• Title/Summary/Keyword: Hand washing

Search Result 379, Processing Time 0.026 seconds

A Study on the Dyeing according to Kinds of Loess (황토 종류에 따른 염색성 연구)

  • 강영의;박순옥
    • Textile Coloration and Finishing
    • /
    • v.15 no.6
    • /
    • pp.39-46
    • /
    • 2003
  • The experiments about dyeing concentration, temperature and time were done using yellow, red and purple loess as natural inorganic dyes in order to verify a degree of dyeing, characteristics of color and fastness. The results were as following; 1. As a result of analyzing components of loess, purple loess was much than other loess in quartz component and coarse particles contained. This affected to the degree of dyeing. 2. The stronger dyeing concentration was, the more the degree of dyeing was improved, and yellow loess containing fine particles was the best in the degree of dyeing. 3. When it was dyed with raising up to $100^\circ{C}$ for 10 minutes after stirring for 20 minutes at $60^\circ{C}$, was better than on starting at $40^\circ{C}$ or $80^\circ{C}$ in the degree of dyeing. Also yellow loess was the best in these experiments. 4. Washing fastness of loess was low such as other natural dyes, but dyeing wasn't transferred to other textiles. On the other hand, light fastness of it was very excellent and rubbing fastness was relatively good as 3~3.5.

SYNERGISTIC SKIN PROPERTY INTERACTIONS BETWEEN ALPHA HYDROXY ACID AND SKIN MOISTURIZER IN A HAND DISHWASHING DETERGENT

  • Brumbaugh, E.H.;Sigler, M.L.;Casterton, P.L.;Dornoff, M.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.491-497
    • /
    • 2003
  • The use of both an Alpha Hydroxy Acid, Citric Acid, and a Skin Moisturizer, Glycereth-26, formulated into a hand dishwashing detergent have been shown to be synergistic in their effects on certain skin health parameters. Each ingredient was evaluated alone and together in a hand dishwashing detergent via a 9-week use test. Panelists washed dishes using the sponge method commonly used in Asian markets and a 1:7 dilution of the concentrated dish detergent. Panelist's hands were evaluated initially and at 3-week intervals for nine weeks. After nine weeks panelist's hands showed significant improvements in Moisture Absorption and Transepidermal Water Loss (TEWL). A synergistic effect on TEWL was found between the AHA and the Moisturizer. These effects, showing an improvement in the condition of the panelist's skin are impressive, particularly since they were observed from a dishwashing product that is highly diluted and at near neutral pH during the washing process.

  • PDF

SYNERGISTIC SKIN PROPERTY INTERACTIONS BETWEEN ALPHA HYDROXY ACID AND SKIN MOISTURIZER IN A HAND DISHWASHING DETERGENT

  • Brumbaugh, E.H.;Sigler, M.L.;Casterton, P.L.;Dornoff, J.M.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.417-423
    • /
    • 2003
  • The use of both an Alpha Hydroxy Acid, Citric Acid, and a Skin Moisturizer, Glycereth-26, formulated into a hand dishwashing detergent have been shown to be synergistic in their effects on certain skin health parameters. Each ingredient was evaluated alone and together in a hand dishwashing detergent via a 9-week use test. Panelists washed dishes using the sponge method commonly used in Asian markets and a 1:7 dilution of the concentrated dish detergent. Panelist's hands were evaluated initially and at 3-week intervals for nine weeks. After nine weeks panelist's hands showed significant improvements in Moisture Absorption and Transepidermal Water Loss (TEWL). A synergistic effect on TEWL was found between the AHA and the Moisturizer. These effects, showing an improvement in the condition of the panelist's skin are impressive, particularly since they were observed from a dishwashing product that is highly diluted and at near neutral pH during the washing process.

  • PDF

Biorisk Assessment of Medical Diagnostic Laboratories in Nigeria

  • Oladeinde, Bankole Henry;Omoregie, Richard;Odia, Ikponmwonsa;Osakue, Eguagie Osareniro;Imade, Odaro Stanley
    • Safety and Health at Work
    • /
    • v.4 no.2
    • /
    • pp.100-104
    • /
    • 2013
  • Background: The aim of this study was to assess public and private medical diagnostic laboratories in Nigeria for the presence of biosafety equipment, devices, and measures. Methods: A total of 80 diagnostic laboratories in biosafety level 3 were assessed for the presence of biosafety equipment, devices, and compliance rate with biosafety practices. A detailed questionnaire and checklist was used to obtain the relevant information from enlisted laboratories. Results: The results showed the presence of an isolated unit for microbiological work, leak-proof working benches, self-closing doors, emergency exits, fire extinguisher(s), autoclaves, and hand washing sinks in 21.3%, 71.3%, 15.0%, 1.3%, 11.3%, 82.5%, and 67.5%, respectively, of all laboratories surveyed. It was observed that public diagnostic laboratories were significantly more likely to have an isolated unit for microbiological work (p = 0.001), hand washing sink (p = 0.003), and an autoclave ($p{\leq}0.001$) than private ones. Routine use of hand gloves, biosafety cabinet, and a first aid box was observed in 35.0%, 20.0%, and 2.5%, respectively, of all laboratories examined. Written standard operating procedures, biosafety manuals, and biohazard signs on door entrances were observed in 6.3%, 1.3%, and 3.8%, respectively, of all audited laboratories. No biosafety officer(s) or records of previous spills, or injuries and accidents, were observed in all diagnostic laboratories studied. Conclusion: In all laboratories (public and private) surveyed, marked deficiencies were observed in the area of administrative control responsible for implementing biosafety. Increased emphasis on provision of biosafety devices and compliance with standard codes of practices issued by relevant authorities is strongly advocated.

The Study on the impact of optimistic bias and control illusion in COVID 19 Preventive Behavior (COVID 19 방역행동에 있어서 낙관적 편견과 통제성 편향의 영향에 관한 연구)

  • Jeong, Hyeonju
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.2
    • /
    • pp.223-233
    • /
    • 2022
  • In addition to optimistic bias which can be a biased phenomenon in perceived susceptibility, including illusion of control which is a distorted phenomenon, the current study attempted to demonstrate the influential relationship between these two important variables and COVID 19 personal preventive behaviors and social distancing practice. Conducting Survey utilizing online pannel from Macromill Embrain, the present study performed regression analysis, setting personal preventive behavioral variables such as mask wearing, hand washing, using hand sanitizer as independent variable, and analyzed how these independent variables influence control illusion and optimistic bias. As a result, COVID 19 personal preventive behavior didn't have direct effect on optimistic bias and control illusion except for hand washing. Finding, also, showed that control illusion affected optimistic bias, and the relation between these variables was different depending on demographic variable such as gender and age.

Eye Irritation Test of Lens Washing Agents as ReNuTM (렌즈 보존액 ReNuTM에 대한 안점막자극시험)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong;Joo, Kyung-Bok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.293-304
    • /
    • 2005
  • As the eye irritant test of lens washing agent, ReNu$^{TM}$ was analysed using Draize methods (1959) according to KFDA Guidelines. In addition, to test the potential toxicity of test articles the ratio of inflammatory cells and non-inflammatory epitheloid cells were also observed using smear cytology methods against ocular discharge. At test, the histopathological changes on the cornea, iris, retina and sclera were also observed in all animals. Slight irritancy of the cornea and conjunctiva were observed at 1, 2 and 3 days after dropping in non-washing group. The Mean Index of Ocular Irritation(MIOI) of these points are detected as 4.17, 3.00 and 1.33, respectively. In washing group, slight irritancy of the cornea and conjunctiva were observed at 1 and 2 days after dropping with MIOI as 0.67 and 1.33, respectively. Therefore, ReNu$^{TM}$ was considered as non-irritating materials because the MIOI is detected below 5.00 throughout the whole experimental periods in both washing and non-washing groups. The Index of Acute Ocular Irritation(IAOI) is also detected as 4.17(1 day after dropping). Except of the somewhat increase trend of the inflammatory cell ratios in ocular discharge at 1 day after dropping of non-washing group, but significances are not detected, on the other hand, no meaningful changes on smear cytology of ocular discharges are observed in this study. In addition, no abnormal histopathological changes on the cornea, iris, retina and sclera were also not detected in ReNu$^{TM}$ dropping group compared to that of non-treated control eyes.

  • PDF

Review on Prevalence, Risk Factors, and Research Advancements on the Use of Medical Gloves Concerning Hand Dermatitis Among Health Care Workers

  • Jeevasunthari Gunasegaran;Ying-Ying Teh;Chin-Keong Lim;Shiow-Fern Ng
    • Safety and Health at Work
    • /
    • v.15 no.2
    • /
    • pp.129-138
    • /
    • 2024
  • The COVID-19 pandemic has led to a significant surge in glove usage, as recommended by the World Health Organization. Despite efforts to ensure the quality and safety of gloves, glove-associated skin diseases such as hand dermatitis have become ubiquitous, particularly among health care workers. This review discusses the prevalence, causes, and risk factors of hand dermatitis, as well as research efforts in medical gloves in the past decade to overcome glove-related hand dermatitis. Research papers from 2013 to 2022 were reviewed, selecting only 49 relevant papers from the Ovid, PubMed, and Scopus databases. The average prevalence of hand dermatitis among health care workers increased from 21.08% to 37.24% upon the impact of the COVID-19 pandemic. The cases are likely due to allergies to latex proteins, rubber additives, and accelerators commonly found in gloves. Using alternatives to latex gloves, such as accelerator-free and latex-free glove options, can help reduce allergy-induced hand dermatitis. Strict hand hygiene practices, such as frequent hand washing and the use of sanitizers, are also contributing factors in contracting hand dermatitis. Over the past decade, glove research advancements have focused mainly on reducing or immobilizing latex proteins. These include the use of biodegradable dialdehyde, sodium alginate, arctigenin, bromelain, papain, UV-LED, prototype photoreactors, and structure-modified nanosilica with silane A174. Two effective hand dermatitis preventive measures, i.e. an additional layer of glove liners and the use of gentle alcohol-based hand sanitizer, were recommended. These advancements represent promising steps towards mitigating hand dermatitis risks associated with glove usage.

Distribution of Foreign Mineral Materials and Heavy Metals Contained in Herbal Medicines, and Effect of Washing (한약재에 함유된 광물성이물과 중금속의 분포 및 수세효과)

  • Kim, Dong-Gyu;Kim, Kyung-Sik;Lee, Sung-Deuk;Jo, Sung-Ae;Lee, Hyun-Kyoung;Jung, Sun-Ok;Jung, Kweon;Park, Seung-Kook
    • Korean Journal of Pharmacognosy
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2014
  • This study was conducted to investigate the content of foreign mineral materials and heavy metals (Pb, As, Cd, Hg) contained in commercial herbal medicines (1504 samples) classified by parts used, and the effect of removing heavy metals by washing treatment (take 50 g of the sample and put 1000 ml of distilled water, shake it gentle by hand for 1 min). The 5% trimmed means of acid-insoluble ash value (%) were as follows; above ground parts (0.76) and underground parts (0.52). Those of the total amount of individual heavy metals value (mg/kg) were as follows; caulis (1.33), flos (1.23), herba (0.91), cortex (0.76), rhizoma (0.73), radix (0.67), semen (0.44) and fructus (0.39). Acid-insoluble ash content was correlated with Pb in herbal medicines of underground parts (r=0.446) (p<0.01). After washing, the removal rate of heavy metals contained in 6 radix herbal medicines shows 33-13% respectively.

Surface Treatment Method for Long-term Stability of CdSe/ZnS Quantum Dots (장시간 안정성을 위한 CdSe/ZnS 양자점의 표면처리 기술)

  • Park, Hyun-Su;Jeong, Da-Woon;Kim, Bum-Sung;Joo, So-Yeong;Lee, Chan-Gi;Kim, Woo-Byoung
    • Journal of Powder Materials
    • /
    • v.24 no.1
    • /
    • pp.1-5
    • /
    • 2017
  • We have investigated the washing method of as-synthesized CdSe/ZnS core/shell structure quantum dots (QDs) and the effective surface passivation method of the washed QDs using PMMA. The quantum yield (QY%) of as-synthesized QDs decreases with time, from 79.3% to 21.1%, owing to surface reaction with residual organics. The decreased QY% is restored to the QY% of as-synthesized QDs by washing. However, the QY% of washed QDs also decreases with time, owing to the absence of surface passivation layer. On the other hand, the PMMA-treated QDs maintained a relatively higher QY% after washing than that of the washed QDs that were kept in toluene solution for 30 days. Formation of the PMMA coating layer on CdSe/ZnS QD surface is confirmed by HR-TEM and FT-IR. It is found that the PMMA surface coating, when combined with washing, is useful to be applied in the storage of QDs, owing to its long-term stability.

Electrostatic Characteristics of the Washer-dryer Combination under Various Drying Conditions (건조 일체형 드럼세탁기의 건조 조건에 따른 정전기 특성)

  • Chung Seung-Eun;Park Chung-Hee;Yun Chang-Sang
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.5 s.153
    • /
    • pp.753-761
    • /
    • 2006
  • This paper suggests the optimal conditions for the laundry to prevent from the electrostatic charge by the evaluation of the electrostatic characteristics in the full process of washing and drying. Cotton, nylon, and polyester fabrics were used as test washing specimens. Detergent and softener were used under the standard washing cycle, and then the electrostatic characteristics of laundry were measured. The results showed that the moisture regain decreased and the electrostatic charge increased with the drying time. It was observed that the specimen fabrics were already dried up before the standard drying cycle was finished. Consequently, the excessive drying caused a generation of electrostatic charge due to the removal of the trace of moisture remaining and the excessive friction. Especially, the softener played an important role to prevent from a generation of electrostatic charge, whose insertion was more effective in the drying than in the rinsing process. It was also shown that the electrostatic charge could be decreased by drying the fabrics of one kind. On the other hand, for drying the mixed kinds of fabrics, the electrostatic charge increased remarkably. Therefore we suggest that the laundry be classified according to the kinds of fiber, and then be washed and dried before excessive drying to reduce electrostatic charge And further, a proper use of softener is effective to reduce electrostatic charge.