• Title/Summary/Keyword: HR reconstruction

Search Result 27, Processing Time 0.033 seconds

Reconstruction of HR by POCS and Regularized Block Matching (정규화된 블록매칭과 POCS에 의한 HR 영상 재구성)

  • Choi Jong-Beom;Oh Tae-Seok;Kim Yong Cheo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.8C
    • /
    • pp.824-831
    • /
    • 2005
  • In the reconstruction of high resolution (HR) images from low resolution (LR) images frames, the error in the estimated motion degrades the reliability of the reconstructed HR image. Some methods were recently proposed where motion estimation and HR reconstruction is performed simultaneously. The estimated motion is still prone to error when it is based on a simple block matching. In this paper, we propose a reconstruction of a HR image by applying POCS and a regularized block matching simultaneously. In this method, a motion vector is obtained from a regularized block matching algorithm since the motion of a pixel in an image is highly correlated with the motion in neighboring regions. Experimental results show that the improved accuracy of the estimated motion vectors results in higher PSNR of the reconstructed HR images.

Reconstruction of High Resolution Images by ARPS Motion Estimation and POCS Restoration (ARPS 움직임 추정과 POCS 복원을 동시에 이용하는 HR 영상 재구성)

  • Song, Hee-Keun;Kim, Yong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.3C
    • /
    • pp.288-296
    • /
    • 2009
  • In POCS (projection onto convex sets)-based reconstruction of HR (high resolution) image, the quality of reconstructed image is gradually improved through iterative motion estimation and image restoration. The amount of computation, however, increases because of the repeated inter-frame motion estimation. In this paper, an HR reconstruction algorithm is proposed where modified ARPS (adaptive rood pattern search) and POCS are simultaneously performed. In the modified ARPS, the motion estimates obtained from phase correlation or from the previous steps in POCS restoration are utilized as the initial reference in the motion estimation. Moreover, estimated motion is regularized with reference to the neighboring blocks' motion to enhance the reliability. Computer simulation results show that, when compared to conventional methods which are composed of full search block matching and POCS restoration, the proposed method is about 30 times faster and yet produces HR images of almost equal or better quality.

SUPER RESOLUTION RECONSTRUCTION FROM IMAGE SEQUENCE

  • Park Jae-Min;Kim Byung-Guk
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.197-200
    • /
    • 2005
  • Super resolution image reconstruction method refers to image processing algorithms that produce a high resolution(HR) image from observed several low resolution(LR) images of the same scene. This method is proved to be useful in many practical cases where multiple frames of the same scene can be obtained, such as satellite imaging, video surveillance, video enhancement and restoration, digital mosaicking, and medical imaging. In this paper we applied super resolution reconstruction method in spatial domain to video sequences. Test images are adjacently sampled images from continuous video sequences and overlapped for high rate. We constructed the observation model between the HR images and LR images applied by the Maximum A Posteriori(MAP) reconstruction method that is one of the major methods in the super resolution grid construction. Based on this method, we reconstructed high resolution images from low resolution images and compared the results with those from other known interpolation methods.

  • PDF

A Study on Super Resolution Image Reconstruction for Effective Spatial Identification

  • Park Jae-Min;Jung Jae-Seung;Kim Byung-Guk
    • Spatial Information Research
    • /
    • v.13 no.4 s.35
    • /
    • pp.345-354
    • /
    • 2005
  • Super resolution image reconstruction method refers to image processing algorithms that produce a high resolution(HR) image from observed several low resolution(LR) images of the same scene. This method has proven to be useful in many practical cases where multiple frames of the same scene can be obtained, such as satellite imaging, video surveillance, video enhancement and restoration, digital mosaicking, and medical imaging. In this paper, we applied the super resolution reconstruction method in spatial domain to video sequences. Test images are adjacently sampled images from continuous video sequences and are overlapped at high rate. We constructed the observation model between the HR images and LR images applied with the Maximum A Posteriori(MAP) reconstruction method which is one of the major methods in the super resolution grid construction. Based on the MAP method, we reconstructed high resolution images from low resolution images and compared the results with those from other known interpolation methods.

  • PDF

An Improved Input Image Selection Algorithm for Super Resolution Still Image Reconstruction from Video Sequence (비디오 시퀀스로부터 고해상도 정지영상 복원을 위한 입력영상 선택 알고리즘)

  • Lee, Si-Kyoung;Cho, Hyo-Moon;Cho, Sang-Bok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.18-23
    • /
    • 2008
  • In this paper, we propose the input image selection-method to improve the reconstructed high-resolution (HR) image quality. To obtain ideal super-resolution (SR) reconstruction image, all input images are well-registered. However, the registration is not ideal in practice. Due to this reason, the selection of input images with low registration error (RE) is more important than the number of input images in order to obtain good quality of a HR image. The suitability of a candidate input image can be determined by using statistical and restricted registration properties. Therefore, we propose the proper candidate input Low Resolution(LR) image selection-method as a pre-processing for the SR reconstruction in automatic manner. In video sequences, all input images in specified region are allowed to use SR reconstruction as low-resolution input image and/or the reference image. The candidacy of an input LR image is decided by the threshold value and this threshold is calculated by using the maximum motion compensation error (MMCE) of the reference image. If the motion compensation error (MCE) of LR input image is in the range of 0 < MCE < MMCE then this LR input image is selected for SR reconstruction, else then LR input image are neglected. The optimal reference LR (ORLR) image is decided by comparing the number of the selected LR input (SLRI) images with each reference LR input (RLRI) image. Finally, we generate a HR image by using optimal reference LR image and selected LR images and by using the Hardie's interpolation method. This proposed algorithm is expected to improve the quality of SR without any user intervention.

  • PDF

Effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield units of hydroxyapatite in virtual monochromatic images obtained with dual-energy CT

  • Jeong, Dae-Kyo;Lee, Sam-Sun;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.273-279
    • /
    • 2019
  • Purpose: This study was performed to investigate the effects of energy level, reconstruction kernel, and tube rotation time on Hounsfield unit (HU) values of hydroxyapatite (HA) in virtual monochromatic images (VMIs) obtained with dual-energy computed tomography (DECT)(Siemens Healthineers, Erlangen, Germany). Materials and Methods: A bone density calibration phantom with 3 HA inserts of different densities(CTWATER®; 0, 100, and 200 mg of HA/㎤) was scanned using a twin-beam DECT scanner at 120 kVp with tube rotation times of 0.5 and 1.0 seconds. The VMIs were reconstructed by changing the energy level (with options of 40 keV, 70 keV, and 140 keV). In order to investigate the impact of the reconstruction kernel, virtual monochromatic images were reconstructed after changing the kernel from body regular 40 (Br40) to head regular 40 (Hr40) in the reconstruction phase. The mean HU value was measured by placing a circular region of interests (ROIs) in the middle of each insert obtained from the VMIs. The HU values were compared with regard to energy level, reconstruction kernel, and tube rotation time. Results: Hydroxyapatite density was strongly correlated with HU values(correlation coefficient=0.678, P<0.05). For the HA 100 and 200 inserts, HU decreased significantly at increased energy levels(correlation coefficient= -0.538, P<0.05) but increased by 70 HU when using Hr40 rather than Br40 (correlation coefficient=0.158, P<0.05). The tube rotation time did not significantly affect the HU(P>0.05). Conclusion: The HU values of hydroxyapatite were strongly correlated with hydroxyapatite density and energy level in VMIs obtained with DECT.

Reconstruction of Vacancy Defects in Graphene and Carbon Nanotube

  • Lee, Gun-Do;Yoon, Eui-Joon;Hwang, Nong-Moon;Wang, Cai-Zhuang;Ho, Kai-Ming
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.340-340
    • /
    • 2010
  • Various structures of vacancy defects in graphene layers and carbon nanotubes have been reported by high resolution transmission electron microscope (HR-TEM) and those arouse an interest of reconstruction processes of vacancy defects. In this talk, we present reconstruction processes of vacancy defects in a graphene and a carbon nanotube by tight-binding molecular dynamics (TBMD) simulations and by first principles total energy calculations. We found that a structure of a dislocation defect with two pentagon-heptagon (5-7) pairs in graphene becomes more stable than other structures when the number of vacancy units is ten and over. The simulation study of scanning tunneling microscopy reveals that the pentagon-heptagon pair defects perturb the wavefunction of electrons near Fermi level to produce the $\sqrt{3}\;{\times}\;\sqrt{3}$ superlattice pattern, which is in excellent agreement with experiment. It is also observed in our tight-binding molecular dynamics simulation that 5-7 pair defects play a very important role in vacancy reconstruction in a graphene layer and carbon nanotubes.

  • PDF

Risk Factors for Gallstone Formation after Surgery for Gastric Cancer

  • Park, Dong Jin;Kim, Ki Hyun;Park, Young Suk;Ahn, Sang-Hoon;Park, Do Joong;Kim, Hyung-Ho
    • Journal of Gastric Cancer
    • /
    • v.16 no.2
    • /
    • pp.98-104
    • /
    • 2016
  • Purpose: The incidence of gallstones after gastrectomy for gastric cancer is higher than in the general population. However, the causes and mechanisms of post-gastrectomy gallstones are unclear. The aim of this study was to evaluate the incidence of gallstone formation and the risk factors for their development after gastrectomy for gastric cancer. Materials and Methods: Of 1,744 gastric cancer patients who underwent gastrectomy at Seoul National University Bundang Hospital between January 2010 and December 2012, 1,284 were included in this study and retrospectively reviewed. Patients' age, sex, body mass index (BMI), tumor location, stage, type of gastrectomy, type of reconstruction, and extent of node dissection were evaluated. Results: The incidence of gallstones after gastrectomy for gastric cancer was significantly higher in men than in women (P=0.019). Exclusion of the duodenum during reconstruction was associated with a significantly higher incidence of gallstones (P=0.003). Overweight and obese patients with BMI ${\geq}23kg/m^2$ had significantly higher incidence of gallstones than those with a lower BMI (P=0.006). Multivariate analysis showed that obesity (hazard ratio, HR=1.614; 95% confidence interval, CI: 1.135~2.296; P=0.008), male sex (HR=1.515, 95% CI: 1.029~2.231, P=0.033), and exclusion of the duodenum (HR=1.648, 95% CI: 1.192~2.280, P=0.003) were significant, independent risk factors for gallstones after gastrectomy. Conclusions: The cumulative incidence of gallstones for 5 years after gastrectomy was 15.3%. Male sex, obesity, and exclusion of the duodenum were risk factors for gallstone formation after gastrectomy. Careful surveillance will be required for these patient groups after gastrectomy.

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

Glucosylation of Isoflavonoids in Engineered Escherichia coli

  • Pandey, Ramesh Prasad;Parajuli, Prakash;Koirala, Niranjan;Lee, Joo Ho;Park, Yong Il;Sohng, Jae Kyung
    • Molecules and Cells
    • /
    • v.37 no.2
    • /
    • pp.172-177
    • /
    • 2014
  • A glycosyltransferase, YjiC, from Bacillus licheniformis has been used for the modification of the commercially available isoflavonoids genistein, daidzein, biochanin A and formononetin. The in vitro glycosylation reaction, using UDP-${\alpha}$-D-glucose as a donor for the glucose moiety and aforementioned four acceptor molecules, showed the prominent glycosylation at 4' and 7 hydroxyl groups, but not at the $5^{th}$ hydroxyl group of the A-ring, resulting in the production of genistein 4'-O-${\beta}$-D-glucoside, genistein 7-O-${\beta}$-D-glucoside (genistin), genistein 4',7-O-${\beta}$-D-diglucoside, biochanin A-7-O-${\beta}$-D-glucoside (sissotrin), daidzein 4'-O-${\beta}$-D-glucoside, daidzein 7-O-${\beta}$-D-glucoside (daidzin), daidzein 4', 7-O-${\beta}$-D-diglucoside, and formononetin 7-O-${\beta}$-D-glucoside (ononin). The structures of all the products were elucidated using high performance liquid chromatography-photo diode array and high resolution quadrupole time-of-flight electrospray ionization mass spectrometry (HR QTOF-ESI/MS) analysis, and were compared with commercially available standard compounds. Significantly higher bioconversion rates of all four isoflavonoids was observed in both in vitro as well as in vivo bioconversion reactions. The in vivo fermentation of the isoflavonoids by applying engineered E. coli $BL21(DE3)/{\Delta}pgi{\Delta}zwf{\Delta}ushA$ overexpressing phosphoglucomutase (pgm) and glucose 1-phosphate uridyltransferase (galU), along with YjiC, found more than 60% average conversion of $200{\mu}M$ of supplemented isoflavonoids, without any additional UDP-${\alpha}$-D-glucose added in fermentation medium, which could be very beneficial to large scale industrial production of isoflavonoid glucosides.