• Title/Summary/Keyword: HVAC

Search Result 605, Processing Time 0.03 seconds

A Numerical Study on Automobile Interior Environment (자동차 실내 환경에 관한 수치적 연구)

  • Lee, Kum-Bae;Jean, Hee-Ho;Ko, Seok-Bo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.325-330
    • /
    • 2006
  • Modern people spend more and more time in an automobile in their daily life. In this life, drivers and passengers should create HVAC environment in the automobile interior which is not only for convenient transportation but also give comfortable feeling with dwelling culture. Also, the latest cars give much importance for the role of HVAC system that controls the environment of the area for passengers more than just basic capability. There are solar radiant heat, surface temperature, refrigeration system(temperature, humidity, air current, velocity), and dust for the factor which have an effect on the HVAC environment in the automobile interior, also these are being carried for the HVAC environment delivered an individual character. In this study, we drew the automobile interior as three dimension and arranged a method of numerical analysis on HVAC environment in the automobile interior displaying air current distribution and temperature distribution through simulation of the automobile interior on the ventilation volume and outlet area. The aim of this study is to develop the estimated method for HVAC environment. in the automobile interior.

  • PDF

A Study on Determining the Optimal Stop Time of HVAC System (공조설비 최적 정지시각 결정에 관한 연구)

  • 양인호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.30-37
    • /
    • 2001
  • The purpose of this study is to present the method to determine the optimal stop time of HVAC using Artificial Neural Network model, one of the learning methods. For this, the performance of determining the stop time of HVAC for unexperienced learning data was evaluated, and time interval for measurement of input data and permissible error needed for practical application of ANN model were presented using the results of daily simulation.

  • PDF

Study on Fault Detection System used the Classified Rule-based of HVAC (분류형 규칙기반을 이용한 HVAC 시스템의 고장검출에 관한 연구)

  • Yoo, Seung-Sun;Youk, Sang-Jo;Cho, Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11B
    • /
    • pp.655-662
    • /
    • 2007
  • Monitoring systems used at present to operate HVAC(Heating, Ventilation and Air Conditioning) optimally do not have a function that enables to detect faults properly when there are faults of such as operating plants or performance falling, so they are unable to manage faults rapidly and operate optimally. In this paper, we have developed a classified rule-based fault detection system which can be inclusively used in HVAC system of a building by installation of sensor which is composed of HVAC system and required low costs compare to the model based fault detection system which can be used only in a special building or system. In order to experiment this algorithm, it was applied to HVAC system which is installed inside EC(Environment Chamber), verified its own practical effect, and confirmed its own applicability to the related field in the future.

Evaluation of Noise Reduction Performance of HVAC System for Ships (선박용 HVAC 시스템의 소음저감성능 평가)

  • Kim, Sang-Ryul;kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Lee, Sung-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • In this paper, evaluation of noise reduction performance of HVAC system for ships by means of HVAC mock-up system is presented. Test is done for six different types of HVAC elements including room unit, silencer, etc. It is found that when diameter of silencer is small and air flow is large, flow noise degrades insertion loss. However, as diameter of silencer becomes larger, the effect of flow noise becomes smaller, and insertion loss up to 25 dB is measured. It is observed that insertion loss of diffuser type room unit is usually between zero and 10 dB, whereas that of the nozzle type room unit can be down to - 15 dB. In addition, it is shown that changing duct arrangement can reduce cabin noise by up to 2 dB, and providing same air flow to each room unit is crucial for generating less noise.

HVAC System Design For Saving Energy Sital Daryanani (에너지절약을 위한 HVAC 계통설계)

  • 대한설비공학회
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.2 no.4
    • /
    • pp.271-273
    • /
    • 1973
  • 에너지 사용의 최적화는 건축설비계통의 각 관점을 다른 모든 사항들과 비교고찰하는 (설치비에 대응하는 장기운전 및 정비의 요구사을 고려하는) HVAC계통설계로부터 얻어 진다. 저자는 최상목표인 쾌적과 경제성을 고려해서 전반적으로 각 분야를 집약한 계통설계의 프로그램을 제시하고 있다.

  • PDF

Internet-Based Control and Monitoring System Using LonWorks Fieldbus for HVAC Application

  • Hong, Won-Pyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1205-1210
    • /
    • 2004
  • The 4-20mA analog signal used in the various industrial fields to interface sensor in distributed process control has been replaced with relatively simple digital networks, called "fieldbus, and recently by Ethernet. Significant advances in Internet and computer technology have made it possible to develop an Internet based control, monitoring, and operation scheduling system for heating, ventilation and air-conditioning (HVAC) systems. The seamless integration of data networks with control networks allows access to any control point from anywhere. Field compatible field devices become so-called "smart" devices, capable of executing simple control, diagnostic and maintenance functions and providing bidirectional serial communication to higher level controller. The most important HVAC of BAS has received nationwide attention because of higher portion of more than 40% in building sector energy use and limited resources. This paper presents the Internet-based monitoring and control architecture and development of LonWorks control modules for AHU (air handling units) of HVAC in viewpoint of configuring BAS network. This article addresses issues in architecture section, electronics, embedded processors and software, and internet technologies.

  • PDF

The Characteristics of HVAC Noise in Office Buildings (사무소 건물의 공조설비소음 특성)

  • Do, Young-Ju;Kim, Dong-Gyu;Kim, Heung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.59-66
    • /
    • 1989
  • This study aims to provide the basic data useful in assessing indoor-noise and designing sound devices in office buildings of HVAC system. The measurements of HVAC noise were carried out in office room and mechanical room. The performance of absorptive chamber and side branch was also estimated in the office buildings which have HVAC noise problems. The results of experiments show that the NR value of indoor HVAC noise is rather higher than that of ISO recommendations at the frequencies below 500Hz. In addition, the results indicated that the absorptive chamber attenuates noise over broad band frequencies and side branch reduces noise at the special resonant frequency.

  • PDF

Numerical Analysis on HVAC Characteristics of Train with non-uniform Interior Cross-section (비균일 단면을 가진 철도차량의 내부 열유동 해석)

  • Nam Seong-Won;Kim Hyeong-Jin
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.685-689
    • /
    • 2004
  • Numerical simulation is conducted to clarify the heat transfer and fluid flow characteristics of HVAC(Heating, Ventilating and Air-Conditioning) for double' deck train. The HVAC system is installed under the roof of carbody. In the lay-out of HVAC system, air duct must be installed to supply air to 1st and 2nd floor respectively. The standard k-$\epsilon$ and LES models for turbulence and SIMPLE algorithm for pressure equation hased on finite volume method are used to solve the physic a] HVAC model. To assure convergence, QUICK scheme for momentum equation and the 2nd order upwind scheme for turbulent equations arc used. From the results of simulation, the temperature and velocity magnitude are also distributed uniformly in the interior of double-deck passenger car.

  • PDF