±750[V] 직류배전망의 고장전류 산정에 관한 연구 (A Study on Fault Current Calculation of ±750[V] DC Distribution Grid)

  • 이경민;박철원
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1286-1291
    • /
    • 2018
  • In recent years, the proliferation of DER (distributed energy resources) is progressing rapidly. In particular, research on LVDC distribution grid with various advantages has begun. In order to commercialize this LVDC grid, direct current protection method should be established by analysis of DC faults. Recently, the development of HSCB (high-speed circuit breaker) for new ${\pm}750[V]$ LVDC grid has been researched. This paper deals with the calculation of the maximum short-circuit fault current of the HSCB as a part of the development of HSCB for the LVDC distribution grid. First, modeling using PSCAD was carried out for PV array with BESS on the Gochang Power Test Center system. Next, to calculate the rated capacity of HSCB, fault currents were calculated and the characteristics were analyzed through fault simulations. Thus, this study results can help to establish short-circuit capacity calculation of HSCB and protection plan for DC protection relay system.

전기철도 변전소의 직류고속도차단기 동작 감소방안에 관한 연구 (A Study on the DC High Speed Circuit Breaker(HSCB) in Electric Railway Substation System)

  • 허태복;김학련;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2004
  • This paper proposes a reduction method for the mis-operation analysis of the DC High Speed Circuit Breaker(HSCB) in electric railway substation system. The analysis method is based on present condition of operation which is a method for accuracy level up. There is reason to operation of HSCB that it is mis-operation of fault detection relay(50F), operation of ground fault relay(64P), and trouble of electric car. A countermeasure is relay resetting through field test, induction of GTOCB(Gate Turn Off Thyristor Circuit Breaker), HSVCB(High Speed Vacuum Circuit Breaker), coordination with electric car. The results presented in the paper can be used as a reference for maintenance free in electric railway substation system.

  • PDF

지하철 변전소용 GTO 싸이리스터 차단기 개발 (The Development of GTO circuit breaker for subway substation)

  • 윤재학;최세경;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.524-526
    • /
    • 1997
  • High speed DC circuit breakers (HSCB) are indispensable for protection of DC electric subway substations from fault current. However, the HSCB has mechanical contact to wear, which requires rather frequent maintenance, we have succeeded in developing and manufacturing a GTO DC circuit breaker using GTOs and ZnO varistors. In this paper, we describes the outline of the system itself, its characteristics and test data.

  • PDF

철도 차량용 직류 고속도 차단기의 그리드 특성 해석 (Effects of Grid Characteristics on High Speed Circuit Breaker for Railway Vehicle)

  • 박지원;정주영;최진일
    • 한국철도학회논문집
    • /
    • 제19권2호
    • /
    • pp.117-123
    • /
    • 2016
  • 철도차량용 직류 고속도 차단기(HSCB)는 주 회로에 흐르고 있는 전류를 정상 차단시 아크 슈트 내부에서 발생아크를 소호하여 접지사고를 방지하는 기능으로 사용되고 있다. 선로에 사용되는 접촉기의 개방시에 발생하는 아크를 연구하기 위하여 아크 구현, 외부자계 등에 의한 효과적인 아크 소호의 방식 정립 및 아크 자기 구동력의 해석이 필요하다. 본 논문은 전자접촉기의 정상 차단시 발생하는 아크를 자속밀도 차와 로렌츠력을 통하여 소호능력을 예측하였다. 아크 슈트 내부의 그리드 개수와 형상은 내부 자계 형성에 영향을 미치므로, 유한 요소법을 이용하여 그리드의 변화에 따른 아크 소호능력을 연구하였으며 정격전압에 따른 그리드의 소호능력 평가와 그리드 형상 특성을 해석하였다.

경량전철 급전전력 보호 제어용 직류배전반 개발(I) (Development of DC switch gear for LRT system protection and control( I ))

  • 김남해;백병산;전용주;김지홍;이병송;김종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.995-1000
    • /
    • 2002
  • This paper presents general concept of DC switch gear(DCSWGR). Normally, DCSWGR consist of Digital protection unit(DPU), High Speed Circuit Breaker(HSCB), Disconnect Switch (DS), Programmable Logic Control(PLC), Auxiliary Relays and etc. Most of the components has its special characteristics and their interface between each others are various and complex. In this paper every constituent general design are preceded and interface between each component are examined. And also DCSWGR operation logic with logical diagram including interlock signal are introduced.

  • PDF

DC 급전케이블 지락사고 보호방안에 관한 연구 (The study on the prevention of DC feeder line cable grounding fault)

  • 박지수;송중호;박정욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.202-207
    • /
    • 2008
  • This study provides review and improvement plans for the possible problems caused when the CV cable is used as a positive feeder line which supplies power from the DC HSCB (high-speed circuit breaker) to the catenariesin Seoul Metro which is using direct-current feeder method. In detail, this study contributes to stabilizing the power line by triggering a protective device by instantly detecting potential rise which happens when grounding fault occurs in non-grounding type CV cable shield.

  • PDF

직류고속도차단기의 소전류 차단 특성연구 (The Characteristic Study for Small Current Breaking of High Speed DC Circuit Breaker)

  • 민병훈;장우진;고인석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권8호
    • /
    • pp.396-402
    • /
    • 2006
  • Even the case DC circuit Breaker have good quality for interruption of high current like heavy load current, short-circuit current, the verification for small current breaking capability of circuit breaker should be performed. It comes from the reason DC small current breaking failure can be lead to break out second heavy fault condition and in the long run substation shutdown. In this paper, we can find the characteristics of DC small current and international test standard discription about small current breaking and one of the proper solution to get over it.

AGT 경량전철 전력공급용 직류배전반 개발 (Development of DCSWGR for AGT Light Rail Power Supply System)

  • 전용주;김수남;백병산;김지홍;이현두;권중록;정상기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1391-1393
    • /
    • 2004
  • This paper described the development of technology for LRT (Light Rail Transit) power system, which are sponsored by MOCT and supervised by KRRI. Especially, manufacture, interface between components and composition for DC Switchgear are focused. Most main components for DC switchgear(Protective Relay, HSCB, DS) are made by own. Also the type test report of international testing laboratory about the DC Switchgear based on IEC regulations is introduced. Finally the product will be proved based on field test.

  • PDF

전동차 고속차단기 고장 분석을 위한 FMECA 기법 (FMECA Procedure for Failure Analysis of Train High-Speed Circuit Breaker)

  • 김성렬;문용선;최규형
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3370-3377
    • /
    • 2015
  • 전동차는 대용량 교통수단으로서 정시 운행 및 높은 안전성이 요구되기 때문에, 고장 분석을 체계적으로 수행하여 신뢰도를 향상시키기 위한 수단으로서 고장 영향의 심각도 및 치명도를 정량적으로 평가하는 FMECA (Failure Modes, Effects and Criticality Analysis) 기법이 적용되고 있다. 그러나, 아직까지 전동차에 특화된 FMECA 규격 및 절차는 정립되어 있지 않고 자동차 산업 등 다른 산업분야의 FMECA 규격을 그대로 적용하고 있기 때문에 전동차의 고유한 운영 및 유지보수 여건을 충분히 반영하지 못하고 있다. 본 논문에서는 산업계 각 분야에서 적용되고 있는 FMECA 규격에 대한 분석을 토대로, 전동차 분야에 적합한 FMECA 기법으로서 고장 영향 분석과 치명도 분석을 단계별로 나누어 수행하고 고장 영향의 심각도에 중점을 두어 치명도를 분석하는 기법을 제시하였다. 제안 기법을 전동차의 핵심 안전 장치인 고속차단기에 적용하여 도시철도 현장에서의 15년 동안의 전동차 유지보수 데이터를 이용하여 분석한 결과, 고속차단기 부품 중에서 특히 아크 슈트의 절손이 심각도 3등급, 치명도 5등급으로 위험도가 가장 높았으며, 뒤를 이어서 전자변 파손 및 접촉 불량, 실린더 파손 등이 심각도 3등급, 치명도 4등급으로 위험도가 높은 것으로 나타났다. 이상의 분석 결과는 전동차 고속차단기의 설계 및 유지보수 업무의 개선에 활용할 수 있다.