• Title/Summary/Keyword: Hall technique

Search Result 155, Processing Time 0.02 seconds

THE STAINLESS STEEL CROWN RESTORATION OF CARIOUS PRIMARY MOLARS WITH HALL TECHNIQUE : A CASE REPORT (Hall technique을 이용한 우식 유구치의 기성 금속관 수복 : 증례보고)

  • Yu, Seong-Goo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.199-205
    • /
    • 2012
  • Although the stainless steel crowns have been recognized as the most effective and durable form of restoration for primary molars, they have been regarded by many dentists as having definite demerits such as invasive nature of procedural complexity and behavioral aspects of children. As an alternative to conventional technique of stainless steel crown restoration, the Hall technique was first introduced in 1988, which is characterized by just pushing the pre-contoured, cement filled crown form onto the abutment molar with no local anesthesia, no caries removal, no tooth preparation. According to several reports, this can slow, arrest, or even reverse the progress of caries. In addition, its atraumatic feature gives less discomfort and stress to children than conventional one, which is thought excellent especially in younger children. Also, It has been reported to be effective and acceptable to dentist, child patients and their parents. In this case study, three children with age of 4 years 5 months, 4 years 10 months, 6 years 4 months were treated with stainless steel crowns using Hall technique on first primary molar respectively. The teeth were free from pulpal, periapical pathology. After follow up of about 3 to 6 months period, the results showed clinically successful outcomes without any marked complication in pulp, tooth or soft tissue till now. But, it should be kept in mind that this technique is not proper to every child, every carious molar, or every dentist. Thorough distinction of indicated cases and continuous follow-up check is highly required. Conclusively, Hall technique might be an effective and realistic minimally invasive alternative for the carious primary molars especially in younger or disabled children, despite potential doubts on its efficacy and some definite limitations.

A Design Of Cross-Shpaed CMOS Hall Plate And Offset, 1/f Noise Cancelation Technique Based Hall Sensor Signal Process System (십자형 CMOS 홀 플레이트 및 오프셋, 1/f 잡음 제거 기술 기반 자기센서 신호처리시스템 설계)

  • Hur, Yong-Ki;Jung, Won-Jae;Lee, Ji-Hun;Nam, Kyu-Hyun;Yoo, Dong-Gyun;Yoon, Sang-Gu;Min, Chang-Gi;Park, Jun-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.152-159
    • /
    • 2016
  • This paper describes an offset and 1/f noise cancellation technique based hall sensor signal processor. The hall sensor outputs a hall voltage from the input magnetic field, which direction is orthogonal to hall plate. The two major elements to complete the hall sensor operation are: the one is a hall sensor to generate hall voltage from input magentic field, and the other one is a hall signal process system to cancel the offset and 1/f noise of hall signal. The proposed hall sensor splits the hall signal and unwanted signals(i.e. offset and 1/f noise) using a spinning current biasing technique and chopper stabilizer. The hall signal converted to 100 kHz and unwanted signals stay around DC frequency pass through chopper stabilizer. The unwanted signals are bloked by highpass filter which, 60 kHz cut off freqyency. Therefore only pure hall signal is enter the ADC(analog to dogital converter) for digitalize. The hall signal and unwanted signal at the output of an amplifer and highpass filter, which increase the power level of hall signal and cancel the unwanted signals are -53.9 dBm @ 100 kHz and -101.3 dBm @ 10 kHz. The ADC output of hall sensor signal process system has -5.0 dBm hall signal at 100 kHz frequency and -55.0 dBm unwanted signals at 10 kHz frequency.

Daeungbojeon Hall of Bulyeongsa Temple, Uljin and the Architectural Technique of the Features (울진 불영사(佛影寺) 대웅보전(大雄寶殿)의 특징(特徵)과 건축술(建築術))

  • Oh, Se-deok
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.1
    • /
    • pp.46-65
    • /
    • 2014
  • This study, under the title of Daeungbojeon Hall of Bulyeongsa Temple, Uljin and the architectural technique of the architect, aimed to make a comprehensive speculation on Daeungbojeon Hall of Bulyeongsa Temple whose accurate construction year was confirmed in 1725. While existing studies dealt with it separately between construction and Buddhist art history this study attempted to sort out it in one perspective by means of comparison with compatible objects in the area. The results are as follows. 1st, by means of comparison of wall painting of Daeungbojeon Hall of Bulyeongsa Temple and other wall paintings of Gyeongsang-do Province, it was estimated to be created before and after 1725, the founding year of the building. 2nd, the stylobate of Daeungbojeon Hall is the only and unique case that Guibu was supported by the bottom. Such stylobate was estimated to be built in the early period of Goryeo stylobate of PostLintel Construction which was more simplified than that of the traditional unified Silla period considering specific techniques. Lastly, by means of comparison of the architectural technique of Daeungbojeon Hall of Bulyeongsa Temple with other temples in Gyeongsang-do Province, the characteristics of the building were found. In particular, the same architectural technique was confirmed by direct comparison of style with Yeongsanjeon Hall of Tongdosa Temple in 1714 which was constructed by the same architect.

Magnetic Characteristics of an InSb Hall Device of Multilayerd Structure (다충구조 InSb 홀소자의 제작과 특성)

  • 이우선;김상용;서용진;박진성;김창일
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.8
    • /
    • pp.681-687
    • /
    • 2000
  • Magnetic Characteristics of an InSb hall device of multilayered structures were investigated. For the measurement of electrical properties of the hall device InSb thin films fabricated with series and parallel multilayers wee evaporated. Hall coefficient hall mobility carrier density and hall voltage were measured as a function of the intensity of magnetic field. We found that the XRD analysis of InSb thin film showed good properties at 20$0^{\circ}C$ 60 minutes. Resistance of ohmic contact was increased linearly due to increasing current. Hall voltages at 0.01 T showed 5$\times$10$^{-4}$ [V] and $1.5\times$10$^{-3}$ [V]. Some of device fabrication technique and analysis of magnetic characteristics were discussed.

  • PDF

Effects of Hall current in a transversely isotropic magnetothermoelastic with and without energy dissipation due to normal force

  • Kumar, Rajneesh;Sharma, Nidhi;Lata, Parveen
    • Structural Engineering and Mechanics
    • /
    • v.57 no.1
    • /
    • pp.91-103
    • /
    • 2016
  • This investigation is concerned with the disturbances in a homogeneous transversely isotropic thermoelastic rotating medium with two temperature, in the presence of the combined effects of Hall currents and magnetic field due to normal force of ramp type. The formulation is applied to the thermoelasticity theories developed by Green-Naghdi Theories of Type-II and Type-III. Laplace and Fourier transform technique is applied to solve the problem. The analytical expressions of displacements, stress components, temperature change and current density components are obtained in the transformed domain. Numerical inversion technique has been applied to obtain the results in the physical domain. Numerically simulated results are depicted graphically to show the effects of Hall current and anisotropy on the resulting quantities. Some special cases are also deduced from the present investigation.

Improvement of a Pound-Drever-Hall Technique to Measure Precisely the Free Spectral Range of a Fabry-Perot Etalon

  • Seo, Dong-Sun;Park, Chongdae;Leaird, Daniel E.;Weiner, Andrew M.
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.357-362
    • /
    • 2015
  • We examine the principle of a modified Pound-Drever-Hall (PDH) technique to measure the free spectral range of a Fabry-Perot etalon (FPE). The FPE's periodic transmission of phase-modulated light allows us to adopt a sampling theorem to develop a new relationship for the PDH error signal. This leads us to find the key parameters governing the measurement accuracy: the phase modulation index ${\beta}$ and the FPE finesse. Without any additional complexity for background noise reduction, we achieve a measurement accuracy of 0.5 ppm. The improvement is mainly attributed to the wide-band phase modulation approaching ${\beta}=10$, and partly to the use of both reflected and transmitted light from the FPE and good FPE finesse.

Hall Effect Characteristics of InSb Thin Film (InSb 박막의 홀효과 특성)

  • Lee, Woo-Sun;Cho, Jun-Ho;Choi, Kun-Woo;Jeong, Yong-Ho;Kim, Sang-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.6-9
    • /
    • 2000
  • InSb hall effect of multilayerd structures were investigated. According to variation of magnetic field measured hall coefficient, Hall mobility, carrier density and hall voltage. For the measurement of electrical properties of hall device, evaperated InSb thin film fabricated with series and parallel multilayers. We found that the XRD analysis of InSb thin film showed good properties at $200^{\circ}C$, 60 minutes. Resistance of ohmic contact increased linearly due to increasing current. Some of device fabrication technique and analysis of Hall effect were discussed.

  • PDF

Temperature Dependent Mdbility Characteristics of InSb Thin Film (홀센서 InSb 박막 이동도의 온도의존성)

  • 이우선;조준호;최권우;김남오;김형곤;김상용;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.582-585
    • /
    • 2001
  • InSb temperature dependent hall effect of multilayerd structures were investigated. According to variation of magnetic field measured hall coefficient, Hall mobility, carrier density and hall voltage. For the measurement of electrical properties of hall device, evaperated InSb thin film fabricated with series and parallel multilayers. We found that the XRD analysis of InSb thin film showed good properties at 200$^{\circ}C$, 60 minutes. Resistance of ohmic contact increased linearly due to increasing current. Some of device fabrication technique and analysis of Hall effect were discussed.

  • PDF

Temperature Dependent Hall Effect Characteristics of InSb Thin Film (InSb 박막 홀효과의 온도의존성)

  • 이우선;조준호;최권우;김남오;김상용
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.21-24
    • /
    • 2000
  • lnSb temperature dependent hall effect of multilayerd structures were investigated. According to variation of magnetic field measured hall coefficient, Hall mobility, carrier density and hall voltage. For the measurement of electrical properties of hall device, evaperated InSb thin film fabricated with series and parallel multilayers. We found that the XRD analysis of InSb thin film showed good properties at 20$0^{\circ}C$, 60 minutes. Resistance of ohmic contact increased linearly due to increasing current. Some of device fabrication technique and analysis of Hall effect were discussed.

  • PDF

Complex Modal Testing of Asymmetric Rotors Using Magnetic Exciter Equipped with Hall Sensors

  • Lee, Chong-Won;Kim, Si-Kyoung
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.866-875
    • /
    • 2001
  • The complex modal testing methods developed for asymmetric rotors are briefly discussed and their performances are experimentally evaluated. For the experiments, a laboratory test rotor is excited by using a newly developed, cost effective magnetic exciter equipped with Hall sensors, which measure the excitation forces. It is concluded that the exciter system is characterized by a wide bandwidth and a high resolution for both the excitation and force measurement, and that the one-exciter/two-sensor technique for complex modal testing of asymmetric rotors is superior to the standard two-exciter/two-sensor technique in terms of practicality and realization.

  • PDF