• Title/Summary/Keyword: HPLC-PDA method

Search Result 90, Processing Time 0.032 seconds

Quantitative Determination of Compounds from Akebia quinata by High-Performance Liquid Chromatography

  • Yen, Nguyen Thi;Thu, Nguyen Van;Zhao, Bing Tian;Lee, Jae Hyun;Kim, Jeong Ah;Son, Jong Keun;Choi, Jae Sui;Woo, Eun Rhan;Woo, Mi Hee;Min, Byung Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.7
    • /
    • pp.1956-1964
    • /
    • 2014
  • To provide the scientific corroboration of the traditional uses of Akebia quinata (Thunb.) Decne., a detailed analytical examination of A. quinata stems was carried out using a reversed-phase high performance liquid chromatography (RP-HPLC) method coupled to photodiode array detector (PDA) for the simultaneous determination of four phenolic substances; cuneataside D (1), 2-(3,4-dihydroxyphenyl)ethyl-O-${\beta}$-D-glucopyranoside (2), 3-caffeoylquinic acid (3) and calceolarioside B (4). Particular attention was focused on the main compound, 3-caffeoylquinic acid (3), which has a range of biological functions. In addition, 2-(3,4-dihydroxyphenyl)ethyl-O-${\beta}$-D-glucopyranoside (2) was considered as a discernible marker of A. quinata from its easy confuse plants. The contents of compounds 2 and 3 ranged from 0.72 to 2.68 mg/g and from 1.66 to 5.64 mg/g, respectively. The validation data indicated that this HPLC/PDA assay was used successfully to quantify the four phenolic compounds in A. quinata from different locations using relatively simple conditions and procedures. The pattern-recognition analysis data from 53 samples classified them into two groups, allowing discrimination between A. quinata and comparable herbs. The results suggest that the established HPLC/PDA method is suitable for quantitation and pattern-recognition analyses for a quality evaluation of this medicinal herb.

Development of simultaneous determination of vitamin A and E in infant formula by micro-HPLC (Micro-HPLC를 이용한 조제분유 중 비타민 A.E 동시분석법 개발)

  • Yun I-Ran;Choi You-Jeong;Lee Min-Kwon;Jeong Myeong-Ho;Kim Byeong-Hun
    • Korean Journal of Veterinary Service
    • /
    • v.29 no.3
    • /
    • pp.339-346
    • /
    • 2006
  • Semi-micro-HPLC using a column-switching technique was developed for simultaneous determination of vitamin A and E contents in infant formula. Vitamin A and E were extracted by PDA - HPLC with reversed phase column using organic solvent and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with hydrolysis method and rapid extraction. Developed method has many advantages of simple and rapid sample preparation and simultaneous determination of vitamin A and E by micro-HPLC using reversed phase column.

Determination of eugenol in Eugenia caryophyllata by high-performance Liquid chromatography with photodiode array detection and method validation (HPLC-PDA를 이용한 정향(Eugenia caryophyllata) 중의 eugenol 분석법 확립 및 검증)

  • Yun, Hyeong-Jun;Yun, So-Mi;Lee, Myoung-Heon;Son, Seong-Wan
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • A method for the quantification of eugenol in the medicinal herb Clove was developed and validated. For preparation of sample solutions clove was dried at $60^{\circ}C$ for 2h and ground by mixer and extracted with 95% ethanol for shaking extraction. The elutes were analyzed by HPLC system included a reversed phase column, a isocratic mobile phase of 60% methanol and PDA detector set at 280 nm. Calibration graphs were linear with very good correlation coefficients ($r^2>0.9999$) from $0.0125~1{\mu}g/ml$. The limit of detection per sample injection ($20{\mu}l$) was $0.81ng/{\mu}l$ and limit of quantification was $2.47ng/{\mu}l$. The method showed good intra-day precision (%RSD 0.08 ~ 0.27%) and inter-day precision (%RSD 0.32 ~ 1.19%).

Optimization of Extraction Conditions for Swertiamarin in Swertia japonica Makino (당약의 swertiamarin 분석을 위한 추출조건 최적화)

  • Kim, Tae Hee;Jang, Seol;Lee, Ah Reum;Lee, A Young;Choi, Goya;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.29 no.1
    • /
    • pp.13-18
    • /
    • 2014
  • Objectives : Iridoid glycoside, swertiamarin is a well known bioactive component found in Swertia japonica Makino (SJ). In this study, we tried to optimize a suitable method which would extract swertiamarin effectively. Methods : Extraction of SJ was carried out by various conditions of time (5 - 60 min), temperature ($30-70^{\circ}C$), solvent (from non-polar to polar), and ratio of solvnet / sample (10 : 1 - 40 : 1) using ultrasonic extractor. Swertiamarin in SJ extracts was quantified by high performance liquid chromatography - Phtodiode array detector (HPLC-PDA) using C18 column and the analytical procedure was validated by evaluation of specificity, range, linearity, accuracy (recovery), precision (intra- and inter day variability), limit of detection (LOD), and limit of quantification (LOQ). Results : An efficient extraction condition for swertiamarin in SJ was optimized using sonicator extraction (temperature $40^{\circ}C$, solvent 20% methanol, solvent / sample (20 : 1), and time 10 min. Analytical procedure was optimized by HPLC-PDA using isocratic solvent system of acetonitrile and water (9 : 91), and the method was validated in regard to linearity (correlation coefficient, $R^2$ > 0.9999), range ($50-1000{\mu}g/mL$), intra- and inter-precision (RSD < 5.0 %), and recovery (99 -103 %). LOD and LOQ were 0.051 and $0.155{\mu}g/mL$, respectively. Conclusion : An optimized method of extraction for swertiamarin in SJ was established through conditions of diverse extraction and the validation result indicated that the method is suited for the determination of swertiamarin in SJ.

Study on the Marker Steroids of New Zealand Deer (Cervus elaphus var. scoticus) Velvet Antler by UPLC-MS/MS and HPLC-PDA Methods - (II)

  • Lee, Nam Kyung;Jang, Kyoung Hwa;Lee, Jong Tae;Park, Hee Won;Han, Sung Tai;In, Gyo
    • Natural Product Sciences
    • /
    • v.25 no.1
    • /
    • pp.49-58
    • /
    • 2019
  • Eleven steroid hormones (SHs: androstene-3,17-dione, estrone, ${\beta}$-estradiol, ${\alpha}$-estradiol, testosterone, dehydroepiandrosterone, $17{\acute{a}}$-hydroxyprogesterone, medroxyprogesterone, megestrol acetate, progesterone, and androsterone) were detected from New Zealand deer (Cervus elaphus var. scoticus) velvet antler (NZA, 鹿茸 ). A method for the quantification of eleven SHs was established by using ultraperformance liquid chromatography (UPLC)-MS/MS. The linearities ($R^2$ > 0.991), limits of quantification (LOQ values, 0.3 ng/mL to 23.1 ng/mL), intraday and interday precisions (relative standard deviation: RSD < 2.43%), and recovery rates (97.3% to 104.6%) for all eleven SHs were determined. In addition, a method for the quantification of three 7-oxycholesterols (7-O-CSs: 7-ketocholesterol, $7{\alpha}$-hydroxycholesterol, and $7{\beta}$-hydroxycholesterol) in the NZA was established by using an HPLC-photodiode array (PDA) method. The linearities ($R^2$ > 0.999), LOQ values (30 ng/mL to 350 ng/mL), intraday and interday precisions (RSD < 1.93%), and recovery rates (97.2% to 103.5%) for the three 7-O-CSs were determined. These quantitative methods are accurate, precise, and reproducible. As a result, it is suggested that the five steroid compounds of androstene-3,17-dione, androsterone, 7-ketocholesterol, $7{\alpha}$-hydroxycholesterol, and $7{\beta}$-hydroxycholesterol could be marker steroids of NZA. These methods can be applied to quantify or standardize the marker steroids present in NZA.

Discrimination between steam processed and unprocessed Tubers of Gastrodia elata Blume by HPLC

  • Zhao, Bing Tian;Song, Si Whan;Le, Duc Dat;Ma, Eun Sook;Son, Jong Keun;Woo, Mi Hee
    • Analytical Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.217-224
    • /
    • 2019
  • In this study, to evaluate the effectiveness and safety of oral therapy using Gastrodiae Rhizoma, a new HPLC-PDA analysis method was developed for the simultaneous quantitation of the three major components: (1) gastrodin, (2) gastrodigenin, and (3) p-hydroxybenzaldehyde, in steam processed and unprocessed tubers of Gastrodia elata Blume. The clear separation of the three components was achieved on a C18 column (250 × 4.6 mm, 5 ㎛) by gradient elution using water (including 0.1 % formic acid) and acetonitrile as the mobile phase. The flow rate was 1.0 mL/min, and the UV detector wavelength was set at 270 nm. The results demonstrate satisfactory linearity, recovery, precision, accuracy, stability, and robustness. The established HPLC-PDA method was applied to quantify three major compounds in 59 samples of G. elata Blume tubers. Finally, the steam processed and unprocessed tubers of G. elata Blume were successfully distinguished by pattern recognition analysis.

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

The Quantitative HPLC-PDA Method for Recombinant Interferon Alpha Analysis (유전자재조합 인터페론 알파의 HPLC-PDA에 의한 함량분석)

  • Kim, Gi-Hyun;Park, Ji-Eun;Paek, Seung-Kwan;Kim, Choon-Mi;Hong, Seung-Hwa;Lee, Hwa-Joung;Sohn, Yeo-Won
    • YAKHAK HOEJI
    • /
    • v.53 no.3
    • /
    • pp.101-106
    • /
    • 2009
  • Recombinant interferon alpha-2a is an active formula for the treatment of various cancer cells like malignant melanoma and a variety of virus infection diseases like acute or chronic hepatitis. The bioassay system based on the measurement of virus inhibitory activity by interferon has been used for interferon analysis with low repeatability. Here, we developed the HPLC assay to measure reproducibly interferon alpha-2a protein content which is replaceable to the reported bioassay. This method separated interferon alpha-2a from its oxidized forms and human serum albumin used as excipients. The regression coefficient using interferon alpha-2a EP CRS is more than 0.9 in the range from 5 ${\mu}g/ml$ to 200 ${\mu}g/ml$. The recovery result in the range from 15 ${\mu}g/ml$ to 60 ${\mu}g/ml$ is $97{\sim}104%$ and the precision is $0.2{\sim}1.7%$. The interferon alpha contents of 5 products are about 30 ${\mu}g/ml$.

Evaluation of the Immune-Stimulating Activity of Samul-tang, a Traditional Korean Herbal Medicine, Standardized by HPLC-PDA

  • Seo, Chang-Seob;Ha, Hye-Kyung;Jung, Da-Young;Lee, Ho-Young;Shin, Hyeun-Kyoo
    • The Journal of Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.25-34
    • /
    • 2011
  • Objectives: We performed simultaneous determination of five constituents by HPLC in Samul-tang (SMT). Additionally, we investigated the immune-stimulatory potential of SMT on specific cellular and humoral immune responses in ovalbumin (OVA)-immunized mice. Methods: Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array (PDA) detection at 190-400 nm, were used for quantification of the five components of SMT. Mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. C57BL/6 mice were immunized intraperitoneally with OVA/alum ($100{\mu}g/200{\mu}g$) on days 1, 8, and 15. The extract of SMT (1000 mg/kg) was given to mice orally for 21 days (from day 1 to day 21). At day 22, OVA-, lipopolysaccharide (LPS)- and concanavalin A (Con A)-stimulated splenocyte proliferation and OVA-specific and total antibodies were measured in plasma. Results: Calibration curves were acquired with $r^2$>0.9999, and the relative standard deviation (RSD, %) for intra- and inter-day precision were both less than 3.5%. The recovery was in the range of 95.69-115.12%, with an RSD less than 6.0%. The contents of five components in SMT were 1.08-15.30 mg/g. SMT significantly enhanced Con A-induced splenocyte proliferation in OVA-immunized mice (p<0.01). Also, SMT significantly enhanced OVAspecific IgG, IgG1 and total IgM levels in plasma compared with the OVA-immunized group. Conclusions: The established method will be applied for the quantification of major components and immunestimulating activity in OVA-immunized mouse model of SMT.