. In each participant, two topical sprays were applied. On one side, 0.2 mL of 8% lidocaine pump spray was applied, and on the other side, 0.2 mL of saline pump spray was applied as control. In each participant, QST was performed before and 15 min after each application. Pain intensity was measured using a numeric rating scale (NRS). Results: Both the tactile detection threshold and filament-prick pain detection threshold of the cheek and thenar skin increased significantly after lidocaine application. A significant difference between the effect of lidocaine and saline applications was found on the filament-prick pain detection threshold only. NRS of the cheek skin and thenar skin decreased after application of lidocaine, and not after application of saline. Conclusion: The significant effect of applying an 8% lidocaine spray on the sensory and pain thresholds of the skin of the face and hands can be objectively scored using QST.

A Design of Multi-channel Speech Pickup Embedded System for Hands-free Comuunication (핸즈프리 통신을 위한 다중채널 음성픽업 임베디드 시스템 설계)

  • Ju, Hyng-Jun;Park, Chan-Sub;Jeon, Jae-Kuk;Kim, Ki-Man
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.2
    • /
    • pp.366-373
    • /
    • 2007
  • In this paper we propose a multi-channel speech pickup system for calling quality enhancement of hands-free communication using ALTERA Nios-II processor. Multi-channel speech pickup system uses Delay-and-Sum beamformer with zero-padding interpolator. This paper implements speech pickup system using the Nios-II processor with real-time I/O data processing speed. The proposes speech pickup embedded system shows a good agreement with those of computer simulation(MATLAB) and conventional DSP processor(TMS320C6711) result. The proposed method is effective more than previous methods in cost and design processing time. As a result, LE(Logic Element) of hardware used 3,649/5,980(61%) on a chip.