• Title/Summary/Keyword: HPLC method development

Search Result 363, Processing Time 0.023 seconds

Validation Process of HPLC Assay Methods of Drugs in Biological Samples (생체시료내 약물의 HPLC 분석법에 대한 유효성 검토방법)

  • Chi, Sang-Cheol;Jun, H.-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.3
    • /
    • pp.179-188
    • /
    • 1991
  • An HPLC assay method of a drug to be applied to the pharmacokinetic studies of the drug should be completely validated. The validation process for an HPLC assay method in a biological sample was discussed using the data obtained from the development of HPLC method for the simultaneous quantitation of verapamil and norverapamil in human serum. The validation criteria included were specificity, linearity, accuracy, precision, sensitivity, recovery, drug stability, and ruggedness of an assay method.

  • PDF

Validation of Precolumn HPLC Oxidation Method for Analysis of Paralytic Shellfish Poison (마비성패류독소 분석을 위한 Precolumn HPLC Oxidation 법의 유효성 검증)

  • Mok, Jong-Soo;Song, Ki-Cheol;Lee, Ka-Jeong;Kim, Ji-Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.46 no.2
    • /
    • pp.147-153
    • /
    • 2013
  • To prevent paralytic shellfish poisoning (PSP) due to the consumption of shellfish contaminated with PSP toxins, the quantitative analysis of these toxins is very crucial. The AOAC International mouse bioassay (MBA) has been used widely for the routine monitoring of PSP toxins for more than 50 years. However, this method has low sensitivity and high limit of quantification (LOQ) and interferences from other components in the extract, and it cannot determine toxic profiles. Ethical problems also exist with the continued use of this live mouse assay. To establish an alternative method to the MBA used for PSP toxins analysis, we attempted to optimize the analysis conditions of a precolumn high-performance liquid chromatography (HPLC) oxidation method and succeeded in validating its accuracy and precision in quantifying PSP toxins. A clear peak and the isolation of PSP toxins were obtained by injecting the working standards of Certified Reference Materials using HPLC. The LOQ of the precolumn HPLC oxidation method for PSP toxins was about $0.1002{\mu}g/g$, which represented an approximately fourfold improvement in detection capability versus the AOAC MBA. The intra-accuracy and precision for PSP toxins in oysters were 77.0-103.3% and 2.0-5.7%, respectively, while the respective inter-accuracy and precision were 77.3-100.7% and 2.4-6.0%. The mean recoveries of PSP toxins from oysters were 75.2-112.1%. The results of a comparison study showed good correlation between the results of the precolumn HPLC oxidation method and those of MBA, with a correlation factor of 0.9291 for mussels. The precolumn HPLC oxidation method may be used as an alternative to, or supplementary method with, MBA to monitor the occurrence of PSP toxins and to analyze the profiles of these toxins in shellfish.

Quantitative Analysis of Pyridostigmine Bromide in Tablets by HPLC (피리도스티그민 정제의 함량 측정을 위한 HPLC 분석법)

  • Phi, Taek-San;Cho, Young;Sok, Dae-Eun;Cha, Seung-Hee;Chung, Yun-Su
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.3
    • /
    • pp.171-177
    • /
    • 1991
  • A reverse-phase, ion-pair high performance liquid chromatographic (HPLC) method for the simultaneous quantative determination of pyridostigmine and its hydrolytic product, 3-hydroxy-N-methylpyridinium (HMP), is descrihed, The assay of pyridostigmine and HMP was linear in the range of amount from 24 to 60 mg/tablet and from 2.4 to 12.0 mg/tablet, respectively, with coefficient of variation (C.V.) of 0.05-0.12% (n=7) and 0.25-0.52% (n=5), respectively, and applicable conveniently even in the case of the mixture of pyridostigmine and HMP. Meanwhile, the conventional UV method gave inaccurate results for the aged pyridostigmine tablets. In the extraction of pyridostigmine from tablets prior to be assayed by HPLC, methanol was found to be more effective than ethanol or distilled water. Multiple extraction (four times) with methanol resulted in the full recovery of pyridostigmine, whereas ethanol gave 95% recovery even after four times extraction. Based on these results. the present method would be very useful for the accurate determination of pyridostigmine in the aged pyridostigmine tablets.

  • PDF

Simultaneous Determination of Vitamin A and E in Infant Formula by Rapid Extraction and HPLC with Photodiode Array Detection (신속추출법 및 PDA-HPLC에 의한 조제분유 중 비타민 A, E의 동시분석)

  • Kwak, Byung-Man;Lee, Ki-Woong;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.189-195
    • /
    • 2004
  • Rapid and simple method was developed for simultaneous determination of vitamins A and E contents in infant formula. Vitamins A and E were extracted by PDA-HPLC with reversed phase column using organic solvent, and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with results of Food Standards Codex and AOAC method for evaluation of developed method, Vitamins A and E contents in CRM determined by developed method were within certified range of standard values. Developed method has great advantages of simple and rapid sample preparation and simultaneous determination of vitamins A and E by PDA-HPLC using reversed phase column.

Development of Analytical Method and Validation using HPLC/PDA for Discrimination between Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba

  • Le, Duc Dat;Nguyen, Duc Hung;Zhao, Bing Tian;Min, Byung Sun;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.3
    • /
    • pp.275-283
    • /
    • 2019
  • In this study, we described the new developed method to simultaneously discriminate two herbal drugs of Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba using eight marker compounds (1 - 8) on an HPLC-PDA system. The developed method was applied to quantify the major components of two herbal drugs. The pattern analysis successfully discriminated and evaluated different components between Artemisiae Argyi Folium and Artemisiae Iwayomogii Herba. Results were used for classification of different species from collected samples.

Antioxidant Activity Analysis of Useful Compounds from Artemisiae Annuae Herba Using On-line Screening HPLC-ABTS+ Assay (On-line Screening HPLC-ABTS+ assay를 이용한 청호로부터 유용성분의 항산화 활성 분석)

  • Lee, Kwang Jin;Ma, Jin Yeul
    • Journal of Applied Biological Chemistry
    • /
    • v.57 no.4
    • /
    • pp.301-305
    • /
    • 2014
  • The Antioxidant activity screening identification of five kind compounds in Artemisiae annuae herba with the on-line screening high performance liquid chromatography (HPLC) $ABTS^+$ assay. The various experimental variables such as the extraction time (h) and extraction solvent composition (%) of dipping method were investigated efficiently extraction at the room temperature $25^{\circ}C$. The results, the highest yield of total extract amount (0.458 g, 15.250%) was obtained by dipping method with 100% water and extraction time to 3 h. And the on-line screening HPLC-$ABTS^+$ assay method was rapid and efficient to search for bioactivity from natural products.

Quantitation and Radical Scavenging Activity Evaluation of Iridoids and Phenylethanoids from the Roots of Phlomis umbrosa (Turcz.) using DPPH Free Radical and DPPH-HPLC Methods, and their Cytotoxicity

  • Le, Duc Dat;Nguyen, Duc Hung;Zhao, Bing Tian;Min, Byung Sun;Song, Si Whan;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • v.25 no.2
    • /
    • pp.122-129
    • /
    • 2019
  • The roots of Phlomis umbrosa (Turcz.) (Phlomidis Radix) have been traditionally used to treat cold, reduce swelling and staunch bleeding. Four iridoids (1 - 3 and 5) and six phenylethanoid derivatives (4, and 6 - 10) were isolated from the roots of P. umbrosa. A simple, sensitive, and reliable analytical HPLC/PDA method was developed, validated, and applied to determine 10 marker compounds in Phlomidis Radix. Furthermore, the isolates were evaluated for cytotoxic and anti-oxidant activities as well as DPPH-HPLC method. Among them, compounds 4 and 6 - 9 displayed potent anti-oxidant capacities using DPPH assay with $IC_{50}$ values of $27.7{\pm}2.4$, $10.2{\pm}1.1$, $18.0{\pm}0.8$, $19.1{\pm}0.3$, and $19.9{\pm}0.6{\mu}M$, and compounds 6, 8, and 9 displayed significant cytotoxic activity against HL-60 with $IC_{50}$ values of $35.4{\pm}3.1$, $18.6{\pm}2.0$, and $42.9{\pm}3.0{\mu}M$, respectively.

Analysis of Marker Substances in Samul-tang by HPLC-MS/MS (HPLC-MS/MS에 의한 사물탕의 지표성분 분석)

  • Yu, Young-Beob;Kim, Mi-Jung;Huang, Dae-Sun;Ha, Hye-Kyeong;Ma, Jin-Yeul;Shin, Hyeun-Kyoo
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • Objectives : This study presents a high performance liquid chromatography - electrospray ionization-mass spectrometer (HPLC-MS/MS) methods for the quantitative and qualitative analysis of various active components in Samul-tang, which is composed of four crude herbs. Methods : HPLC-ESI-MS/MS for the determinations of paeoniflorin and 5-HMF (5-hydroxymethyl 2-furaldehyde) in the Samul-tang, the separation method was performed on an COSMOS1L 5C18-AR-Il (2.0 X 150 mm I.D.) column by gradient elution with 0.1% acetic acid and 5% CH3CN in water (A)-0.1% acetic acid and 5% H20 in CH3CN (B) as the mobile phase at a flow-rate of 300 ${\mu}L/min$ with detection at quadrupole mass spectrometer. The all marker substances were always detected as the base peaks in the positive ion mode. Results : The paeoniflorin of Paeoniae Radix in Samul-tang showed a strong base peak [M+H2O]+ in the positive detection mode to give the following as; paeoniflorin (498.109 [M+H2O]+, 479.8 [M]+, 301 [M-glucose]+, 179.3 [glucose]+). Based on the HPLC retnetion time and MS of standard compounds confirmed the identity of active compounds in Rehmanniae Radix Preparata as follows; 5-HMF (127.0[M+H]+, 109.3 [M-OH]+) in the positive ion mode. Conclusion : According to the above results, HPLC-ESI-MS method permits assignment of tentative structures such as paeoniflorin and 5-HMF in the Samul-tang.

  • PDF

Validation of chlorophyll algorithm in Ulleung Basin, East/Japan Sea

  • Yoo, Sin-Jae;Kim, Hyun-Cheol;Lee, Jeong-ah;Park, Mi-Ok
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.1
    • /
    • pp.35-42
    • /
    • 2002
  • The results of our observation in May 2000 indicated that the SeaWiFS algorithm (O'Reilley et al., 1998), which was adopted for OSMI data processing, overestimated the actual chlorophyll values. This was rather unexpected in that there were good reasons to expect that the bio-optical properties of East/Japan Sea belonged to Case 1 water and in such case, the OC2 algorithm would give unbiased estimates of actual chlorophyll a values. In November 2000, a cruise conducted bio-optical surveys in the same area. This time we added HPLC (High Performance Liquid Chromatography) method for measuring chlorophyll a concentration to the standard fluorometric method, which we hale been using during the past Fluorometric method with acidification is known to result in under/overestimation of chlorophyll values in many parts of the world oceans, while it is easier and cheaper than HPLC method. To our surprise, the comparison of HPLC chlorophyll and fluorometric chlorophyll values show that fluorometric values gave an underestimation up to 50%. This error was due to the presence of accessory pigments such as chlorophyll b. Considering this error, our precious result of May 2000(Yoo et al., 2000) might have to be reinterpreted. Calculation of reflectance at 490 and 555nm, however, indicated that this is not still enough to explain the discrepancies.