• Title/Summary/Keyword: HEATER

Search Result 1,746, Processing Time 0.029 seconds

Stress Analysis of Gas-Gas Heater in Thermal Power Plant (화력발전용 가스재열기의 응력 해석)

  • Hwang, Suk-Hwan;Choi, Jae-Seung;Lee, Hoo-Gwang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.1
    • /
    • pp.204-211
    • /
    • 2002
  • Today\`s industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization(FGD) system is installed in thermal power plant and gas-gas heater(GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas-gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design. And finite element analysis(FEA) for rotor part in GGH is performed with original model and two weight-reduced models with different diaphragm thickness, respectively. Stress concentrations at rotor diaphragm happen due to the dead weight, pressure difference between treated and untreated gas, and thermal distribution in the rotor. As the thickness of diaphragm is decreased, the stress level is increased. The direction of treated gas and untreated gas flow may affect the stress level.

Experimental Study on the Performance of a CO2 Heat Pump Water Heater under Various Operating Conditions (이산화탄소 급탕 열펌프의 운전조건에 따른 성능 특성에 관한 실험적 연구)

  • Sohn, Dong-Jin;Baek, Chang-Hyun;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.273-280
    • /
    • 2011
  • In this study, the steady state performance of a $CO_2$ heat pump water heater was measured with a variation of operating conditions such as refrigerant charge amount, compressor frequency, EEV opening, and water mass flow rate. Transient state performance tests were also conducted to investigate major system effects associated with the interaction between the $CO_2$ heat pump water heater and the water tank. Optimum refrigerant charge amount for the system was 1600 g. At compressor frequencies of 50 Hz and 60 Hz, water mass flow rates of 95 kg/h and 105 kg/h, and EEV opening of 8% and 16%, the water heating temperatures were $65^{\circ}C$ and $68^{\circ}C$ and COPs were 3.0 and 2.8, respectively. In the transient condition, the instantaneous COP decreased with an increase in the inlet water temperature.

Development of monitoring system for demonstration test of solar energy system (태양에너지 시스템의 실증시험을 위한 모니터링 시스템 개발)

  • Yang, Dong-Jo;Kim, Jae-Yeol;Oh, Yool-Kwon;Kim, Jin-Heung;Chung, Nak-Kyu;Cho, Guem-Bae
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.723-726
    • /
    • 2005
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

A Controller Development of Water Heating in a Ceramic Pipe Using Electronics Control System (전자제어 장치를 이용한 세라믹 파이프의 온수제어기 개발)

  • Lee, Jung-Suk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.717-722
    • /
    • 2011
  • This paper presents that the electronic controller is developed for controlling the setting temperature and water in the ceramic pipe system. The heating water system is designed for controlling the temperature to supply the heat through the ceramic pipe heater to input the water, also for controlling quantity of water using the water sensor and impeller. The control method of the heating water system is applied the mathematic modeling of the ceramic pipe heater on the suppling the heat at coming water, and the test result of the electronic controller is present to smartly control the setting temperature, therefore the ceramic pipe heater is proposed to be able to apply the heating structure and the control methods as a product.

Analysis of Contaminants in a $CH_4-O_2$ Vitiated Air Heater ($CH_4-O_2$ Vitiated 공기가열기에서의 오염도 분석)

  • Na, Jae-Jeong;Lee, Jung-Min;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.447-450
    • /
    • 2010
  • This study was conducted to explore the flow contamination in the $CH_4-O_2$ vitiated air heater. Non-equilibrium and equilibrium calculation were made of the flow processes in the heater and nozzle assuming the inviscid and one dimensional flow. The results were compared with the measurement data. The overall results of this study showed additional non-equilibrium calculation should be considered to assess the presence of NO, which species could yield the combustion delay or no reaction, as a contaminant.

  • PDF

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Kim, Sang-Nyung
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF

Performance Evaluation of a Defrosting System Using the Condensation Heat of a Refrigerator in Cold Storage (저온창고에서 냉동기 응축폐열을 이용한 제상시스템 성능평가)

  • Park, Chunwan;Lee, Donggyu;Im, Kwanbin;Kang, Chaedong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • In a cold chain, the refrigerator is also employed for defrosting, by using an electric heater, which consumes 15% of the power for the system operation. In this study, the condensation heat of the refrigerant was suggested as the heat source of defrosting heat, instead of that from an electric defrost heater. The heat for defrosting was stored to a phase change material (PCM, NMP : $52^{\circ}C$) in thermal storage, and was periodically supplied to the evaporator by a circulation loop of brine. As a result, a defrost time by the PCM was obtained that was less than or equal to that by the electric heater. Moreover, power consumption during defrosting was saved by up to 99% of that of the electric heater.

Temperature Property Analysis of Micro Flow Sensor using Thermal Transfer Equation (열운송 방정식을 이용한 마이크로 흐름센서의 온도특성 해석)

  • Kim, Tae-Yong;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.363-366
    • /
    • 2005
  • A micro flow sensor on silicon substrate allows the fabrication of small components where many different functions can be integrated so that the functionality of the sensors can be increased. Further more, due to the small size of the elements the sensors can be quite fast. A thermal mass flow sensor measures the asymmetry of temperature profile around the heater which is modulated by the fluid flow. In normal, a mass flow sensor is composed of a central heater and a pair of temperature sensing elements around the heater. A new 2-D wide range micro flow sensor structure with three pairs of temperature sensors and a central heater was proposed and numerically simulated by the Finite difference formulation to confirm the feasibility of the flow sensor structure.

  • PDF

The Study of the Fire Possibility of Sheath Heater without Safety Device in Use(Focused on the fire cases) (안전장치 없는 시즈히터에 대한 사용중 발화 가능성 연구(화재사례를 중심으로))

  • Mun, Yong-Su;Myeong, Jeong-Ho;Choe, Jin-Man;Kim, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.4 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The purpose of this study on the sheath heater having high occurrence of fires in a small work place because of not having the safety device, was to find out the characteristics required in the field examination of the fires in the courses of investigation. The results of the experiments conducted and reviewed on the basis of the fire cases whose conditions of the ignition possibility were divided into A, E, C and D are as follows: When the sheath heater without safety device is left on the condition of the heat accumulation of which the temperature rapidly rise, and then ignite the inflammables of the surroundings. In such cases, it was characterized that the color change trace appeared even if no short trace was discovered in the power line.

  • PDF

Fabrication of NO sensor integrated SiC micro heaters for harsh environments and its characteristics (SiC 마이크로 히터가 내장된 극한 환경용 NO 센서의 제작과 특성)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.197-201
    • /
    • 2010
  • This paper describes the fabrication and characteristics of a NO sensor using ZnO thin film integrated 3C-SiC micro heater based on polycrystalline 3C-SiC thin film of operation in harsh environments. The sensitivity, response time, and operating properties in high temperature and voltages of NO sensors based SiC MEMS are measured and analyzed. The sensitivity of device with pure ZnO thin film at the heater operating power of 13.5 mW ($300^{\circ}C$) is 0.875 in NO gas concentration of 0.046 ppm. In the case of Pt doping, the sensitivity of at power consumption of 5.9 mW ($250^{\circ}C$) was 1.92 at same gas flow rate. The ZnO with doped Pt was showed higher sensitivity, lower working temperature and faster adsorption characteristics to NO gas than pure ZnO thin film. The NO gas sensor integrated SiC micro heater is more strength than others in high voltage and temperature environments.