• Title/Summary/Keyword: HEPA Filter

Search Result 54, Processing Time 0.026 seconds

Development and Performance Evaluation of Air-Supplied Mask (분진의 인체내 유입을 차단하기 위한 송기 마스크의 개발 및 성능평가)

  • Kim, Min Cheol;Kim, Hyun Tae;Lee, Kyoo Won
    • Clean Technology
    • /
    • v.4 no.1
    • /
    • pp.60-67
    • /
    • 1998
  • As workers' health and welfare are becoming increasingly important, there are needs for protecting workers from being exposed to dust particles in workplace. One of the simplest ways to protect workers is to wear a one-time-use mask of the 3M type. Although conventional masks are convenient to use, they provide low filtration efficiency simply because of air leaks through interface between the face and the mask. In this study, a new type of mask is developed and tested. The air which is filtered first using high efficiency particulate air(HEPA) filter is supplied to the nose area of workers' face. The developed mask was tested for filtration efficiency and for workers' acceptance. Very good results were obtained for both accounts.

  • PDF

Evaluation of Radioactive Stack Air Effluents from the Advanced Fuel Science Building at KAERI (한국원자력연구원 새빛연료과학동 굴뚝방출 방사능 평가)

  • Chang, S.Y.;Kim, B.H.
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Radioactivities of the stack air effluents from the Advance Fuel Science Building (AFSB) at KAERI have been investigated and evaluated. In this AFSB, nuclear fuels for the HANARO research reactor have been fabricated and the advanced nuclear fuels have been studied. A stack air monitoring system has been continuously operating to monitor the stack air effluents from the facility to protect the environment. As the results of the periodical radioactivity measurement and both the gamma and alpha spectrometry for the millipore filters taken from the stack air monitor from January until March 2008, a trace amount of primordial $^{40}K$ and the short-lived decay products of natural borne $^{222}Rn$ and $^{220}Rn$ have been detected. However, the radioactivities have rapidly decayed to the level below the Minimum Detectable Activity (MDA) of the counting system. Therefore, it was evaluated that no uranium isotopes have been released to the atmosphere from the stack of the AFSB at KAERI.

Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era (포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석)

  • Lee, Sejin;Lee, Wonseok;Kim, Eunseok;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.1
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통한 정전필터제조 및 특성분석)

  • Ahn, Young-Chull;Kim, Gil-Tae;Kim, Seong-Kon;Lee, Jae-Keun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1134-1138
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, electrical properties and filtration performance of electrospun filter media are quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. Electrospun filters show same collection efficiency with low pressure drop compare to commercialized HEPA filters. Surface charge potential and surface charge density of electrospun filters are increased with increasing applied voltage. Also collection efficiency of electrospun filters is increased with increasing surface charge potential and surface charge density.

  • PDF

Development of Antibacterial Hood and Filter for Medical Powered Air Purifying Respirators (PAPR) (의료용 전동공기청정호흡기(PAPR)용 항균성 후드 및 필터 개발)

  • Eunjoo Koh;Nahyun Cho;Yong Taek Lee
    • Membrane Journal
    • /
    • v.33 no.6
    • /
    • pp.398-408
    • /
    • 2023
  • This work developed a hood and filter for antibacterial protective clothing for medical powered air purifying respirators (PAPR) that can be used in medical settings and quarantine against infectious diseases such as Zika virus, Middle East respiratory syndrome (MERS), and coronavirus disease-19 (COVID-19). The hood material of the protective clothing was made of polypropylene spunlace nonwoven fabric (SFS) was used for withstand wind pressure and external physcial pressure. Forthermore, in order to reduce the user's risk of infection, phytoncide-based materials were used on the outer-surface of the hood to achieve a 99.9% antibacterial effect, and the inner-surface were treated with hydro-philic materials to improve absorbency by 25%. In addition to evaluating the artificial blood penetration resistance, dry mi-croorganism penetration resistance, wet bacteria penetration resistance, and bacteriophage penetration resistance required for medical protective clothing hoods, it received a passing evaluation of levels 2-6. Meanwhile, as a result of evaluating the performance of the antibacterial treated spunlace high efficiency particulate air (HEPA) filter, excellent antibacterial properties, dust removal rate, and differential pressure effect were confirmed. All performance evaluations were conducted by an accredited certification body in accordance with the medical PAPR certification standards.

Application of Cyclone to Removal of Hot Particulate in Hot Cell (Hot Cell 내의 고방사능 분진 제거를 위한 사이클론 적용 실험)

  • Kim Gye Nam;Lee Sung Yeol;Won Hui Jun;Jung Chong Hun;Oh Won Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.67-75
    • /
    • 2005
  • The size and main ingredient of hot particulate generated during the nuclide experiment in hot cells of nuclear facilities were 0.5300 $\mu$m and UO$\_2$. A cyclone filter equipment which consists of a cyclone and Bag/HEPA filter was devised to remove hot particulate generated during the nuclide experiment in hot cells of nuclear facilities. The experimental conditions to maximize the collection efficiency of hot particulate were suggested through experiments done with the cyclone filter equipment. With the large size of simulated particulate, the collection efficiency of the particulate was high. When the size of simulated particulate was more than 5 $\mu$m, the collection efficiency of the particulate was more than $80\%$ and when the size of simulated particulate was less than 1.0 urn, the collection efficiency decreased by less than $70\%$. If the inflow velocity of simulated particulate was increased, the collection efficiency of the particulate was also increased. When the inflow velocity of simulated particulate was more than 12m/sec, the collection efficiency was higher than $70\%$, but after 17 m/sec inflow velocity, no change observed. The collection efficiency of the simulated particulate can be enhanced with the length of vortex finder inside the chamber. With the length of vortex finder, 7.2cm, the observed collection efficiency of the particulate was the maximum. Moreover, when the sub-cone was attached under the cyclone, the collection efficiency of cyclone increased $2\%$. It was found that effect by attachment of sub-cone was not serious.

  • PDF

Control of Particle Contamination and Heat Build-Up for Noble Design of an Optical Disk Drive (광디스크 드라이브의 입자 오염 및 열축적 제어를 위한 설계 제안)

  • Oh, Seo-Young;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • Airborne contaminant particles are intruded into optical disk drives(ODD) due to the flow caused by disk rotation and can be adhered to lens or disk surfaces, which causes decrease of laser power and increase of read/write errors. Such a phenomenon can be more serious as the space between the disk and the lens is reduced fur high-density storage devices. The purpose of this paper is to understand design parameters to reduce the particle intrusion into an ODD. Suggestions are made to prevent the particle intrusion that can decrease the stability of an ODD and also prevent the potential heat build-up problem. The sealing effect of drive and the forced injection of clean air (using HEPA filter) into the drive minimizes intrusion of the outside air and dusts in an ODD remarkably. Moreover it is proved by experiments that the installation of a heatproof pad to isolate heat generation part (PCB) from information read/write sections and the forced injection of dust-free air reduce the gas temperature inside the drive as well as the amount of particles intruded.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

Development of the Air Floating Conveyor System for the Large Glass Sheet (대평판 글라스 이송용 공기 부상 이송장치의 개발)

  • Lee, Tae Geol;Yu, Jin Sik;Jung, Hyo Jae;Kim, Jong-Hyeong;Kim, Joon Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.635-642
    • /
    • 2013
  • We have prepared a DEMO conveyor device for conveying a large 8G class glass sheet using ahorizontal air-cushion system. This device consists of the body frame and the driving frame that are combined to realize a frame for conveying glass without any contact.The driving frame comprises an air flotation table (bed), drive roller supported at both ends, and ASU. Part of the ASU serves to control the airflow as the chamber consists of a porous pad and fan. Fiber filters replace the porous pad and axial fans serve as an air compressor. In addition, to determine the appropriate glass levitation from the air table, this study examined the design specifications of the applied filter (discharge speed of HEPA and ULPA filters, and flow rate) as well as the height of the and the proper supporting roller height (14mm). Then, after adjusting the position of the ASU and the number of ASUs required to configure the UNIT air floating C/V, we analyzed the height and flatness of the glass and derived the appropriate layout (1140-mm distance between ASUs).

Assessment of hazardous substances and workenvironment for cleanrooms of microelectronic industry (전자산업 청정실의 작업환경 및 유해물질농도 평가)

  • Chung, Eun-Kyo;Park, Hyun-Hee;Shin, Jung-Ah;Jang, Jae-Kil
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.280-287
    • /
    • 2009
  • High-tech microelectronics industry is known as one of the most chemical-intensive industries. In Korea, Microelectronics industry occupied 38% of export and 16% of working employees work in microelectronics industry. But, chemical information and health hazards of high-tech microelectronics manufacturing are poorly understood because of rapid development and its penchant for secrecy. We need to investigate on chemical use and exposure control. We Site-visits to 6 high-tech microelectronics manufacturing company which have cleanroom work using over 1,000kg organic solvents (5 semi-conductor chips and its related parts company, 1 liquid crystal display (LCD)). We reviewed their data on chemical use and ventilation system, and measured TVOCs (Total Volatile Organic Compounds) and carbon dioxide concentration. All cleanroom air passed through hepa filters to acheive low particle levels and only 1 cleanroom uses carbon filters to minimize the organic solvents exposures In TVOC screening test, Cleanroom for semi-conductor chips and its related parts company with laminar down flow system (e.g. class 1~100) showed nondetectable level of TVOCs concentration, but Cleanroom for liquid crystal display (LCD) with conventional flow system (e.g. class 1,000~10,000) showed 327 ppm as TVOCs. Acetone concentration in cleanroom for Jig cleaning, LC Injection, Sealing processes were 18.488ppm (n=14), 49.762 ppm (n=15), 8.656 ppm (n=14) as arithmetric mean. Acetone concentration in cleanroom for LCD inspection process was 40ppm (n=55) as geometric mean, where the range was 7.8~128.7ppm and weakly correlated with ventilation rate efficiency(r=0.44, p<0.05). To control organic solvents in cleanrooms, chemical and carbon filters should be installed with hepa filters. Even though their volatile organic compounds concentration was not exceed to occupational exposure limits, considering of entrance limited cleanroom environment, long-term period exposure effects and adverse health effects of cleanroom worker need further reseach.