The Analysis of the Effect of the Vibration-proof Handle Used for the Reduction of Hand-transmitted Vibration (수전달 진동 저감을 위한 방진 핸들의 효과 분석)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.146-149
    • /
    • 2005
  • Thesedays, the reduction of hand-transmitted vibration of hand-held power tools is important issue for operators' welfare, In the study, frequency response function is measured and vibration total value is evaluated for solving the principle and effect of the BOSCH's vibration-proof handle. This handle functions as a dynamic damper and has the effect, 22% vibration total value reduction under idling condition using a system that consists of a PC with data acquisition system and LabVIEW program. The program in the system makes it possible to evaluate vibration total value according to ISO 5349. This handle offers a good example for figuring out the physical contradiction between the work efficiency and operators' health.

  • PDF

Optimization of Handle Vibration of Walking-type Cultivator (보행형 관리기 핸들의 진동 최적화)

  • Park S.B.;Park Y.J.;Kim K.U.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.139-145
    • /
    • 2006
  • A previous study showed that the handle vibration of a walking type cultivator can be reduced by adding a mass to the handle. This study was conducted to determine the optimum magnitude and location of the mass to be added for the same cultivator. The possible locations of added mass were determined by investigating nodal points of the handle vibration by an ODS (operational deflection shapes) test at an engine frequency of 52 Hz. The optimum location was then determined as one that moved the nodal points to the hand grip of the handle bar. To determine the optimum magnitude of the mass, the possible locations were added by a mass from 0.2 to 2.0 kg in an increment of 0.2 kg. The optimum magnitude was then determined as a mass which minimized the vibration level at the hand grip. For the case of this study, the z-axis vibration at the hand grip was reduced from $2.67m/s^2\;to\;0.88m/s^2$ resulting in a reduction of 67% and the total vibration from $4.09m/s^2\;to\;3.27m/s^2$ resulting in a 20% reduction by adding an optimum mass to the optimum location.

Study on Vibration Characteristic Improvement of Aircraft Landing Gear Handle (항공기용 착륙장치 핸들의 진동 특성 개선에 관한 연구)

  • Kang, Gu Heon;Ahn, Jong Moo
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.2
    • /
    • pp.59-65
    • /
    • 2018
  • The landing gear (L/G) handle of an aircraft is an essential piece of equipment for aircraft take-off and landing. The bracket in the landing gear handle was fractured during a vibration test when developing the landing gear handle. This paper summarizes the vibration test procedures performed during landing gear handle development. A cause analysis, design improvements, and verification results of the fault in the vibration test are also provided.

Measurement of Grip and Feed Force in the Evaluation of Hand-arm Vibration (수완계 진동 평가에 영향을 미치는 작용력의 측정)

  • 최석현;장한기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1038-1042
    • /
    • 2003
  • In order to evaluate dynamic impedance of a hand-arm system it is necessary to measure the hand-transmitted vibration and the reaction force at the same time while gripping the vibrating handle. In the study a device was developed to measure both the vibration and the force. The device consists of a measurement handle with four strain gauge and two accelerometers and a PC based control system with a program for the signal processing and evaluation of the hand-transmitted vibration and reaction force. The handle was installed on the vibration shaker so that it can move by the generated signal from the control system. As an application of the system dynamic reaction force and the frequency weighted acceleration at the handle attached to the shaker were measured at various grip force and feed force. This system will be very useful in the area of impedance measurement and the evaluation of performance of anti-vibration gloves.

  • PDF

Vibration Reduction of Walking-type Cultivator's Handle using Modal Analysis and Operational Deflection Shapes Techniques (모드 해석과 운전 중 변형 형상 기법을 이용한 보행형 관리기의 핸들 진동 감소 방안)

  • 박영준;이윤세;김경욱
    • Journal of Biosystems Engineering
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2004
  • The objectives of this study were to determine the natural frequency of a walking-type cultivator's handle using a modal analysis, to determine whether or not the handle resonates with forcing frequency induced by its engine, and to determine a method to reduce the handle vibration using a technique of the operational deflection shapes(ODS). Results of the study are as follows: The natural frequencies of the handle up to third harmonics were found to be 20.4, 22.5 and 92.1 Hz in the vertical direction and 14.9, 93, and 132 Hz in the horizontal direction. It was found that the handle does not resonate with the forcing frequency of the engine, which is 52 Hz. The operational deflection shape analysis revealed the deflected shapes of the handle in the vertical and horizontal directions and suggested that the handle vibration can be reduced by adding some mass to the place where the largest deflection occurs. Attaching of 1.1 kg mass adjacent to the largely deflected area resulted in reductions of vibration from 9.45 to 8.03 m/s$^2$ in x-axis direction from 3.89 to 3.16 m/s$^2$ in y-axis direction and from 7.89 to 3.09 m/s$^2$ in z-axis direction, which are respectively 15, 19 and 61% reductions. The total vibration level was reduced by 29%, indicating that mass-adding method by the ODS is very effective for reducing the handle vibrations of the cultivators.

Simultaneous Measurement of Vibration and Applied Forces at a Power Tool Handle for the Reduction of Random Error When valuating Hand-transmitted Vibration (수전달 진동평가량의 랜덤오차 저감을 위한 공구 핸들에서의 진동과 작용력의 동시 측정)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.404-411
    • /
    • 2005
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure the grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with a data acquisition system and the corresponding software. Strain gauges and an accelerometer were mounted on the handle surface for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root-mean-square accelerations at the handle, obtained in repetition for each power tool with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce random error of the measured vibration.

The Simultaneous Measurement of Vibration and Applied forces at a Power tool handle for the Evaluation of Hand-transmitted Vibration (수전달 진동 평가를 위한 공구 핸들에서의 진동과 작용력의 동시 측정)

  • Choi, Seok-Hyun;Jang, Han-Kee;Park, Tae-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.689-694
    • /
    • 2004
  • To increase accurateness and reliability of the evaluation of power tool vibration transmitted to an operator, it is necessary to measure grip and feed forces during the measurement of hand-transmitted vibration. In the study a system was invented to measure the vibration and the grip and/or feed force, which consists of a measurement handle and a PC with data acquisition system and the software. Strain gauges and an accelerometer were mounted on the handle for the simultaneous measurement of the forces and the vibration. The program in the system makes it possible to monitor the grip and feed force during the tool operation so that the operator keeps the applying forces within the pre-determined range. Investigating the vibration total values, frequency-weighted root mean square accelerations at the handle, obtained at various conditions with control of the grip and feed force showed more consistency than those measured without force control. By using the system the experimenter can reduce uncertainty of the measured vibration.

  • PDF

Measurement of the hand-transmitted vibration using a miniature 3-axes accelerometer (초소형 3축 가속도계를 이용한 수전달 진동 측정에 관한 연구)

  • 송치문;장한기;김승한;채장범
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1043-1047
    • /
    • 2003
  • Most of the measurement and the evaluation of hand-transmitted vibration have been performed by using a small size single axis accelerometer between the handle and the hand palm or a three axis accelerometer attached on an adapter outside the hand(indirect measurement). It is most desirable for the correct evaluation of hand-transmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm in the three axis(direct measurement) as recommended in ISO 5349-1. In the study three axes acceleration measurement device was developed of which the thickness was less than 7mm so that it can be placed between the handle and the palm without any inconvenience during the measurement. To verify the performance of the developed device, measured acceleration by the two methods, direct and indirect, were compared in the study.

  • PDF

Vibration Characteristics of a Motorcycle Body (이륜차 차체의 진동특성)

  • 박보용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.1
    • /
    • pp.169-176
    • /
    • 1998
  • This paper presents the vibration characteristics of a motorcycle body frame. In order to study the excitation mechanism. for example, of handle vibration, discrete models and finite element model are developed for the calculation of natural frequencies and mode shapes of the driveline and body. which can lead to the resonances. Experiments are also conducted to compare with the analytical results From the various kinds of vibration reduction methods, the technical realizable one is presented to reduce the handle vibration responses at the start of driving.

  • PDF

Development of the System for Measurement of the Vibration Transmissibility of an Anti-vibration Glove (방진 장갑 진동 전달률 측정 시스템 개발)

  • Choi, Seok-Hyun;Hong, Seok-In;Jang, Han-Kee;Park, Tae-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.602-608
    • /
    • 2006
  • In order to evaluate performance of anti-vibration gloves, it is necessary to measure the transmitted vibration to the hand and the applied forces at the same time while gripping the vibrating handle. In the study a system was developed to measure both the vibration and the forces. The system consists of a measurement handle with eight strain gauges and two accelerometers and a PC-based system with a software for signal processing and evaluation of the hand-transmitted vibration and for control of applied forces in the pre-determined range. The handle was installed on the vibration shaker which is strong enough so as not to be affected by dynamic coupling with the hand-arm system. Whole procedure of ISO 10819 to determine the vibration transmissibility of anti-vibration gloves was programmed into the system. As an example of the application, three subjects joined the test to get vibration transmissibilities of anti-vibration gloves where each glove was tested twice a subject. Average and standard deviation of vibration transmissibility were also calculated.