Sesamin and sesamolin, antioxidant lipidsoluble lignan compounds, are abundant in sesame (Sesamum indicum L.) seed oil and provide oxidative stability of oil related to sesame quality. The sesamin and sesamolin contents of 403 sesame land races of Korea were determined by HPLC analysis of methanol extract (HPLC value), and their total lignan content was compared with those by using UV-Vis spectrophotometric analysis (UV method) of methanol (UV-MeOH value) and hexane (UV-Hexane value) extracts. HPLC values of total lignan content were strongly associated with UV-Hexane (r=0.705**) and UV-MeOH (r=0.811**) values. The UV values from both the extracts were 3.8-4.7 times higher than those of HPLC values. Lignan content was overestimated by UV method because total compounds in the mixture solution were quantified by absorbing at the same ultraviolet wavelength as in HPLC method. UV method could more rapidly analyze small amount of sample with higher sensitivity of detection than HPLC method. Average contents of lignans in sesame germplasm evaluated in this study were $2.09{\pm}1.02mg/g$ of sesamin, and $1.65{\pm}0.61mg/g$ of sesamolin, respectively, showing significant variation for lignan components. The results showed that UV method for the determination of sesamin and sesamolin could be practically used as a faster and easier method than HPLC by using the regression equations developed in this study.
The aim of this study was to evaluate the difference of analytical methods for the pharmacokinetic study of bromosulfophthalein (BSP), an indicator of hepatobiliary function. The plasma and bile concentrations of BSP after intravenous administration were measured according to custom UV spectroscopy and HPLC, respectively. Plasma concentration of BSP measured by UV spectroscopy was similar to that measured by HPLC. There was no significant difference in the distribution volume, total body clearance, area under the curve and mean residence time of BSP between different analytical method groups. However, bile concentration of BSP measured by UV spectroscopy was overestimated compared with concentration measured by HPLC method. Biliary clearance of BSP obtained from UV spectroscopy method was almost 3 times higher than that obtained from HPLC method. Thus, a feasibility of UV spectroscopy method for high throughput pharmacokinetic evaluation of BSP was limited to the study based on the plasma concentration of BSP, not bile concentration.
To assess accurate methods for measuring sulfur dioxide residue in pickles, the acid distillation HPLC-UV method and Monnier Willams modified method were examined. By the acid distillation HPLC-UV method, sulfites released from pickles by acid distillation were absorbed in 1% triethanolamine solution and detected as sulfite ion by HPLC with UV monitoring at 240nm. An anion exchange column was employed with 1.8mM $Ma_2CO_3-1.7mM\;NaHCO_3$ solution as a mobile phase, $84.0{\sim}91.7%$ of sulfite added to pickled radish were recovered. Total sulfite levels from 48 kinds of pickles analyzed by acid distillation HPLC-UV was compared with those analyzed by the Monnier Williams modified method. The Monnier Williams modified method showed higher levels of sulfur dioxide than the acid distillation HPLC-UV method due to the presence of volatile acids in pickles. The concentration of sulfur dioxide was in the range of $N.D{\sim}173.05ppm$ in pickled radish and over 30ppm of sulfur dioxide from 3 samples by the acid distillation-HPLC-UV method.
Jeong, Su Yang;Zhao, Bing Tian;Moon, Dong Cheul;Kang, Jong Seong;Lee, Je Hyun;Min, Byung Sun;Son, Jong Keun;Woo, Mi Hee
Natural Product Sciences
/
v.19
no.1
/
pp.28-35
/
2013
In this study, quantitative and pattern recognition analysis for the quality evaluation of Cinnamomi Ramulus and Cinnamomi Cortex using HPLC/UV was developed. For quantitative analysis, three major bioactive compounds were determined. The separation conditions employed for HPLC/UV were optimized using an ODS $C_{18}$ column ($250{\times}4.6$ mm, 5 ${\mu}m$) with gradient conditions of acetonitrile and water as the mobile phase, at a flow rate of 1.0 mL/min and a detection wavelength of 265 nm. This method was fully validated with respect to linearity, accuracy, precision, recovery, and robustness. The HPLC/UV method was applied successfully to the quantification of three major compounds in the extract of Cinnamomi Ramulus and Cinnamomi Cortex. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of thirty eight Cinnamomi Ramulus and thirty five Cinnamomi Cortex samples. The results indicate that the established HPLC/UV method is suitable for quantitative analysis.
Extraction of quaternary ammonium compounds (choline and betaine) from plant samples (spinach) using ion exchange resin (AG1, OH− form) is a very simple and inexpensive approach. However, it is very hard to determine amounts of choline and betaine simultaneously using high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. Unlike choline, betaine has low molar absorptivity in UV-visible (UV-Vis) region, which makes it difficult to carry out UV-Vis detection of betaine. The mixture of quaternary ammonium compounds (choline and betaine) was derivatized using 2-bromo acetophenone as a derivatizing agent. As a result, choline did not react with the derivatizing agent, whereas betaine formed a betaine derivative. This betaine derivative exhibited detectable UV absorption with baseline separation between choline and the betaine derivative. Thus, with this method, choline and betaine can be determined simultaneously by using the HPLCUV method through one-step derivatization, which is an easy, sensitive, and reliable method.
In this study, polymer additives were extracted and separated by Soxhlet extraction method and the dissolution-precipitation method from a polycarbonate (optical grade) which completely absorbed UV light below 390 nm. Analytical techniques such as UV-Vis spectroscopy, FT-IR, and HPLC were applied to analyze additives in polycarbonate. Separated materials from the polycarbonate may be a complex mixture containing additives such as UV stabilizer, antioxidants (primary and secondary), monomers, and oligomers. Several compounds such as bisphenol A, Irganox 1010, and Cyasorb UV-5411 were identified by chromatograms and UV spectra obtained from RP HPLC analysis using Bondapak $C_{18}$ column, methanol mobile phase, and a photodiode array (PDA) detector. Also, the content of UV-5411 in the polycarbonate was about 0.12 wt% by a quantitative analysis through UV spectroscopy.
In this study, quantitative and pattern recognition analysis for the quality evaluation of Magnoliae Flos using HPLC/UV was developed. For quantitative analysis, eleven major bioactive lignan compounds were determined. The separation conditions employed for HPLC/UV were optimized using ODS $C_{18}$ column ($250{\times}4.6\;mm$, $5\;{\mu}m$) with isocratic elution of acetonitrile and water with 1% acetic acid as the mobile phase at a flow rate of 1.0 mL/min and a detection wavelength of 278 nm. These methods were fully validated with respect to the linearity, accuracy, precision, recovery, and robustness. The HPLC/UV method was applied successfully to the quantification of eleven major compounds in the extract of Magnoliae Flos. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of twenty one reference samples corresponding to seven different species of Magnoliae Flos and nine samples purchased from market. The results indicate that the established HPLC/UV method is suitable for the quantitative analysis and quality control of multi-components in Magnoliae Flos.
In this study, quantitative and pattern recognition analysis for the quality evaluation of Cimicifugae Rhizoma using HPLC/UV was developed. For quantitative analysis, three major bioactive phenolic compounds were determined. The separation conditions employed for HPLC/UV were optimized using ODS $C_{18}$ column ($250{\times}4.6mm$, $5{\mu}M$) with isocratic elution of acetonitrile and water with 0.1% phosphoric acid as the mobile phase at a flow rate of 1.0 mL/min and a detection wavelength of 323 nm. These methods were fully validated with respect to the linearity, accuracy, precision, recovery, and robustness. The HPLC/UV method was applied successfully to the quantification of three major compounds in the extract of Cimicifugae Rhizoma. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of twelve reference samples corresponding to five different species of Cimicifugae Rhizoma and seventeen samples purchased from markets. The results indicate that the established HPLC/UV method is suitable for the quantitative analysis and quality control of multi-components in Cimicifugae Rhizoma.
Ephedra alkaloids, (-)-ephedrine, (+)-pseudoephedrine, (-)-N-methylephedrine, (+)-N-methylpseudoephedrine, (-)-norephedrine and (+)-norpseudoephedrine, from ephedra herb are sympathomimetic agonists causing an increase of metabolism, blood pressure and perspiration. In this study, we developed the validation method of (+)-pseudoephedrine and (-)-ephedrine, two major ephedra alkaloids in Ephedra spp., by high-performance liquid chromatography-ultraviolet spectrometer (HPLC-UV). HPLC analysis was performed using a HECTOR-M C18 column operating at $35^{\circ}C$, and UV detection at 215nm. The mobile phase used a gradient flow with 25 mM SDS in water (A) and acetonitrile (B).
A simple HPLC-UV method was developed and validated for the quantification of human serum isepamicin using phenylisocyanate as a derivatization agent. The linear calibration curve was obtained in the concentration range of $1{\sim}100{\mu}g/ml$ and LLOQ of $1{\mu}g/ml$. This method was validated with selectivity, linearity, precision and accuracy, leading to successful application for estimating the pharmacokinetic parameters of isepamicin in Korean healthy subjects following IV infusion of 800 mg isepamicin. The mean $t_{1/2}$ of isepamicin was $1.55{\pm}0.08hr$.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.