• 제목/요약/키워드: HPS

검색결과 153건 처리시간 0.041초

Cumin(Cuminum cymium L.) seed로부터 정제한 $2-hydroxyethyl-{\beta}-undecenate$의 항치주염 효과의 효소학적 평가 (Enzymatic Assessment of $2-Hydroxyethyl-{\beta}-undecenate$ Purified from Cumin (Cuminum cymium L.) Seed for Anti-periodontitis)

  • 류일환;강은주;이갑상;박정순
    • 한국식품과학회지
    • /
    • 제39권6호
    • /
    • pp.669-675
    • /
    • 2007
  • 본 연구자들은 Cumin(Cuminum cymium L.) seed로부터 정제한 $2-hydroxyethyl-{\beta}-undecenate$의 항치주염 활성을 사람의 백혈구를 이용하여 염증 매개물질 $LTB_4$ 및 PGs의 생성 효소인 5-lipoxygenase와 cyclooxygenase, 및 조직파괴 효소인 collagenase와 elastase의 저해 효과를 규명하여 다음과 같은 결론을 얻었다. HPS의 항치주염 활성을 사람의 백혈구를 이용하여 염증 매개물질 $LTB_4$ 및 PGs의 생성 효소인 5-lipoxygenase와 cyclooxygenase 및 조직파괴효소인 collagenase와 elastase의 저해효과를 규명한 결과, HPS은 $5\;{\times}\;10^{-2}\;M$ 첨가 시 97%의 PMNL로부터 $LTB_4$ 생합성이 저해되었으며 이때 $IC_{50}$ 값은 $2\;{\times}\;10^{-4}\;M$ 이었다. 균질화된 사람의 PMNL 5-lipoxygenase 및 시판 정제 5-lipoxygenase 활성에 대한 HPS의 저해 효과는 $5\;{\times}\;10^{-2}\;M$첨가 시 92%의 효소 활성이 저해되었다. 또한 효소 활성에 대한 $IC_{50}$ 값은 $2.5\;{\times}\;10^{-4}\;M$이었으며, 정제 5-lipoxygenase에 대한 $IC_{50}$ 값은 $2.3\;{\times}\;10^{-4}\;M$이었다. 또한 백혈구 COX 활성에 대한 $IC_{50}$ 값은 $5.1\;{\times}\;10^{-4}\;M$이었고, 정제 COX에 대한 $IC_{50}$ 값은 $2.3\;{\times}\;10^{-4}\;M$이었으며, 백혈구 collagenase 활성에 대한 $IC_{50}$ 값은 $2\;{\times}\;10^{-3}\;M$이었고 정제 collagenase에 대한 $IC_{50}$ 값은 $5\;{\times}\;10^{-2}\;M$이었다. 백혈구 elastase의 경우 $5\;{\times}\;10^{-2}\;M$ 첨가 시 66%의 활성이 저해된 반면 정제 elastase의 경우 $5\;{\times}\;10^{-2}\;M$ 첨가 시 25%의 효소 활성이 저해되었다. 또한 백혈구 elastase 활성에 대한 $IC_{50}$ 값은 $7.5\;{\times}\;10^{-3}\;M$이었다. 인체 치은세포에 대한 독성 시험 결과 $5\;{\times}\;10^{-2}\;M$의 HPS 첨가시 세포의 활성은 배양 2일째 47.83%로 나타났으며, $1\;{\times}\;10^{-2}\;M$의 HPS 첨가시에도 68.53%로 나타나 비교적 세포독성이 강한 것으로 나타났다.

WHO 건강증진학교 평가개념을 적용한 사정 및 평가 - 앙평군 초.중.고등학교별 차이 분석 - (Evaluating Health-Promoting Schools Based on WHO Standards in Yangpyung-Gun, Korea)

  • 손애리;김보람;김석현;신영전;안동현;최보율
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제9권1호
    • /
    • pp.1-15
    • /
    • 2008
  • Objectives: The concept of the WHO's 'Health Promoting School (HPS)' has been advocated as an approach enhancing national health promotion through school. Health-promoting schools have existed internationally about 20 years. Yet there are few comprehensive evaluation results. Methods: This study is a cross-sectional survey, aiming to explore the HPS status. A total of 31 elementary, middle and high schools were included, and 260 teachers participated in the study. The schools were assessed based on tools of HPS. Results: 'School health promotion and protection services' and 'school's physical environment' had the highest scores, 80.7 score and 77.4 score, respectively. Community links and action competencies for healthy living were two areas with the lowest scores. Conclusions: These results are a good source of reference for assessment and evaluation of Health Promoting Schools programs. For the improvement of efficiency of Health Promoting Schools programs, cooperation with family and community link and support system would be necessary.

  • PDF

고분자 전해질 연료전지용 Sulfonated Poly(ether sulfone)의 합성 및 특성 평가 (Synthesis and Characterization of Mono-sulfonated Poly(ether sulfone) for a Fuel Cell Application)

  • ;김형준;;조은애;오인환;홍성안;임태훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.235-238
    • /
    • 2005
  • Sulfonated poly(ether sulfone) copolymers (PESs) were synthesized using hydroquinone 2-potassium sulfonate (HPS) with other monomers (bisphenol A and 4-fluorophenyl sulfone). PESs with different $mole\%$ of hydrophilic group were prepared by changing the mole ratio of HPS in the polymerization reaction. The chemical structure and the thermal stability of these polymers were characterized by using $^1H-NMR$, FT-IR and TGA techniques. The PES 60 membrane, which has $60 mole\%$ of HPS unit in the polymer backbone, has a proton conductivity of 0.091 S/cm and good insolubility in boiling water. The TGA showed that PES 60 was stable up to $272^{\circ}C$ with a char yield of about $29\%\;at\;900^{\circ}C\;under\;N_2$ atmosphere. To investigate the single cell performance, the catalyst coated PES 60 membrane was used and a single cell test was carried out using $H_2/O_2$ gases as fuel and oxidant at various temperatures. We observed that the cell performance was enhanced by increasing the cell temperature. A current density of $1400 mA/cm^2$ at 0.60 V was obtained at $70^{\circ}C$.

  • PDF

SoC FPGA 기반 실시간 객체 인식 및 추적 시스템 구현 (An Implementation of SoC FPGA-based Real-time Object Recognition and Tracking System)

  • 김동진;주연정;박영석
    • 대한임베디드공학회논문지
    • /
    • 제10권6호
    • /
    • pp.363-372
    • /
    • 2015
  • Recent some SoC FPGA Releases that integrate ARM processor and FPGA fabric show better performance compared to the ASIC SoC used in typical embedded image processing system. In this study, using the above advantages, we implement a SoC FPGA-based Real-Time Object Recognition and Tracking System. In our system, the video input and output, image preprocessing process, and background subtraction processing were implemented in FPGA logics. And the object recognition and tracking processes were implemented in ARM processor-based programs. Our system provides the processing performance of 5.3 fps for the SVGA video input. This is about 79 times faster processing power than software approach based on the Nios II Soft-core processor, and about 4 times faster than approach based the HPS processor. Consequently, if the object recognition and tracking system takes a design structure combined with the FPGA logic and HPS processor-based processes of recent SoC FPGA Releases, then the real-time processing is possible because the processing speed is improved than the system that be handled only by the software approach.

간호대학생 대상 한국판 의료계열 학생용 제퍼슨 공감 척도의 신뢰도 및 타당도 검증 (Validation Study of the Korean Version of the Jefferson Scale of Empathy-Health Professions Students for Measuring Empathy in Undergraduate Nursing Students)

  • 김지순;안숙희
    • 한국간호교육학회지
    • /
    • 제24권3호
    • /
    • pp.259-268
    • /
    • 2018
  • Purpose: This study was to validate the Korean version of the Jefferson Scale of Empathy-Health Professions Students (K-JSE-HPS) in undergraduate nursing students. Methods: With a survey design, a total of 293 junior and senior nursing students were recruited and data were collected using a self-administered study questionnaire to measure their levels of empathy use the K-JSE-HPS. Using SPSS/WIN 22.0 and AMOS 22.0, data analysis was conducted with confirmatory factor analysis, criterion validity, and reliability. Results: For construct validity, confirmatory factor analysis showed an acceptable model fit (Goodness of Fit Index was 0.88) along with confirming convergent and discriminant validity (construct reliability was 0.70). For criterion validity, the scale was significantly related with the Interpersonal Reaction Index. For reliability, Cronbach's ${\alpha}$ coefficient for the scale was 0.87 and for the subscales were 0.84, 0.78, and 0.69, respectively. Conclusion: The findings show satisfactory construct and criterion validity and reliability of the Korean version of the JSE-HPS for measuring empathy in undergraduate nursing students.

과학기술위성 3호 홀추력기 추진계 개발 (STSAT-3 Hall Thruster Propulsion System Development)

  • 조희근;유광선;차원호;이종섭;서미희;최원호;명로훈
    • 한국항공우주학회지
    • /
    • 제38권8호
    • /
    • pp.834-841
    • /
    • 2010
  • 최신기술이 적용된 전구조 복합재 위성인 과학기술위성 3호 (STSAT-3)가 국내 최초로 개발 되었으며 2011년 발사예정이다. 모든 위성과 마찬가지로 과기 3호에는 다수의 탑재체가 탑재될 예정이며 그 주된 목적은 선진 우주기술의 과학적 검증에 있다. 제논 가스를 연료로 하는 홀추력기가 국내 최초로 개발되어 지상시험을 거친 후 과기3호에 탑재되었다. 본 연구는 홀추력기 개발에 적용된 전반적인 개발기술, 절차, 기능 및 환경시험에 대한 내용이며 선진 우주기술 획득 및 차후 위성개발을 위한 기술자료 축적에 그 중요성이 있다.

RCD 스너버 및 준구형파를 이용한 250[W] HPS lamp용 전자석 안정기 개발 (The Development Of the Electronic Ballast for HPS lamp using the RCD Snubber and Quasi-Square Wave)

  • 강도형;박종연
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.18-25
    • /
    • 2002
  • 본 논문은 고압 방전램프를 점등시켜 주는 전자식 안정기에 관한 것으로서, Class D LCC 공진 인버터 방식을 이용하여, 램프의 초기 점등, 정상상태를 구동하게 하고, 준구형파로 ZC-ZVS Soft Switching을 구현하여 풀-브리지 스위치의 발열을 최소화할 수 있도록 하였다. 또한, RCD 스너버 회로를 적용하여 스위치 발열 감소뿐만 아니라, 고주파 스위칭으로 인한 서지 전압의 감소를 통한 노이즈를 최소화시켜 제어부의 안정되고, 신뢰성 있는 동작을 가능하게 할 수 있도록 하고, 안정기의 전체적인 스위칭 노이즈 발생을 최소화하였다.

X-밴드 완전 편파 Scatterometer 시스템 보정에 관한 연구 (Study on the Calibration of a Full-Polarimetric Scatterometer System at X-band)

  • 황지환;박성민;권순구;오이석
    • 한국전자파학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-416
    • /
    • 2010
  • 본 논문에서는 X-밴드 대역의 지상운용용 HPS(Hongik Polarimetric Scatterometer) 시스템 보정에 관한 연구 결과를 선보인다. Scatterometer 시스템 보정을 위해 이론적으로 RCS(Radar Cross Section)가 잘 알려진 금속구, 삼각수동 반사기(trihedral corner reflector), 금속봉 등과 같은 보정용 목표물을 이용하여 이론값과 측정값을 비교함으로써 scatterometer 시스템의 왜곡 정도를 분석한다. 실외 환경에서 scatterometer 시스템을 이용하는 실제 측정상황의 보정 정확도는 보정용 목표물의 정확하고 안정된 측정에 의해 좌우되므로 이를 보완하기 위해 HPS 시스템의 입사각(${\xi}-$, ${\phi}-$방향) 제어 기능을 응용한 자동화된 2차원 목표물 스캐닝 측정법(2-D target scanning technique) 을 함께 선보인다. 이때, scatterometer 시스템의 왜곡 정도를 보정하기 위한 기법으로는 GCT(General Calibration Technique) 기법과 STCT(Single Target Calibration Technique) 기법을 비교 연구하였으며, 보정 정확도를 분석하기 위해서 시험용 목표물로 삼각 수동 반사기의 편파별 RCS와 위상차를 측정/비교하였다. 시스템 보정 정도를 검증하기 위해 세 종류(10/20/30 cm)의 삼각수동 반사기를 이용하였으며, 동일 편파 RCS는 GCT 기법과 STCT 기법을 이용하여 각각 ${\pm}1.0$ dB과 ${\pm}0.5$ dB의 오차 범위에서 보정되었다. 또한, 동일 편파간 위상차( ${\phi}_{hh}-{\phi}_{vv}$)는 이론 값과 비교하여 $-20^{\circ}{\sim}0^{\circ}$와 약 ${\pm}5^{\circ}$의 오차를 각각 보였다.

Bacillus clausii I-52의 Chromosomal Integration에 의한 Alkaline Protease의 생산성 향상 (Increased Production of an Alkaline Protease from Bacillus clausii I-52 by Chromosomal Integration)

  • 주한승;박동철;최장원
    • 농업생명과학연구
    • /
    • 제46권1호
    • /
    • pp.163-176
    • /
    • 2012
  • 인천 연안 갯벌에서 분리한 호알카리성 Bacillus clausii I-52로부터 세포외 알카리성 단백질 분해효소(BCAP)의 발현 및 생산성을 증가시키기 위하여 BCAP promoter, ribosome 결합 서열, 신호서열, 전구체 서열 및 활성형 BCAP 유전자를 cloning한 재조합 plasmid pHPS9-fuBCAP을 penicillin-protoplast 법으로 B. clausii I-52의 염색체 DNA에 integration 하였고, 도입된 plasmid pHPS9-fuBCAP 유전자는 PCR에 의해 확인하였다. 가장 높은 단백질 분해효소 상대 활성을 보이는 선별된 transformant C5를 생산 최적화 배지(대두박 2%, 밀가루 1%, 구연산나트륨 0.5%, $K_2HPO_4$ 0.4%, $Na_2HPO_4$ 0.1%, NaCl 0.4%, $MgSO_47H_2O$ 0.01%, $FeSO_47H_2O$ 0.05%, 물엿 2.5%, 탄산나트륨 0.6%)에서 액침 배양법(배양온도, $37^{\circ}C$; 배양 시간, 48 h; 교반 속도, 650 rpm; 통기 속도, 1 vvm)으로 배양하여 단백질 분해효소를 발현 및 분비시켰을 때, BCAP 발현 양(134,670 U/ml)은 wild-type(83,960 U/ml)에 비하여 약 1.6 배 증가하였으며, 비활성도(91,611.5 U/mg 단백질)는 wild-type(71,760 U/mg 단백질)에 비하여 약 1.3 배 증가하였다. 또한, B. clausii I-52 염색체 DNA에 integration된 pHPS9-fuBCAP plasmid는 단백질 발현과 함께 8일간의 계대배양 동안에 안정하게 유지되고 있음을 확인하였다.

고압나트륨등 보광 온실의 열적 거동 및 엽온 분석 (Thermal Behavior and Leaf Temperature in a High Pressure Sodium Lamp Supplemented Greenhouse)

  • 윤승리;김진현;신민주;김동필;방지웅;정호정;안태인
    • 생물환경조절학회지
    • /
    • 제32권1호
    • /
    • pp.48-56
    • /
    • 2023
  • 고압나트륨등(high-pressure sodium, HPS 램프)은 작물 생육 발달에 필요한 충분한 양의 광합성유효방사를 제공하는 동시에 복사열을 통해 온실 난방 부하를 절감할 수 있어 겨울철 시설원예 보광 조명으로 널리 이용되고 있다. 그러나 겨울철에 생육 중기를 맞이하는 시설 과채류의 경우, 작물의 정단부가 복사열에 영향을 많이 받고, 캐노피 위치에 따라 엽온 차이가 증가될 수 있다. 또한 온실 기온 역시 보광등에서 발생한 열이 상부로 상승 및 정체되면서 불필요한 에너지 낭비 및 온도 불균일성 역시 심화될 수 있다. 따라서 본 연구의 목표는 CFD 열전달 해석을 통해 HPS 램프에 의한 열적 특성 및 생육 단계별 수평적 엽온 변화를 분석하고, 온실 내 수직적 기온 및 작물의 캐노피별 엽온을 측정하여, 온실 내 환경 균일성 제고 및 효과적 에너지 활용 방안을 모색하는 것이었다. 생육 초기, 중기, 및 후기를 대변하는 초장(1.0, 1.6, 2.2m)에서의 정단부 수평적 엽온을 CFD 시뮬레이션을 통해 분석하였다. 또한 HPS 램프 작동 이후 수직적 기온과 캐노피 높이별 엽온을 측정하였다. 실험 결과, 보광 시 엽온과 기온 간의 차이가 커지고, 수직적 기온 역시 불균일해짐을 알 수 있었다. 생육 단계가 진전될수록, 고온의 복사열이 중심부에 집중되며, 상단부 수평적 엽온 편차가 커지고, 균일성 역시 떨어지는 것을 알 수 있었다. 열획득 모델을 통한 수치해석 결과, 보광등이 2022년12월 기간 난방부하에 약 50.1% 기여하는 것을 알 수 있었다. 평균절대오차 및 평균제곱근 오차는 생육 초기 및 생육 중기 모두0.5 이하로, 실측값과 예측값에 높은 일치도를 보였다. 수직적 기온 및 엽온 분포와 생육 단계별 수평적 엽온 분포에 관한 본 연구의 결과는 효율적 에너지 관리 및 작물 생육 발달에 관한 의사결정에 도움이 될 수 있을 것으로 생각된다.