• Title/Summary/Keyword: Half-cell method

Search Result 160, Processing Time 0.029 seconds

A Study on the Application of FRP Hybrid Bar to Prevent Corrosion of Reinforcing Bar in Concrete Structure (콘크리트구조물 중의 철근 부식 저감을 위한 FRP Hybrid Bar의 적용성 연구)

  • Lee, Seung-Tae;Park, Kwang-Pil;Park, Ki-Tae;You, Young-Jun;Seo, Dong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.559-568
    • /
    • 2019
  • Recently, the infrastructure of the marine environment has been increasing. Therefore, there has been increasing interest in increasing the durability of structures. The FRP Hybrid Bar with improved durability against corrosion was developed in recent years. On the other hand, studies that evaluate the corrosion resistance are insufficient. In this study, the corrosion resistance according to the type of rebar in concrete was assessed and analyzed. The experiment used steel bars and FRP Hybrid Bar. The corrosion test method was a galvanic current and half-cell potential method. The accelerated corrosion test was carried out by four levels (0%, 1.5%, 3%, and 6%) of chloride added to the concrete. The galvanic current measurements revealed no corrosion current in the FRP Hybrid Bar. The half-cell measurement also showed the corrosion resistance of the FRP Hybrid Bar. Therefore. FHB can be used as an alternative steel for structures where a marine environment and steel corrosion are predicted.

Solution of higher order mode cutoff frequencies in TEM cells by Galerkin method (Galerkin 법을 적용한 TEM cell들의 고조 모드 차단 주파수 해석)

  • 윤재훈;이혁재;김정기
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10B
    • /
    • pp.1885-1894
    • /
    • 1999
  • The higher mode cutoff frequencies in Crawford TEM cells computed by the Galerkin method(GM) describe in this paper. The authors also report the half mode boundaries to solve not only the cut-off frequencies of symmetric TEM cells and those of asymmetric TEM cells. It is shown that the measured resonant frequencies of the present symmetric TEM cells and a designed asymmetric TEM cell are agreed with the calculated results.

  • PDF

Performance of Pt/$WO_3$ and Pt-$WO_3$/C electrode systems for direct methanol fuel cell (직접메탄올 연료전지용 백금/삼산화텅스텐 및 백금-삼산화텅스턴/탄소 전극계의 성능 평가)

  • Lee, C.H.;Lee, C.W.;Jung, D.W.;Shin, D.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1358-1360
    • /
    • 1997
  • In this paper, the performance of Pt/$WO_3$ and Pt-$WO_3$ electrodes was studied for the direct methanol fuel cell. The characteristics of Pt/$WO_3$ electrode which was prepared by using electrodeposition method was tested with half-cell experiment. The characteristics of Pt-$WO_3$/C electrode which was Prepared by using freeze-drying method was tested with a single cell experiment. The performance of DMFC single cell which was prepared by Pt-$WO_3/C$ and Pt/C showed a current density of $32mA/cm^2$ at $110^{\circ}C$ & 0.3V(0.5mg Pt/$cm^2$).

  • PDF

An Experimental Study on the Reinforcement Corrosion in Concrete Using Granulated Blast Furnace Slag (고로슬래그 미분말을 사용한 콘크리트 내의 철근부식에 관한 실험적 연구)

  • 이동혁;김은겸;김영웅;김영철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.761-766
    • /
    • 2002
  • This paper was peformed to verify the effect that granulated blast furnace slag gets in reinforcement corrosion resistance about chloride ion that invade from outside. An experiment accelerated for the reinforcement corrosion through repeat of brine digestion and dry. Reinforcement corrosion investigated half cell potential method of measurement by ASTM C876 and corrosion area ratio. If granulated blast furnace slag metathesis ratio is high generally that looked the corrosion of reinforcement decreasing as a result that evaluate reinforcement corrosion by ASTM C876 canon in this research. It showed high resistance about reinforcement corrosion that use normal portland cement and increase the metathesis rate of granulated blast furnace slag, as a result that evaluate metathesis rate effect of granulated blast furnace slag according to cement kind. when the test piece split destroying, area rate of reinforcement corrosion showed about result of half cell potential measurement.

  • PDF

Analysis on IBEM for consideration on reinforced concrete slab resistance

  • Kyung, Je-Woon;Tae, Sung-Ho;Lee, Han-Seung;Lee, Sung-Bok
    • Computers and Concrete
    • /
    • v.5 no.6
    • /
    • pp.545-558
    • /
    • 2008
  • The corrosion of RC structures demonstrates very complicated forms of deterioration intermingled together but all pointing to a decrease in the durability of RC structures due to the corrosion of reinforcing bars. Until now, nondestructive techniques, such as half-cell potential and polarization resistance, have been widely available in the world. The former provides information on the probability of corrosion while the latter is associated with information concerning corrosion rates. Inversion by the boundary element method (IBEM) was developed for considering concrete resistivity. The applicability of the procedure was examined through a numerical analysis and electrolytic tests for RC slabs. A distribution in such concrete resistivity is relatively inhomogeneous including cracks on the surface of slabs. Regarding cracks in concrete, the relative coefficient of concrete resistance was introduced to perform its analysis. Further, the procedure will be developed to identify the corroded region visually using 3-D VRML.

A Quantitative Evaluation on Steel Corrosion by Polarization Resistance Method (분극저항법에 의한 철근부식의 정량적 평가)

  • 정우용;손영무;윤영수;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.688-693
    • /
    • 2000
  • Recently great efforts and investment have been made in order to evaluate concrete durability by steel corrosion. But most of study is relatively or qualitatively estimated, therefore it has a great limitation in evaluating a remaining service life of concrete. In this research, steel corrosion rate was measured quantitatively by polarization resistance method and multi-regressed considering chloride, carbonation, coverage depth, relative humidity, W/C, and the use of deicing salts. And a half cell potential method was used at th same time for the purpose of comparing with polarization resistance method.

  • PDF

A New Asymmetrical PWM Bidirectional Half Bridge Converter for Wide Input Voltage Range Applications (넓은 입력 전압 범위를 갖는 새로운 비대칭 PWM 방식의 양방향 하프브리지 컨버터)

  • Kim, Jeong-Geun;Choi, Se-Wan;Park, Rae-Kwan;Chang, Seo-Geon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.235-242
    • /
    • 2009
  • In this paper a new asymmetrical PWM bidirectional half bridge converter is proposed. The proposed converter has simple structure and wide duty cycle range, and therefore is suitable for applications such as fuel cells which have wide voltage variation. With the proposed asymmetrical PWM method the current rating of switch and transformer is significantly reduced compared to the conventional phase angle control method, and ZVZCS and synchronous rectification can also be achieved. This could result in high efficiency and high power density. The proposed converter is analytically compared to the conventional converter, and the proposed method was validated through the experiment.

A Study on Sol-gel Preparation of Pt-Ru/C Anode Catalysts for Direct Methanol Fuel Cells (솔-젤 합성에 의한 직접 메탄올 연료전지용 고분산 Pt-Ru/C 음극 촉매의 제조)

  • Lee, Kang-Hee;Kim, Il-Gon;Park, Tae-Jin;Suh, Dong-Jin
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.13-17
    • /
    • 2003
  • Cryogel and aerogel Pt-Ru/C were synthesized by the sol-gel process for the electrooxidation of methanol. From XRD analysis, it was found that the catalysts had highly dispersed Pt-Ru alloys on carbon support although high temperature treatments have been conducted. Electrocatalytic activities of 3 type aerogel catalysts were investigated in half cell experiments by cyclic voltammetry. Among them, Phloroglucinol-Formaldehyde(PF) type catalyst shows the highest activity. From the results of deactivation test for each catalysts, the aerogel catalysts are found to have excellent durability compared with those prepared by colloidal method.

Nulling algorithm design using approximated gradient method (근사화된 Gradient 방법을 사용한 널링 알고리즘 설계)

  • Shin, Chang Eui;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.1
    • /
    • pp.95-102
    • /
    • 2013
  • This paper covers nulling algorithm. In this algorithm, we assume that nulling points are already known. In general, nulling algorithm using matrix equation was utilized. But, this algorithm is pointed out that computational complexity is disadvantage. So, we choose gradient method to reduce the computational complexity. In order to further reduce the computational complexity, we propose approximate gradient method using characteristic of trigonometric functions. The proposed method has same performance compared with conventional method while having half the amount of computation when the number of antenna and nulling point are 20 and 1, respectively. In addition, we could virtually eliminate the trigonometric functions arithmetic. Trigonometric functions arithmetic cause a big problem in actual implementation like FPGA processor(Field Programmable gate array). By utilizing the above algorithm in a multi-cell environment, beamforming gain can be obtained and interference can be reduced at same time. By the above results, the algorithm can show excellent performance in the cell boundary.

The Dual Design of Fuel Cell Hybrid Power System using Dual Converter PCS (1.5kW 연료전지 복합발전 시스템의 듀얼 컨버터 설계)

  • Shin, Soo-Cheol;Lee, Hee-Jun;Hong, Suk-Jin;Kim, Hak-Sung;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.67-75
    • /
    • 2013
  • In this paper, parallel input/serial output dual converter is designed appropriately for fuel cell hybrid power system. In case of proposed converter, zero voltage switching condition is designed without additional resonance device using leakage inductance of transformer and output capacitance of switch, and zero voltage switching method is used. Also, the system method is for increasing power by connecting half-bridge in parallel and increasing output voltage by connecting secondary output of transformer in serial. Through this method we can increase power and decrease volume of system. So in this paper, dual converter is designed. 1.5kW fuel cell hybrid power system was implemented, and system operation and stability was verified through experiment.