• Title/Summary/Keyword: Ha partial pressure

Search Result 63, Processing Time 0.028 seconds

Characteristics and Nursing Activities of Severe Trauma Patients Regarding the Main Damaged Body Parts (중증외상환자의 주 손상 부위별 특성과 간호활동)

  • Kim, Myung Hee;Kim, Myung Hee;Park, Jung Ha
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.4
    • /
    • pp.210-218
    • /
    • 2013
  • Purpose: The purpose of this study was to identify the characteristics and nursing activities of severe trauma patients regarding damaged body parts in Busan Regional Emergency Medical Center. Methods: A survey using a 'trauma patient information questionnaire and a list of nurse activities' was conducted with 133 patients over 15 points ISS on EMR from June 1, 2011 to May 31, 2012. The collected data were analyzed by the SPSS/WIN 12.0 program. Results: Almost all of the subjects were men, and the mean age was 48.8. The amount of road traffic accidents was 60.4%, and the mean RTS and ISS were 6.08, and 23.14 points. Nursing activities in common were airway management, assessment of LOC & GCS, and EKG monitoring. Most of head and neck trauma patients were cared for manasing using intracranial pressure: each patience had the following assessed: pupil size and light reflex, they were checked the leak of CSF, kept $30^{\circ}$ head elevation, and administered medications. Some of chest trauma patients were treated for chest tube and central venous catheter insertion. Partial abdominal trauma patients were administered analgesic and cared for using arterial pressure measurement. Part of the limbs and pelvis trauma patients were given a blood transfusion. Conclusion: Based on the results, the characteristics and nursing activities were specific according to the specific damaged body parts.

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Correlation between Qi-Stagnation and Pressure Pain Threshold on $CV_{17}$ (Danzhong : 膻中) in Burning Mouth Syndrome Patients - In the Perspective of Quantification of Pressure Pain Threshold on $CV_{17}$ by using Algometer - (구강작열감증후군 환자에서 기울과 전중($CV_{17}$)압통의 상관성 - Algometer를 이용한 전중압통의 정량화 측면에서 -)

  • Kang, Kyung;Kim, Jin-Sung;Seon, Jong-Ki;Son, Ji-Hee;Kim, Ju-Yeon;Jang, Seung-Won;Son, Ji-Young;Lee, Hyun-Ju;Ryu, Bong-Ha
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.4
    • /
    • pp.498-510
    • /
    • 2012
  • Objectives : This study was designed to find out whether there is a correlation between qi-stagnation score and pressure pain threshold (PPT) on acupuncture point $CV_{17}$ in burning mouth syndrome (BMS) patients. Methods : Thirty BMS patients who newly visited Oral Disease Clinic at the Kyung Hee University Korean Medicine Hospital were surveyed. The subjects were evaluated on age, illness duration, sex, self-assessed severity of BMS, qi-stagnation score, and PPT on 3 acupuncture points ($CV_{17}$, Rt. $SP_9$, Lt. $SP_9$). Results : There was significant correlation between age and PPT on $CV_{17}$ (p=0.005). Therefore, partial correlation analysis with age as control variable was done, and the result showed significant correlation between qi-stagnation score and PPT on $CV_{17}$ (p=0.001). Qi-stagnation diagnostic point by PPT on $CV_{17}$ was suggested as 3.8056 $kg/cm^2$ based on the fact that diagnostic score is 28.50 in the qi-stagnation questionnaire. Furthermore, considering that PPT is effected by age, we could attain qi-stagnation diagnostic equation of PPT on $CV_{17}$, that is suggested as $0.047{\times}(age)+0.848kg/cm^2$. PPT of 3 acupuncture points ($CV_{17}$, Rt. $SP_9$, Lt. $SP_9$) was compared, and the result showed that PPT was significantly lower on $CV_{17}$ (w/Rt $SP_9$: p=0.022, w/Lt. $SP_9$: p=0.012). Also, significance and correlation coefficient with qi-stagnation were higher on $CV_{17}$ (p<0.001, r=-0.620) than Rt. $SP_9$ (p=0.023, r=-0.413) or Lt. $SP_9$ (p=0.014, r=-0.444). Conclusions : The result of this study suggested that PPT on $CV_{17}$, measured quantitatively by algometer, had a strong correlation with qi-stagnation score in BMS patients. Therefore, the study showed that $CV_{17}$ can be a useful acupuncture point in diagnosing qi-stagnation by measuring PPT in BMS patients.

The Pressure Effect of the Association of 2,4,6,N-Tetramethyl Pyridinium Iodide in Ethanol-Water Mixture (에탄올-물 혼합용매내에서 2,4,6,N-Tetramethyl Pyridinium Iodide의 회합에 대한 압력효과)

  • Jung-Ui Hwang;Jong-Gi Jee;Young-Hwa Lee;Uei-Ha Woo
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.2
    • /
    • pp.79-85
    • /
    • 1984
  • The ionic association constant(K) of 2,4,6, N-tetramethyl pyridinium iodide (TeMPI) in 95 volume percentage ethanol-water mixture were determined by a modified UV and conductance method at $25^{\circ}C$ to $50^{\circ}C$ under 1 to 2,000 bars. The K values increase with increasing pressure and have maximum value at $40^{\circ}C$. The partial molar volume hange (${\Delta}V$) has relatively small negative value and the absolute values of ${\Delta}$ are minimum at $40^{\circ}C$. The ion size parameter(a) of TeMPI have maximum value at $40^{\circ}C$. {\Delta}H^{\circ}$ values are zero, positive and negative at 40^{\circ}C$, $25^{\circ}C$ and $50^{\circ}C$ respectively. Other thermodynamic parameters such as the changes of standard entropy ({\Delta}S^{\circ}$) and free energy {\Delta}G^{\circ}$ were evaluated. From these experimental results, we came to conclusion that TeMPI is stabilized by the elevation of pressure and that of temperature below $40^{\circ}C$ but weakly dimerized at $40^{\circ}C$ because of the intermolecular hydrophobic interaction of eight methyl groups of two molecules. And it thermally decomposed above $50^{\circ}C$.

  • PDF

Risk Factors Associated with Frequent Hospital Readmissions for Exacerbation of COPD

  • Kim, Mi-Hyun;Lee, Kwang-Ha;Kim, Ki-Uk;Park, Hye-Kyung;Jeon, Doo-Soo;Kim, Yun-Seong;Lee, Min-Ki;Park, Soon-Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.4
    • /
    • pp.243-249
    • /
    • 2010
  • Background: Chronic obstructive pulmonary disease (COPD) is one of the leading causes of disability and mortality worldwide. The aim of this study was to evaluate the risk factors associated with recurrent hospital admissions for exacerbation of COPD in Korea. Methods: A retrospective study of 77 consecutive patients hospitalized for exacerbation of COPD at Pusan National University Hospital during the time period January 2005 to May 2008 was performed. The information was collected from the hospitalization period: clinical information, spirometric measures, and laboratory variables. In addition, socioeconomic characteristics, co-morbidity, anxiety, and depression were reviewed. Frequent readmission was defined as 2 or more hospitalizations in the year following discharge. Results: During the 1-year period after discharge, 42 patients (54.6%) reported one hospital admission and 35 patients (45.4%) reported 2 or more hospital readmissions. Among the 35 frequent readmission patients, 4 had more than 10 readmissions. Univariate analysis showed that a body mass index (BMI) <$18.5kg/m^2$, duration >36 months, forced expiratory volume in 1 second ($FEV_1$) <50% predicted, arterial $CO_2$ partial pressure ($PaCO_2$) >40 mm Hg, and arterial oxygen saturation ($SaO_2$) <95% at discharge were associated significantly with frequent readmissions. The multivariate analysis revealed that BMI <$18.5kg/m^2$, $PaCO_2$ >40 mm Hg at discharge were independently associated with frequent readmissions for exacerbation of COPD. Conclusion: Frequent readmissions for exacerbation of COPD were associated with low BMI and hypercapnia at discharge.

Fabrication of Thick SmBCO/IBAD-MgO coated conductor (후막 SmBCO/IBAD-MgO 초전도 박막선재의 제조)

  • Lee, J.H.;Kang, D.K.;Ha, H.S.;Ko, R.K.;Oh, S.S.;Kim, H.K.;Yang, J.S.;Jung, S.W.;Moon, S.H.;Youm, D.;Kim, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.9-9
    • /
    • 2009
  • Coated conductor is required to have good critical current property for high efficiency of electric power applications. Until now, long coated conductor does not show high Jc over 3 MA/$cm^2$ in thick superconducting layer because of texture degradation by thick superconducting layer. In this study, in order to overcome this issue, thicker superconducting layer was deposited with optimized conditions to reduce the degradation of critical current density. SmBCO superconducting coated conductor was deposited with 1~3 um of thickness at $750\sim850^{\circ}C$ under 15~20 mTorr of oxygen partial pressure using batch type EDDC( evaporation using drum in dual chamber). The buffered substrate for superconducting layer deposition was used IBAD-MgO template with the architecture of $LaMnO_3/MgO/Y_2O_3/Al_2O_3$/Hastelloy. After fabrication of coated conductor, critical current was measured by 4-prove method under self-magnetic field and 77K. In addition, surface morphology and texture were analyzed by SEM and XRD, respectively. 3 um thick SmBCO coated conductor shows highest $I_C$ values of 638A/cm-w in 1 m long in the world.

  • PDF

Effect of Hydrophilic- and Hydrophobic-Media on the Fermentative Hydrogen Production in Trickling Bed Biofilter (생물학적 수소생산을 위한 Trickling Bed Biofilter에서의 친수성과 소수성 담체의 영향)

  • Jeon, Byung-Seung;Lee, Sun-Mi;Kim, Yong-Hwan;Chae, Hee-Jeong;Sang, Byoung-In
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.465-469
    • /
    • 2006
  • Two mesophilic trickling bed bioreactors filled with two different types of media, hydrophilic- and hydrophobic-cubes, were designed and tested for hydrogen production via anaerobic fermentation of sucrose. Each reactor consisted of a column packed with polymeric cubes and inoculated with heat-treated sludge obtained from anaerobic digestion tank. A defined medium containing sucrose was fed with changing flow rate into the capped reactor, hydraulic retention time and recycle rate. Hydrogen concentrations in gas-phase were constant, averaging 40% for all conditions tested. Hydrogen production rates increased up to $10.5 L{\cdot};h^{-1}{\cdot}L^{-1}$ of reactor when influent sucrose concentrations and recycle rates were varied. Hydrophobic media provided higher value of hydrogen production rate than hydrophilic media at the same operation conditions. No methane was detected when the reactor was under a normal operation. The major fermentation by-products in the liquid effluent of the both trickling biofilters were acetate and butyrate. The reactor filled with hydrophilic media became clogged with biomass and bio gas, requiring manual cleaning of the system, while no clogging occurred in the reactor with hydrophobic media. In order to make long-term operation of the reactor filled with hydrophilic media feasible, biofilm accumulation inside the media in the reactor with hydrophilic media and biogas produced from the reactor will need to be controlled through some process such as periodical backwashing or gas-purging. These tests using trickling bed biofilter with hydrophobic media demonstrate the feasibility of the process to produce hydrogen gas in a trickle-bed type of reactor. A likely application of this reactor technology could be hydrogen gas recovery from pre-treatment of high carbohydrate-containing wastewaters.

  • PDF

Mixed rare earth $(Nd_{1/3}Eu_{1/3}Gd_{1/3})Ba_2Cu_3O_{7-d}$ thin films by PLD (PLD법에 의한 혼합된 희토류계$(Nd_{1/3}Eu_{1/3}Gd_{1/3})Ba_2Cu_3O_{7-x}$ 고온 초전도 박막)

  • Ko, Rock-Kil;Bae, Sung-Hwan;Jung, Myung-Jin;Jang, Se-Hoon;Song, Kyu-Jeong;Park, Chan;Sohn, Myung-Hwan;Kang, Suk-Ill;Oh, Sang-Soo;Ha, Dong-Woo;Ha, Hong-Soo;Kim, Ho-Sup;Kim, Young-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.3-3
    • /
    • 2009
  • In order to investigate the possibility of using mixed rare earth $(Nd_{1/3}Eu_{1/3}Gd_{1/3})Ba_2Cu_3O_{7-x}$ (NEG123) as the superconducting layer of the HTS coated conductor, the NEG123 thin film was deposited epitaxialy on LAO(100) single crystal and IBAD_YSZ metal templates by pulsed laser deposition. Systematic studies were carried out to investigate the influences of deposition parameters of PLD on the micro structure, texture and superconducting properties of NEG-123 coated conductor. Deposition at oxygen partial pressure of 600 mTorr was needed to routinely obtain high quality NEG123 films with $J_c$'s (77K) over 2 MA/$cm^2$ and Tc's over 90K (${\Delta}T{\sim}2\;K$). We verified from magnetization study that the NEG123 has an improved in-field Jc as the field increases at temperatures between 10 K and 77 K compared with Gd123. The $J_c$ (77K, self field) and the value of onset $T_c$ of NEG123 thin film on LAO substrate was $4.0MA/cm^2$ and 92K, respectively. This is the first report, to the best of our knowledge, of coated conductors with NEG123 film as the superconducting layer which have Ic and Jc over 40 A/cm-width and 1.6 MA/$cm^2$ at 77K, self field. This study shows the possibility of using NEG123 film as the superconducting layer of the HTS coated conductor which can be used in high magnetic field power electric devices.

  • PDF

Rotordynamic Performance Measurements and Predictions of a FCEV Air Compressor Supported on Gas Foil Bearings (가스 포일 베어링으로 지지되는 연료전지 전기자동차용 공기압축기의 회전체동역학적 성능 측정 및 예측)

  • Hwang, Sung Ho;Moon, Chang Gook;Kim, Tae Ho;Lee, Jongsung;Cho, Kyung Seok;Ha, Kyoung-Ku;Lee, Chang Ha
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.44-51
    • /
    • 2019
  • The paper presents the rotordynamic performance measurements and model predictions of a fuel cell electric vehicle (FCEV) air compressor supported on gas foil bearings (GFBs). The rotor has an impeller on one end and a thrust runner on the other end. The front (impeller side) and rear (thrust side) gas foil journal bearings (GFJBs) are located between the impeller and thrust runner to support the radial loads, and a pair of gas foil thrust bearings are located on both sides of the thrust runner to support the axial loads. The test GFJBs have a partial arc shim foil installed between the top foil and bump strip layers to enhance hydrodynamic pressure generation. During the rotordynamic performance tests, two sets of orthogonally installed eddy-current displacement sensors measure the rotor radial motions at the rotor impeller and thrust ends. A series of speed-up and coast-down tests to 100k rpm demonstrates the dominant synchronous (1X) rotor responses to imbalance masses without noticeable subsynchronous motions, which indicates a rotordynamically stable rotor-GFB system. Finite element analysis of the rotor determines the rotor free-free (bending) natural modes and frequencies well beyond the maximum rotating frequency. The predicted damped natural frequencies and damping ratios of the rotor-GFB system reveal rotordynamic stability over the speeds of interest. The imbalance response predictions show that the predicted critical speeds and rotor amplitudes strongly agree with the test measurements, thus validating the developed rotordynamic model.

Hexagonal shape Si crystal grown by mixed-source HVPE method (혼합소스 HVPE 방법에 의해 성장된 육각형 Si 결정)

  • Lee, Gang Seok;Kim, Kyoung Hwa;Park, Jung Hyun;Kim, So Yoon;Lee, Ha Young;Ahn, Hyung Soo;Lee, Jae Hak;Chun, Young Tea;Yang, Min;Yi, Sam Nyung;Jeon, Injun;Cho, Chae Ryong;Kim, Suck-Whan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.3
    • /
    • pp.103-111
    • /
    • 2021
  • Hexagonal shape Si crystals were grown by the mixed-source hydride vapor phase epitaxy (HVPE) method of mixing solid materials such as Si, Al and Ga. In the newly designed atmospheric pressure mixed-source HVPE method, nuclei are formed by the interaction between GaCln, AlCln and SiCln gases at a high temperature of 1200℃. In addition, it is designed to generate a precursor gas with a high partial pressure due to the rapid reaction of Si and HCl gas. The properties of hexagonal Si crystals were investigated through scanning electron microscopy (FE-SEM), energy dispersive X-ray spectroscopy (EDS), high-resolution X-ray diffraction (HR-XRD), and Raman spectrum. From these results, it is expected to be applied as a new material in the Si industry.