• Title/Summary/Keyword: Ha-So

Search Result 3,552, Processing Time 0.03 seconds

Biodegradable implants for orbital wall fracture reconstruction

  • Jang, Hyeon Uk;Kim, So Young
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.2
    • /
    • pp.99-105
    • /
    • 2020
  • Background: Due to the different handling properties of unsintered hydroxyapatite particles/poly-L-lactic acid (uHA/PLLA) and polycaprolactone (PCL), we compared the surgical outcomes and the postoperative implantation accuracy between uHA/PLLA and PCL meshes in orbital fracture repair. Methods: Patients undergoing orbital wall reconstruction with PCL and uHA/PLLA mesh, between 2017 and 2019, were investigated retrospectively. The anatomical accuracy of the implant in bony defect replacement and the functional outcomes such as diplopia, ocular motility, and enophthalmos were evaluated. Results: No restriction of eye movement was reported in any patient (n= 30 for each group), 6 months postoperatively. In the PCL group, no patient showed diplopia or enophthalmos, while the uHA/PLLA group showed two patients with diplopia and one with enophthalmos. Excellent anatomical accuracy of implants was observed in 27 and 22 patients of the PCL and uHA/PLLA groups, respectively. However, this study showed that there were neither any significant differences in the surgical outcomes like diplopia and enophthalmos nor any complications with the two well-known implants. Conclusion: PCL implants and uHA/PLLA implants are safe and have similar levels of complications and surgical outcomes in orbital wall reconstruction.

HISTOLOGIC EvALUATION OF BONE HEALING AROUND TITANIUM PLASMA SPRAYED AND HYDROXYAPATITE-COATED IMPLANTS IN DOGS (성경 대퇴골에 매식된 Titanium Plasma Spray 및 Hydroxyapatite 피복임프란트 주위의 골치유 양상)

  • Huh, Ki-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.418-437
    • /
    • 1995
  • The effect of the hydroxyapatite coatings on Titanium implants has been the subject of recent investigations. So far, the use of HA coating remains substantially controversial.This study was aimed to evaluate histologically the bone healing patterns around titanium plasm sprayed(TPS) amd HA-coated implant after implantation into the femur neck of ten adult dogs. After implantation, animals were sacrificed at the intervals of 2,4,6,8 and 12 weeks.The fluorescent dyes were injected on the postoperative 4th and 12th week into the animals supposed to be killed at the 12th week. The morphology and direction of new bone formation was similar in both TPS and HA-coated implants.There was a tendency toward more bone formation in the cortical bone area than in the cancellous bone area. Histologically,in the interface of the HA-coated implants, bone response and bone maturation was faster, compared to the TPS implants in the 2nd and 4th week. By fluorescent microscopy, new bone formation was active in the 4th week around both implants and was directed from the periosteum overlying cortical bone to the cancellous bone. These results suggest that the bone formation and maturation is faster during the early healing stage in the interface of the HA-coated implant and where the cortical bone quality is poor, HA coated implant is superior to the TPS implant in the early phase of new bone formation.

  • PDF

A Study on the Inundation Analysis of the Nam River Lowland Using GIS and FLUMAN (GIS와 FLUMAN을 이용한 남강 저지대 침수분석에 관한 연구)

  • Choi, Hyun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.2
    • /
    • pp.49-56
    • /
    • 2017
  • In this study, flood analysis was conducted to prepare for damage caused by typhoons and heavy rain due to abnormal climate and climate change. Two - dimensional flooding analysis using the FLUMEN model, which is widely used for national and international flood risk mapping, was conducted for the Nam River Basin, which is the tributary of the Nakdong River. This study divides the topography into $5m{\times}5m$ DEM by ArcView, so that the accuracy of river repair and hydrological characterization and flood area identification can be maximized. As a result of simulation of water flooding, 163.3ha in section 1, 227.7ha in section 2 and 59.9ha in section 3 were simulated.

Chemical Properties and Nutrient Loadings of Rainwater during Farming Season (영농기 강우의 화학적 특성 및 부하량 평가)

  • Ko, Byong-Gu;Kim, Min-Kyeong;Lee, Jong-Sik;Kim, Gun-Yeob;Park, Seong-Jin;Kwon, Soon-Ik;Jung, Goo-Buk;Lee, Deog-Bae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.5
    • /
    • pp.578-583
    • /
    • 2010
  • Acid rain and its problem to environment such as acid precipitation and environmental problems related to the air pollution in East Asia has been emerging. To evaluate the acidity and chemical characteristics of rainwater precipitated in western Korea, Suwon and Taean, its pH and ion concentrations were investigated during farming season (April to November) in 2009. Also, ion composition and cation-affected neutralization were determined to evaluate the contribution of cations on the acidity of rainwater. Ion and electrical conductivity between the measured and the estimated showed high correlation. The $Na^+$ in rainwater was the main cation followed by ${NH_4}^+>Ca^{2+}>H^+>Mg^{2+}>K^+$. Sum of $Na^+$ and ${NH_4}^+$ contents was over 65% of total cations contents. In the case of anions, the concentration was in order of ${SO_4}^{2-}>{NO_3}^->Cl^-$. The ${SO_4}^{2-}$ among anions in rainwater composed about 61%, which showed on average 130.2 ${\mu}eq\;L^{-1}$ and 121.3 ${\mu}eq\;L^{-1}$ during monitoring at Suwon and Taean, respectively. Also, 89.6 and 88.6% of soluble sulfate in rainwater at Suwon and Taean area was NSS-${SO_4}^{2-}$ (Non-Sea Salt sulfate). Especially, ${NH_4}^+$ and $Ca^{2+}$ contributed greatly in neutralizing the acid rain in dry season. Total nitrogen content flowed into soil from rain was around 1~2 kg $ha^{-1}$ in each month, but in July at Suwon, it reached 6 kg $ha^{-1}$ due to heavy rain (over 7.3 mm).

Residual Effects of Coal Fly Ashes on the Growth of Rice Crop Subsequent to Malting Barley (맥주보리 후작(後作) 벼의 생육(生育)에 대한 석탄회(石炭灰) 시용잔효(施用殘效))

  • Ha, Ho-Sung;Kang, Ui-Gum
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.4
    • /
    • pp.373-379
    • /
    • 1998
  • Fly ash application with a rate 0, 50, 100, $150Mg\;ha^{-1}$ in clay loam paddy, which had properties of pH 5.3 and low contents of silicate, gave a positively residual effects on the growth of rice crop subsequent to malting barley. The responses of rice yields to fly ash application were in the order of bituminous coal fly ash(BCFA) 100 > 150 > 50 > anthracite fly ash(AFA) 50 > 100 > none > AFA $150Mg\;ha^{-1}$. As a result, yields responses of milled rice were ranged from $6.2(50Mg\;ha^{-1}){\sim}14.4%(100Mg\;ha^{-1})$ by BCFA and from $-0.6(150Mg\;ha^{-1}){\sim}6.6%(50Mg\;ha^{-1})$ by AFA showing maximum yields of 5.084 and $4.738Mg\;ha^{-1}$ by the former and the latter, respectively. Rice plant showed lodging indices ranging from $20(50Mg\;ha^{-1}){\sim}40%(150Mg\;ha^{-1})$ by BCFA and from $1.3(150Mg\;ha^{-1}){\sim}15%(50Mg\;ha^{-1})$ by AFA at harvesting stage. In especial, soils applicated with BCFA contained a good fertility in terms of pH, available $P_2O_5$ and $SiO_2$, and exchangeable Ca and Mg etc. so that possibly harbored 3yr-residual effects of the fly ash on crop subsequent to this rice.

  • PDF

development of small size corrosion monitoring system for under ground metal structures (지중 금속구조물 부식감시를 위한 측정단자함 인입형 소형 계측 장치개발에 관한 연구(II))

  • Lee, Jae-Duck;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Gu;Ha, Yun-Chul;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.104-106
    • /
    • 2004
  • There are many under grounds facilities like oil pipes, gas pipes, water pipes, oil tanks, etc. and severe corrosion of these facilities made big problems. Fire, wide area water and soil pollution, massive and hazardous explosion, etc. can make big problems and cause big economical loss. So, various technologies were developed to keep these undergrouns facilities safely, and cathodic protection is one of it. For cathodic protection, one must detect potential of pipes, and there are so many test box to check pipes potentials. In this thesis, we describe on the development of small size corrosion monitoring system that measure pipes potentials easily and economically.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

Detection of Surges by Frequency Analysis on Lan Equipment (랜설비에 유기되는 이상전압의 주파수분석을 통한 서지의 검출)

  • Huh, Chang-Su;Lee, Se-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.213-215
    • /
    • 2001
  • We investigated the frequency characteristics of surges induced on Lan equipments by using V-F converter. which installed on the second part of protection system. We stored and analyzed the frequency converting data with the amplitude of overvoltage. In addition. The data acquisition system was made so that we could be examine the results wave through WEB. From this results, it is found that this frequency analysis could be helped for design and protection of various undesired surges.

  • PDF

A Calculation Method for Temperature Distribution of Hot Water Pipe under Unsteady Condition (비정상조건하의 온수배관의 온도분포에 관한 수치계산법 연구)

  • Choi, C.H.;Suh, S.J.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.13-21
    • /
    • 1999
  • Calculation method about the water temperature variable inside hot water pipe had proposed in the past does not correspond with branch pipe system, variable of water volume, variable of entrance water temperature, using and so on. A calculation method proposed in this paper can solve above problems, and calculate the kinds variation of the water temperature inside pipe in the real use state of the hot water pipe.

  • PDF