• Title/Summary/Keyword: Half bridge control

Search Result 221, Processing Time 0.03 seconds

Off-time Control Method for High Power Density AC/DC Adapter (고전력밀도 AC/DC Adapter를 위한 off-time 제어법)

  • Kang, Shin-Ho;Jang, Jun-Ho;Hong, Sung-Soo;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.510-516
    • /
    • 2007
  • The proposed method offers an improved control method for high power density AC/DC adapter by using more energy efficient electrical equipments. Power factor correction (PFC) topology is based on boost topology with boundary conduction mode (BCM). DC/DC topology is based on half-bridge topology with fixed 50% duty and newly introduced off-time control method, which helps to reduce size of the semiconductor and the magnetic devices. Test results with 85W AC/DC adapter (18.5V/4.6A) design show that the measured efficiency is 90% with power density of $36W/in^3$. It also shows low no load power consumption of about 0.5W.

A Study on the Power Control Characteristics of a Power Supply for Electrodeless Lamp (무전극 램프(Electrodeless Lamp) 구동용 전원장치의 전력제어 특성에 관한 연구)

  • Lee, Sung-Geun;Jeon, Su-Kyun;Jang, Min-Kyu;Kim, Dong-Sok;Kim, Yoon-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.65-67
    • /
    • 2003
  • This paper describes a design of power supply for electrodeless lamp system to be easy to control electric power widely keeping the high power factor. Proposed system is composed of power factor correction(PFC) circuit, half bridge(HB) inverter, high voltage transformer, full wave rectifier to supply dc number kV's magnetron(MGT) anode voltage in the second of high voltage transformer and magnetron. It was confirmed that the proposed circuits can correct the 99.8[%] power factor and control input power of the magnetron up to 33.3[%] linearly by adjusting of pulse frequency of the inverter through the experiment.

  • PDF

A Study on the Remote Monitoring and Control of Ship's Emergency Lighting System (선박 비상조명 원격 모니터링 제어)

  • Yang, Hyun-Suk;Kim, Kun-Woo;Lim, Hyun-Jung;Moon, Jung-Pil;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.207-210
    • /
    • 2005
  • This paper describes a design of several ship's emergency lighting system(SELS) that power factor is improved and power is controlled extensively, and techniques to control and monitor this system in remote distance by PC serial communication. The remote monitoring control system is composed of emergency power supply system (EPSS), half bridge(HB)inverter, fluorescent lamp(FL), microprocessor, multi communication interface. EPSS checks the voltage of the emergency backup battery in real time. In case that the voltage of 13[V] or less has been detected for 5[msec] or longer for 3 times in a row, charger circuit is connected for battery charging. Experimental works using proposed system confirm that speedy and stable power to be supplied when main power source cut-off, compared with conventional analog type, and input power up to 35.0[%] by adjusting of pulse frequency of the HB inverter.

  • PDF

Design and Control Strategy for Autonomous and Seamless Mode Transition of High Efficiency Bidirectional DC-DC Converter for ISG Systems (ISG 시스템용 고효율 양방향 DC-DC 컨버터의 설계 및 자율적이며 끊김없는 모드전환을 위한 제어전략)

  • Park, Jun-Sung;Kwon, Min-Ho;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.19-26
    • /
    • 2016
  • In this study, a bidirectional DC-DC converter for idle stop and go (ISG) is developed to reduce fuel consumption. A three-phase non-isolated half-bridge converter is selected through a design method by considering efficiency and volume. According to the state of charge of the batteries at both the low-voltage and high-voltage sides, buck mode, which charges a low-voltage battery from the generated motor energy, and boost mode, which provides power to the motor from the low- and high-voltage battery sides, are required in the ISG system. Hence, an autonomous and seamless bidirectional control method using a variable current limiter is proposed for mode change. A 1.8 kW engineering sample of the proposed converter has been built and tested to verify the validity of the proposed concept. The maximum efficiencies, including gate driver and control circuit losses, are 96.4% in charging mode and 96.1% in discharging mode.

Thyristor전력변환기-전동기계의 무효전력의 처리에 관한 연구

  • 유철로
    • 전기의세계
    • /
    • v.31 no.1
    • /
    • pp.50-58
    • /
    • 1982
  • As a method for improving the power factor and the waveform of ac line current drawn by ac to dc converters, converters of pulse-width control type with forced commutation circuits have been developed in recent years. However, these converters have rather complex commutation circuits which contain auxiliary thyristors in addition to the main thyristors, and their performance is not satisfactory. This paper proposes a new pulse-width controlled ac to dc converter, and analyses its commutation mechanism and its input and output characteristics. The proposed converter circuit consists of a usual thyristor bridge circuit with series diodes to which reactors and diodes are added. This circuit dose not contain auxiliary thyristors, and in this sense it is simpler than the previous converter circuits of pulse-width control type. Since the main thyristors of the converter can be forcedly turned off several times in a half cycle of source voltage, a pulse-width modulation control is possible in order to improve the current waveform as well as the power factor on ac line side. As to dc output side it is shown that the adjustable range of output voltage is wide and the voltage regulation is good due to a rapid reversal of voltage across the commutating capacitors by LC resonance during commutation period. It is also shown that the regenerative operation of the converter is possible.

  • PDF

A novel controller for switching audio power amplifier with digital input (디지털 PWM 입력 D급 음향 증폭기를 위한 새로운 제어기법)

  • Park, Jong-Hu;Kim, C.G.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.976-979
    • /
    • 2002
  • A new controller for switching audio power amplifier with digital PWM input is proposed- Bi-directional Saw-tooth Error Correction (BSEC). This control method for high quality switching amplifier is based on a pulsed edge correction approach using PWM audio signal input as a reference of power switching digital to analog converter. The proposed controller has excellent features such as wide error correction range and no limitation on the modulation index. The controller is implemented in the half-bridge class D amplifier and the performance is verified through hardware experiments. It delivers 100W into 4${\Omega}$ load with less than 0.2% of total harmonic distortion (THD) all over operating range and an maximum efficiency of 82%.

  • PDF

Modified Electronic Ballasts to Prevent the Signal Interference

  • Lee, Sang-Jin;Yoon, Dal-Hwan;Min, Seung-Gi;Kim, Kyung-Man
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1871-1875
    • /
    • 2003
  • The cancellation of the output signal occur between output tubs have occurred place an electromagnetic interference and deteriorated the light efficiency of the neon tub. In order to prevent this problems, we have developed the modified electronic ballast for neon(MEBN). The MEBN have used a shielded line to the output and designated partly the half-bridge in the middle of the circuit. In an experimental results, this will be lengthen the life of the neon tub and obtain the effect which shields an electromagnetic wave to injurious to the people’s body.

  • PDF

Voltage Control of Single-Phase Half Bridge Inverter Using a Repetitive Controller (반복 제어기를 이용한 단상 하프 브리지 인버터의 전압제어)

  • Park, Jonghwa;Jo, Hyeungil;Jo, Hyunsik;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.381-382
    • /
    • 2016
  • 본 논문에서는 비례 공진 제어기와 반복 제어기를 결합한 단상 하프 브리지 인버터의 전압 제어에 대해 연구하였다. 연구결과 고조파 발생 시 전체적으로 시스템에 문제를 야기하는 것을 확인하였으며, 이러한 문제를 해결하기 위해 기본파 성분을 제어하던 기존의 비례 공진 제어기에 반복 제어기 알고리즘을 결합하였다. 그 결과 추가적으로 인버터 데드타임에 의해 발생하는 고조파를 보상하였다. 그에 따른 성능은 시뮬레이션을 통하여 비례 공진 제어기만을 사용했을 때와 비교, 분석 및 검증하여 THD가 7.91[%]에서 4.62[%]로 약 3.29[%] 감소하는 것을 확인하였다.

  • PDF

A Dimmable High Frequency Resonant Inverter for Electrodeless Lamps (조광제어형 무전극 램프용 고주파 공전형인버터)

  • Yeon, Jae-Eul;Cho, Kyu-Min;Oh, Won-Seok;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.487-489
    • /
    • 2004
  • As the electrodes are not needed, the electrodeless lamps using the induction discharge have a long lifetime and are robust against the variable output condition of a ballast. This paper proposed a dimmable resonant inverter for the electrodeless lamps. The proposed resonant inverter formed a half bridge inverter adopted FWM to control the average output power of the inverter and the illumination of a lamp. In this paper, the proposed dimming algorithm was described and the prototype experimental setup for 100W electrodeless lamps was carried out to verify the validity of the proposed dimming method.

  • PDF

Implementation of a High-Power-Factor Single-Stage Electronic Bal last for fluorescent lamps (전단일전력단을 갖는 고역율 형광등용 전자식 안정기 구현)

  • 서철식;박재욱;김해준;노채균;김동희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.123-127
    • /
    • 2001
  • In this paper, prototype high-power-factor single-stage electronic ballast for fluorescent lamps is designed and implemented. A new low cost single stage high power factor electronic ballast for fluorescent lamps is based on integration of two-boost converter and LC type high frequency resonant converter. A ballast is obtained by simple construction, because full bridge rectifier diode is eliminated and simple control circuit is applied. Using two boost converter operating positive and negative half cycle respectively at line frequency (60Hz), operation in discontinuous conduction mode performs high power factor. The experimental results Show the good performance as PF 0.99, $A_{THD}$ 15.4%, and CF 1.65 at Output 63.5W.W.

  • PDF