• 제목/요약/키워드: HVDC cable

검색결과 61건 처리시간 0.02초

HVDC 시스템의 제어 게인에 대한 분석 및 정정 (The Analysis and Adjustment for the Control Parameter of HVDC System)

  • 김찬기
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.184-191
    • /
    • 2006
  • 본 논문은 HVDC 시스템의 고장분석과 제어게인 파라미터정정에 대한 내용을 다루고 있다. 본 논문에서 다루는 내용은 정류실패에 의한 과전압에 의해서 유발된 실제의 케이블 사고를 다룬다. 그리고 고장을 분석하기 위해서 샘플링 타임이 50us인 정밀 PSCAD/EMTDC Model을 이용하였으며, 최종적으로 분석결과에 의해 HVDC시스템의 제어 파라미터가 정정되었다.

Protection of the MMCs of HVDC Transmission Systems against DC Short-Circuit Faults

  • Nguyen, Thanh Hai;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.242-252
    • /
    • 2017
  • This paper deals with the blocking of DC-fault current during DC cable short-circuit conditions in HVDC (High-Voltage DC) transmission systems utilizing Modular Multilevel Converters (MMCs), where a new SubModule (SM) topology circuit for the MMC is proposed. In this SM circuit, an additional Insulated-Gate Bipolar Translator (IGBT) is required to be connected at the output terminal of a conventional SM with a half-bridge structure, hereafter referred to as HBSM, where the anti-parallel diodes of additional IGBTs are used to block current from the grid to the DC-link side. Compared with the existing MMCs based on full-bridge (FB) SMs, the hybrid topologies of HBSM and FBSM, and the clamp-double SMs, the proposed topology offers a lower cost and lower power loss while the fault current blocking capability in the DC short-circuit conditions is still provided. The effectiveness of the proposed topology has been validated by simulation results obtained from a 300-kV 300-MW HVDC transmission system and experimental results from a down-scaled HVDC system in the laboratory.

Development of Fault Location Algorithm and Its Verification Experiments for HVDC Submarine Cables

  • Jung, Chae-Kyun;Park, Hung-Sok;Kang, Ji-Won;Wang, Xinheng;Kim, Yong-Kab;Lee, Jong-Beom
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.859-868
    • /
    • 2012
  • A new fault location algorithm based on stationary wavelet transform and its verification experiment results are described for HVDC submarine cables in this paper. For wavelet based fault location algorithm, firstly, 4th level approximation coefficients decomposed by wavelet transform function are superimposed by correlation, then the distance to the fault point is calculated by time delay between the first incident signal and the second reflected signal. For the verification of this algorithm, the real experiments based on various fault conditions and return types of fault current are performed at HVDC submarine cable test yard located in KEPCO(Korea Electric Power Corporation) Power Testing Center of South Korea. It proves that the fault location method proposed in this paper is very simple but very quick and accurate for HVDC submarine cable fault location.

HVDC 해저케이블 접속재 신뢰성 평가를 위한 인정시험 (Reliability Test for the Repairing Joint in HVDC Sea Submarine Cable)

  • 양병모;박흥석;박준우;김종채;강지원;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.77-78
    • /
    • 2008
  • HVDC 케이블은 장거리 전력전송, 국가간 계통연계 비동기 전력계통연계, 전력의 시장화에 따른 전력공급 제어 필요에 따라 세계적으로 널리 사용되고 있다. 국내에서는 현재 유일하게 제주-해남간 HVDC 해저케이블이 운영 중에 있으며, 향후 제주도 안정적인 전력공급을 위하여 2011년에 제주-육지간 HVDC 해저케이블이 추가로 건설될 예정이다. 그래서 HVDC 해저 케이블의 안정적이고 신뢰성 있는 운영을 하기 위한 보수자재용 접속재 개발 및 신뢰성 평가가 필요하게 되었다. 본 논문에서는 제주-해남간 운영중인 HVDC 해저케이블 보수자재용으로 개발된 접속재에 대한 신뢰성 평가 방법으로 가장 많이 사용되고 있는 Electra 175, 189의 기계적 및 전기적 평가에 대하여 기술하고자 한다.

  • PDF

HVDC용 나노복합 절연재료의 DC절연파괴특성 연구

  • 정의환;윤재훈;이승수;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.155-155
    • /
    • 2009
  • This paper introduces the findings of a detailed study on breakdown voltage strength under DC voltage and the development of HVDC cable. Recently, Nano-fillers are attracting attentions of many researchers and engineers, since they seem to bring higher potentials for advancement of electrical insulating properties as nano-composites. Additives and fillers are often adopted to polymeric materials for improving insulating and machanical properties. We have improved the polymer composition and developed a new insulation material for HVDC cable. Each specimen blended at LDPE1 to antioxidant, LDPE2 to antioxidant, pure XLPE was manufactured respectively. The insulation performances of the proposed insulator were compared with specimens blended at nano powders. DC breakdown strength of LDPE1 specimen at 90[$^{\circ}C$] was higher than other specimens. The experimental results show that polar groups intorduced in moleculars chains of blended specimen plays an important role in enhancement of thermal conductivity.

  • PDF

육지-제주간 2차 HVDC SYSTEM 개요 (The Introduction of #2 HVDC SYSTEM)

  • 장석한;유승환;신명식;이규용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.107-109
    • /
    • 2008
  • Cheju-Haenam HVDC transmission system start it's commercial operation since 1998. JEJU island is supplied with it's about 45% of total electric power from main land with HVDC link. In JEJU island, the demand of electric power is growing every year. With a current power supply, electric power reserve rate will be below the recommended one. For a stable power supply to JEJU island, KEPCO start a construction of #2 HVDC transmission system. This report is for introduction and understanding of #2 HVDC system which will be installed between JEJU island and main land. This report includes a specification of converter station and DC cable. KEPCO expect that this system will solve the power supply problem and maximum wind power plant capacity problem as well.

  • PDF

제주계통의 안정적 운전에 대한 타당성 연구 (Feasibility Study for the Stable Operation of Cheju Network)

  • 김찬기;장재원;문봉수;심정운
    • 전력전자학회논문지
    • /
    • 제13권5호
    • /
    • pp.344-351
    • /
    • 2008
  • 본 논문의 배경은 제주지역의 안정적 전력공급을 위하여 최적의 전력공급체계를 분석한 논문이다. 본 논문에서 검토한 내용은 제주도 전력공급 현황파악 및 문제점 분석, 전력계통 운영측면에서 최적의 전력설비건설 타당성 검토 그리고 경제성 및 신뢰도 검토이다. 결론적으로 2011년에 HVDC 연계 선을 제주에 건설하는 경우에 경제성 평가(30년간 2011년 현가합 비교)를 한 경우 HVDC 연계선 추가건설이 기력(중유)발전이나 LNG 발전 보다 경제적임을 보여주고 있다. 그리고 신뢰도 측면에서도 좋은 역할을 할 것으로 기대되어진다.

국내 HVDC 해저케이블 도입 및 적용사례 소개 (The introduction of HVDC submarine cable application cases)

  • 유승환;홍승택;서승현;현기수;이동형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.394-396
    • /
    • 2008
  • 본 논문에서는 앞으로 전력시장 다변화 다각화 추세에 맞춰 현재 진행 중인 제주-육지간 2차 직류연계 사업뿐만 아니라 다양한 직류송전의 활용에 대비하여 HVDC 해저케이블에 대한 개념 정립 및 현재 운영중인 설비와 건설예정사업에 대한 소개를 통해 이해를 돕고자 한다.

  • PDF

바이폴 HVDC 시스템의 EMTP 시뮬레이션 (EMTP Simulation of Bipolar HVDC System)

  • 곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1053-1055
    • /
    • 1998
  • Using EMTP model which describes bipolar HVDC system, switching level simulation results are presented in this paper. Voltage synchronization at point of common coupling, gate pulse generation and current control loops are represented in TACS module. The system consists of 100 km submarine cable rated 300 MW and 12 pulse rectifier and inverter stations which are connected to equivalent three-phase sources and loads through the 154 kV AC lines, respectively. In convertor stations, harmonic filters and capacitor banks are equipped to cancel out the harmonics generated by converters and to supply the required reactive power.

  • PDF

A Decentralized Optimal Load Current Sharing Method for Power Line Loss Minimization in MT-HVDC Systems

  • Liu, Yiqi;Song, Wenlong;Li, Ningning;Bai, Linquan;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2315-2326
    • /
    • 2016
  • This paper discusses the elimination of DC voltage deviation and the enhancement of load current sharing accuracy in multi-terminal high voltage direct current (MT-HVDC) systems. In order to minimize the power line losses in different parallel network topologies and to insure the stable operation of systems, a decentralized control method based on a modified droop control is presented in this paper. Averaging the DC output voltage and averaging the output current of two neighboring converters are employed to reduce the congestion of the communication network in a control system, and the decentralized control method is implemented. By minimizing the power loss of the cable, the optimal load current sharing proportion is derived in order to achieve rational current sharing among different converters. The validity of the proposed method using a low bandwidth communication (LBC) network for different topologies is verified. The influence of the parameters of the power cable on the control system stability is analyzed in detail. Finally, transient response simulations and experiments are performed to demonstrate the feasibility of the proposed control strategy for a MT-HVDC system.