• 제목/요약/키워드: HPLC-UV

검색결과 792건 처리시간 0.03초

Determination of Sesamin and Sesamolin in Sesame (Sesamum indicum L.) Seeds Using UV Spectrophotometer and HPLC

  • Kim, Kwan-Su;Lee, Jung-Ro;Lee, Joon-Seol
    • 한국작물학회지
    • /
    • 제51권1호
    • /
    • pp.95-100
    • /
    • 2006
  • Sesamin and sesamolin, antioxidant lipidsoluble lignan compounds, are abundant in sesame (Sesamum indicum L.) seed oil and provide oxidative stability of oil related to sesame quality. The sesamin and sesamolin contents of 403 sesame land races of Korea were determined by HPLC analysis of methanol extract (HPLC value), and their total lignan content was compared with those by using UV-Vis spectrophotometric analysis (UV method) of methanol (UV-MeOH value) and hexane (UV-Hexane value) extracts. HPLC values of total lignan content were strongly associated with UV-Hexane (r=0.705**) and UV-MeOH (r=0.811**) values. The UV values from both the extracts were 3.8-4.7 times higher than those of HPLC values. Lignan content was overestimated by UV method because total compounds in the mixture solution were quantified by absorbing at the same ultraviolet wavelength as in HPLC method. UV method could more rapidly analyze small amount of sample with higher sensitivity of detection than HPLC method. Average contents of lignans in sesame germplasm evaluated in this study were $2.09{\pm}1.02mg/g$ of sesamin, and $1.65{\pm}0.61mg/g$ of sesamolin, respectively, showing significant variation for lignan components. The results showed that UV method for the determination of sesamin and sesamolin could be practically used as a faster and easier method than HPLC by using the regression equations developed in this study.

산증류-HPLC법과 모니어윌리암스변법을 이용한 절임류중의 이산화황 함량 분석 (Determination of Sulfur Dioxide in Pickles by Acid Distillation-HPLC Method and Monnier Williams Modified Method)

  • 정소영;김일영;김성단;장미라;장민수;한기영
    • 한국식품과학회지
    • /
    • 제35권6호
    • /
    • pp.1028-1032
    • /
    • 2003
  • 절임류에 함유된 이산화황함량의 정확한 분석을 위해 산 증류후 HPLC-UV detector를 이용한 방법과 Monnier-Williams변법으로 실험해보았다. 산증류-HPLC-UV법은 절임류중의 아황산염을 산증류 시킨 후 발생하는 이산화황을 1% triethanolamine용액에 흡수시켜 이를 UV 240nm에서 정량하는 것으로서, 고정상은 음이온 교환컬럼을, 이동상으로는 1.8mM $Na_2Co_3$와 1.7mM $NaHCO_3$용액을 사용하였다. 이 방법으로 단무지에 아황산염을 첨가하여 실험 한 결과 $84.0{\sim}91.7%$의 회수율을 얻었다. 시중에 유통되는 48종의 절임류에 대해 모니어윌리암스변법과 산증류-HPLC-UV법을 이용하여 이산화황 함량을 조사해본 결과, 산증류-HPLC-UV법에 비해 모니어월리암스법에서 휘발성 산으로 인해 높은 농도를 나타내었다. 산증류-HPLC-UV법으로 분석한 절임류의 이산화황 농도는 불검출${\sim}173.05ppm$이었고, 기준인 30ppm을 초과하는 제품은 3건이었다.

Bromosulfophthalein의 체내동태 평가에 미치는 분석법의 영향: HPLC 법과 UV 흡광광도법의 비교 (Effect of Analytical Method on the Pharmacokinetic Evaluation of Bromosulfophthalein: Comparison of HPLC and UV Spectroscopy Method)

  • 오주희;차유경;이영주
    • Journal of Pharmaceutical Investigation
    • /
    • 제38권6호
    • /
    • pp.399-403
    • /
    • 2008
  • The aim of this study was to evaluate the difference of analytical methods for the pharmacokinetic study of bromosulfophthalein (BSP), an indicator of hepatobiliary function. The plasma and bile concentrations of BSP after intravenous administration were measured according to custom UV spectroscopy and HPLC, respectively. Plasma concentration of BSP measured by UV spectroscopy was similar to that measured by HPLC. There was no significant difference in the distribution volume, total body clearance, area under the curve and mean residence time of BSP between different analytical method groups. However, bile concentration of BSP measured by UV spectroscopy was overestimated compared with concentration measured by HPLC method. Biliary clearance of BSP obtained from UV spectroscopy method was almost 3 times higher than that obtained from HPLC method. Thus, a feasibility of UV spectroscopy method for high throughput pharmacokinetic evaluation of BSP was limited to the study based on the plasma concentration of BSP, not bile concentration.

HPLC 및 GC에 의한 농약분석에서 전처리에 대한 연구 (Studies on Pretreatment for Analysis of Pesticides by Using HPLC and GC)

  • 오보영;배준현;강준길;김연두
    • 대한화학회지
    • /
    • 제43권6호
    • /
    • pp.663-669
    • /
    • 1999
  • HPLC/UV 및 GC/FPD 법을 사용하여 환경수에 존재하는 Diazinon, EPN, Fenitrothion, Phosalon 및 Phosmet 등 5종의 유기인계 잔류농약을 분석하였다. 전처리 과정으로 고체상추출법(SPE)과 용매추출법(LLE)을 각각 적용한 결과, 회수율과 재현성에 있어, HPLC/UV에서는 용매추출법(LLE)보다 고체상추출법(SPE)이 더 우수하였고, GC/FPD에서는 고체상추출법(SPE)보다 용매추출법(LLE)이 더 우수하였다. 또 수돗물 및 하천수(와룡천)에 일정량의 유기인계 농약을 가하여 만든 합성시료중 각 성분을 분석한 결과, SPE-HPLC/UV 법에서는 회수율이 101%, % RSD는 4.3∼8.7이었고, LLE-GC/FPD 법에서는 회수율이 100%, % RSD는 3.2∼9.5이었다. 이 결과는 두 방법 모두 유기인계 잔류농약 분석에 이용할 수 있는 우수한 방법임을 제시하고 있다.

  • PDF

고속액체크로마토그래피에 의한 밀전분 지방질에 함유된 리소레시친의 정량 (Quantitative Analysis of Lysophosphatidyl Choline (LPC) in Wheat Starch Lipids by High Performance Liquid Chromatography)

  • 신명곤;민봉기;장판식
    • 분석과학
    • /
    • 제5권3호
    • /
    • pp.339-343
    • /
    • 1992
  • HPLC-UV방법을 이용하여 밀전분 지방질의 주성분인 LPC를 정량하기 위해 HRW 밀전분 지방질로부터 순수한 LPC를 분리하여 LPC의 표준곡선을 작성하였다. 밀 품종별 LPC에서 대한 HPLC peak responses는 시료간 큰 차이를 보여주지 않아 HRW 밀전분 지방질로부터 만든 LPC의 HPLC-UV 표준곡선은 밀전분 지방질에 함유되어 있는 LPC의 함량을 신속하고 정확하게 정량하는 데 이용할 수 있음을 보여 주었다.

  • PDF

폴리카보네이트에 사용된 첨가제의 분석 (Analyses of Additives Applied in a Polycarbonate)

  • 김석준
    • 분석과학
    • /
    • 제13권3호
    • /
    • pp.282-290
    • /
    • 2000
  • 본 연구는 390nm 이하에서 자외선 흡수가 완벽한 폴리카보네이트(광학용)에 첨가된 각종 첨가제를 아세톤으로 추출하거나 용해-침전 방식으로 분리하여 분석하는 것이다. 분리된 첨가제를 정성적으로 분석하기 위해 자외선흡광광도계, FT-IR 및 HPLC로 분석하였다. 분리된 물질은 광안정제 및 산화방지제(1차 및 2차)등의 첨가제와 단량체 및 올리고머가 함유된 복잡한 혼합물로 추정할 수 있다. 분리된 첨가물을 Bondapak $C_{18}$ 칼럼, 메탄올 이동상, PDA (Photodiode Array) 검출기를 사용한 역상(reversed phase, RP) HPLC 분석을 통해 비스페놀 A, Irganox 1010, Cyasorb UV-5411 성분들을 확인할 수 있있다. 또한, 자외선 흡광도를 이용한 정량분석을 통해 폴리카보네이트에 광안정제인 Cyasorb UV-5411가 0.12중량% 함유된 것을 알 수 있었다.

  • PDF

HPLC-UV검출방법으로 유도체화를 통한 비테인과 콜린의 동시분석 (Simultaneous determination of betaine and choline using derivatization by HPLC with UV detection)

  • 이인숙;팽기정
    • 분석과학
    • /
    • 제28권2호
    • /
    • pp.112-116
    • /
    • 2015
  • Extraction of quaternary ammonium compounds (choline and betaine) from plant samples (spinach) using ion exchange resin (AG1, OH form) is a very simple and inexpensive approach. However, it is very hard to determine amounts of choline and betaine simultaneously using high-performance liquid chromatography-ultraviolet (HPLC-UV) detection. Unlike choline, betaine has low molar absorptivity in UV-visible (UV-Vis) region, which makes it difficult to carry out UV-Vis detection of betaine. The mixture of quaternary ammonium compounds (choline and betaine) was derivatized using 2-bromo acetophenone as a derivatizing agent. As a result, choline did not react with the derivatizing agent, whereas betaine formed a betaine derivative. This betaine derivative exhibited detectable UV absorption with baseline separation between choline and the betaine derivative. Thus, with this method, choline and betaine can be determined simultaneously by using the HPLCUV method through one-step derivatization, which is an easy, sensitive, and reliable method.

Quantitative Analysis of Bioactive Marker Compounds from Cinnamomi Ramulus and Cinnamomi Cortex by HPLC-UV

  • Jeong, Su Yang;Zhao, Bing Tian;Moon, Dong Cheul;Kang, Jong Seong;Lee, Je Hyun;Min, Byung Sun;Son, Jong Keun;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • 제19권1호
    • /
    • pp.28-35
    • /
    • 2013
  • In this study, quantitative and pattern recognition analysis for the quality evaluation of Cinnamomi Ramulus and Cinnamomi Cortex using HPLC/UV was developed. For quantitative analysis, three major bioactive compounds were determined. The separation conditions employed for HPLC/UV were optimized using an ODS $C_{18}$ column ($250{\times}4.6$ mm, 5 ${\mu}m$) with gradient conditions of acetonitrile and water as the mobile phase, at a flow rate of 1.0 mL/min and a detection wavelength of 265 nm. This method was fully validated with respect to linearity, accuracy, precision, recovery, and robustness. The HPLC/UV method was applied successfully to the quantification of three major compounds in the extract of Cinnamomi Ramulus and Cinnamomi Cortex. The HPLC analytical method for pattern recognition analysis was validated by repeated analysis of thirty eight Cinnamomi Ramulus and thirty five Cinnamomi Cortex samples. The results indicate that the established HPLC/UV method is suitable for quantitative analysis.

HPLC-FLD와 MSD를 이용한 지하수 중 나프탈렌 및 TNT의 미량 분석법 개발 (Development of Analytical Methods for Micro Levels of Naphthalene and TNT in Groundwater by HPLC-FLD and MSD)

  • 박종성;오재일;정상조;최윤대;허남국
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권6호
    • /
    • pp.35-44
    • /
    • 2009
  • 나프탈렌과 TNT는 미국 환경청(U.S. EPA)에서 규정한 발암가능성 물질로(Group C), 환경으로 방출될 경우 수생태계와 인체에 심각한 영향을 주는 것으로 알려져 있다. 그러나 지하수 내 두 물질의 미량 분석법에 대한 기존연구는 매우 미비한 실정이다. 이에 본 연구에서는 HPLC-FLD(Fluorescence etector)와 MSD(Mass detector)를 이용한 지하수 내 나프탈렌 및 TNT의 미량분석법을 개발하여, MDL과 LOQ 및 이온영향을 조사하고, 현재 사용되고 있는 HPLC-UV 분석법과 비교 평가하였다. 나프탈렌의 경우, 3D-Fluorescence를 통하여 확인된 최고의 파장(Ex: 270 nM, Em: 330 nM)이 HPLC-FLD에 적용되었고, $0.3\;{\mu}g/L$의 MDL과 $2.0\;{\mu}g/L$의 LOQ가 획득되었다. 이는 현재 방법(HPLC-UV; MDL: $23.3\;{\mu}g/L$, LOQ: $163.1\;{\mu}g/L$)보다 약 80배 우수한 결과이며, U.S. EPA의 음용수 권고기준($700\;{\mu}g/L$)의 약 350배 이하까지 정량분석이 가능한 수치이다. TNT의 경우, 새롭게 제시된 HPLC-MSD로 측정한 방법(MDL: $0.13\;{\mu}g/L$, LOQ: $0.88\;{\mu}g/L$)이 HPLC-UV(MDL: $16.8\;{\mu}g/L$, LOQ: $117.5\;{\mu}g/L$ at 230 nM)보다 약 130 배 우수한 것으로 조사되었고, U.S. EPA의 음용수 권고기준($20\;{\mu}g/L$)보다 약 23배 낮은 농도까지 정량분석이 가능한 것을 확인하였다. 또한 HPLC-UV(230 nM)의 분석법은 ${NO_3}^-$ 농도가 증가할수록(특히 21 mg/L 이상) 크로마토그램의 기준선이 증가하여 정량에 방해를 주었으나, HPLC-MSD 분석법은 국내 지하수 평균 농도보다 약 3.5배인 63.7 mg/L에서도 분석의 영향 없이 안정한 크로마토그램을 보여주었다. 따라서 새롭게 제시된 HPLC-FLD와 MSD에의한 나프탈렌과 TNT 분석법은 지하수 및 음용수 미량분석에 적합하며, 관련분야 연구에 크게 도움이 될 것이다.

HPLC-UV를 이용한 중마황의 (+)-Pseudoephedrine과 (-)-Ephedrine의 동시분석법 개발 (Simultaneous Determination of (+)-Pseudoephedrine and (-)-Ephedrine in Ephedra intermedia by HPLC-UV)

  • 정비랑;윤유식;신순식;권용수;양희정
    • 생약학회지
    • /
    • 제48권1호
    • /
    • pp.93-96
    • /
    • 2017
  • Ephedra alkaloids, (-)-ephedrine, (+)-pseudoephedrine, (-)-N-methylephedrine, (+)-N-methylpseudoephedrine, (-)-norephedrine and (+)-norpseudoephedrine, from ephedra herb are sympathomimetic agonists causing an increase of metabolism, blood pressure and perspiration. In this study, we developed the validation method of (+)-pseudoephedrine and (-)-ephedrine, two major ephedra alkaloids in Ephedra spp., by high-performance liquid chromatography-ultraviolet spectrometer (HPLC-UV). HPLC analysis was performed using a HECTOR-M C18 column operating at $35^{\circ}C$, and UV detection at 215nm. The mobile phase used a gradient flow with 25 mM SDS in water (A) and acetonitrile (B).