• Title/Summary/Keyword: HEARTRATE

Search Result 10, Processing Time 0.027 seconds

Psychological and Physiological Responses of Occupants Caused by Types of Seat Air Conditioning (좌석시트 공조조건에 따른 착석자의 심리 및 생리적 반응)

  • Kim, Boseong;Kwak, Seung Hyun;Seo, Sang Hyeok;Min, Byung Chan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.3
    • /
    • pp.14-20
    • /
    • 2015
  • It is important to understand psychological and physiological responses of occupants who seated in a chair in order to shape a comfortable indoor official environment. So it is needed to find out optimal seated conditions. The purpose of this study was to explore optimal condition of seat air conditioning control based on psychological or subjective responses (perceived temperature and comfort sensation) and physiological responses (heartrate variability; HRV). To do this, experimental conditions were designed by the difference of indoor temperature and seat air conditioning temperature. In the experiment 1, seven experimental conditions were designed with one control condition which was not used seat air conditioning system, and six experimental conditions which the difference of indoor temperature and seat air conditioning temperature ($-1^{\circ}C{\sim}-6^{\circ}C$). In the experiment 2, four experimental conditions were designed with one control condition and three experimental conditions ($-3^{\circ}C{\sim}-5^{\circ}C$). In addition, participants' psychological or subjective response was measured by CSV (comfort sensation vote) and PTS (perceived temperature sensitivity) as a psychological or subjective response, and heartrate variability was measured as a physiological response. As a result, in the experiment 1, it was reported that the optimal conditions of seat air conditioning control based on participants' psychological or subjective comfort were from $-3^{\circ}C$ to $-5^{\circ}C$ experimental conditions. In addition, in the experiment 2, it was reported that the optimal condition of seat air conditioning control based on participants' physiological comfort was $-4^{\circ}C$ experimental condition. These results suggested that seat air conditioning could affected to comfort sensation of occupants in an appropriate range, rather than unconditionally.

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.

Development of Mobile Healthcare System Using ECG Measurement (심전도 측정을 이용한 모바일 헬스케어 시스템 개발)

  • Kim, Seong-Woo;Shin, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2008-2016
    • /
    • 2014
  • With the increased attention about health care and management of heart diseases, ubiquitous healthcare services and related devices have been actively developed recently. In this paper we developed a mobile healthcare system which consists of smartphone and patch-type ECG measuring device. This system is capable of monitoring, storing, and sending bio signals such as ECG, heart rate, heart rate variability as well as exercise management functions through heart rate zones. With monitoring bio signal continuously by mobile healthcare system and wearable device like us, people can prevent chronic disease and maintain good health. Here we report our implementation results on real platforms.

The Impact of Fatigue on Hazard Recognition: An Objective Pilot Study

  • Ibrahim, Abdullahi;Okpala, Ifeanyi;Nnaji, Chukwuma;Namian, Mostafa;Koh, Amanda
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.450-457
    • /
    • 2022
  • The construction industry is demanding, dynamic, and complex making it difficult for workers to recognize hazards. The nature of construction tasks exposes workers to several critical risk factors, such as a high rate of exertion and fatigue. Recent studies suggest that fatigue may impact hazard recognition in the construction industry. However, most studies rely on subjective measures when assessing the relationship between physical fatigue and hazard recognition, limiting such studies' efficacy. Thus, this study examined the relationship between physical fatigue and hazard recognition using a controlled experiment. Worker fatigue levels were captured using physiological data and a subjective exertion scale. The findings confirmed that physical exertion plays a significant role in hazard recognition skills (p < 0.05). This research contributes to theory and practice by providing a process for objectively assessing the influence of physical fatigue on worker safety and providing construction professionals with some critical insight needed to improve workplace safety.

  • PDF

A Study on Exercise Physiology of Climbing in Step-trail -At Keumsan in Hallyo-Haesang National Park- (한려해상국립공원 계단형 등산로에서 등산의 운동생리학적 연구 - 금산지구를 중심으로 -)

  • 이준우;박범진;최윤호;김재수
    • Korean Journal of Environment and Ecology
    • /
    • v.12 no.4
    • /
    • pp.398-405
    • /
    • 1999
  • This study was carried out to investigate exercise load of visitors and physical condition of stairway in the trail of Keumsan located in Hallyo-Haesang National Park. Total trail length of Keumsan is 2,126m, and the number of step-trail section are 15, and the total length of step-trail section is 1,000.4m. Average gradient of step-trail was 20~40%. But the gradient and length were 45.7% and 268.5m in the section 11, and 58.4% and 188.6m in the section 12. The greatest gradient was 67.8% in the section 13. During the climbing in trail, heart rate were 104~184beats/min.. And in the step-trail section 11, 12, and 13, IHR, ELI, and %HRmax were 166.5%, 89.1%, 92.9%, and 167.4%, 89.6%, 93.2%, and 157.8%, 84.5%, 89.9%, respectively.

  • PDF

Spectral Analysis of Heart Rate Variability in ECG and Pulse-wave using autoregressive model (AR모델을 이용한 심전도와 맥파의 심박변동 스펙트럼 해석)

  • Kim NagHwan;Lee EunSil;Min HongKi;Lee EungHyuk;Hong SeungHong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • The analysis of power spectrum based on linear AR model is applied widely to quantize the response of autonomic nerve noninvasively, In this paper, we estimate the power spectrum density for heartrate variability of the electrocadiogram and pulse wave for short term data(less than two minute), The time series of heart rate variability is obtained from the time interval(RRI, PPI) between the feature point of the electrocadiogram and pulse wave for normal person, The generated time series reconstructed into new time series through polynomial interpolation to apply to the AR mode. The power spectrum density for AR model is calculated by Burg algorithm, After applying AR model, the power spectrum density for heart rate variability of the electrocadiogram and the pulse wave is shown smooth spectrum power at the region of low frequence and high frequence, and that the power spectrum density of electrocadiogram and pulse wave has similar form for same subject.

  • PDF

Analysis of the Optimal Location of Wearable Biosensor Arrays for Individual Combat System Considering Both Monitoring Accuracy and Operational Robustness (모니터링 정확도와 운용 강건성을 고려한 개인전투체계용 착용형 생체센서 어레이의 최적 위치 분석)

  • Ha, Seulki;Park, Sangheon;Lim, Hyeoncheol;Baek, Seung Ho;Kim, Do-Kyoung;Yoon, Sang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.287-297
    • /
    • 2019
  • Monitoring for the physiological state of a solider is essential to the realization of individual combat system. Despite all efforts over the last decades, there is no report to point out the optimal location of the wearable biosensors considering both monitoring accuracy and operational robustness. In response, we quantitatively measure body temperature and heartrate from 34 body parts using 2 kinds of biosensor arrays, each of which consists of a thermocouple(TC) sensor and either a photoplethysmography(PPG) sensor or an electrocardiography(ECG) sensor. The optimal location is determined by scoring each body part in terms of signal intensity, convenience in use, placement durability, and activity impedance. The measurement leads to finding the optimal location of wearable biosensor arrays. Thumb and chest are identified as best body parts for TC/PPG sensors and TC/ECG sensors, respectively. The findings will contribute to the successful development of individual combat system.

A Study on Energy Efficiency in Walking and Stair Climbing for Elderly Wearing Complex Muscle Support System

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung Cheol Shin;Hwang-Jae Lee;Wan-Hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.478-487
    • /
    • 2022
  • Objective: This study was conducted to analyze the effect of wearable complex muscle support system on energy efficiency during walking in elderly. Design: Cross sectional study Methods: Twenty healthy elderly participated in this study. All subjects performed a 6 minuteswalk test(6MWT) and stair climbing test in dual, slack and no suit conditions. In each condition, oxygen consumption(VO2), metabolic equivalents(METs), energy expenditure measures(EEm), physiological cost index(PCI), walking velocity and heartrate were measured. Through repeated measured ANOVA, it was investigated whether there was a statistically significant difference in the measurement results between the three conditions. Results: In over-ground walking, VO2, METs and EEm showed significant differences between no suit and slack conditions(p<0.05). In stair climbing, VO2 showed significant difference between slack and dual conditions(p<0.05). Also, METs and EEm showed significant differences between no suit and slack, and between slack and dual conditions(p<0.05). Conclusions: Wearing the wearable complex muscle support system for elderly does not have much benefit in energy metabolism efficiency in over-ground, but there is a benefit in stair walking.

Relationship between subjective and objective measures of anticipatory anxiety prior to extraction procedures in 8- to 12-year-old children

  • Kalra, Namita;Sabherwal, Puja;Tyagi, Rishi;Khatri, Amit;Srivastava, Shruti
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.2
    • /
    • pp.119-128
    • /
    • 2021
  • Background: This study assessed anticipatory dental anxiety levels among 8- to 12-year-old children based on subjective and physiological measures and their correlation. The variations in anxiety based on sex, age, temperament, and academic performance were evaluated. Methods: An observational study was conducted in 60 children recruited from the waiting room over a 6-month period. The operator recorded subjective anxiety in the children using a novel visual facial anxiety scale. The operator also noted the demographic details and child's temperament using the nine dimensions of the Thomas and Chess criteria, and graded children as "easy," "slow to warm-up," and "difficult." The academic performance of the children was graded (parental ratings) on a five-point Likert scale. Physiological variables (heartrate [HR], oxygen saturation[SpO2], and blood pressure [BP]) were recorded by another evaluator. The correlation between anxiety levels and physiological variables was also assessed. The effects of age, sex, temperament, and academic performance on anxiety were evaluated. Results: The study included 60 children aged 8-12 years, including 36 boys and 24 girls. Seventy percent of children had mild to moderate levels of pre-extraction anxiety, while 30% of children demonstrated high anxiety. A significant positive correlation was noted between anxiety levels and HR (rs = 0.477, P < 0.001⁎) and systolic BP (rs = 0.294, P < 0.05), while a significant but inverse correlation was observed with SpO2 (rs = -0.40, P < 0.05). Anxiety did not influence diastolic BP. Children with difficult temperament and poor academic performance had significantly higher anxiety. Conclusion: A high percentage (70%) of children aged 8-12 years had mild to moderate anxiety prior to the extraction procedure. Increased HR, systolic BP, and reduced SpO2 were significantly associated with high levels of anticipatory dental anxiety. Pre-extraction anxiety was significantly related to the temperament and scholastic performance.