• Title/Summary/Keyword: HEALTH

Search Result 98,715, Processing Time 0.107 seconds

A Study on Serum Lipid Levels of Children in Pusan (부산지역 일부 소아의 혈청 지질 분포에 관한 연구)

  • Kang, Soo-Yong;Cho, Byung-Mann;Lee, Su-Ill;Hwang, In-Kyong;Kim, Yeung-Wook;Kim, Young-Sil;Cha, Ae-Ri;Ha, I-Ho;Lee, Chel-Ho;Kim, Don-Kyoun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.686-696
    • /
    • 1997
  • This is a cross-sectional study to evaluate the serum lipid levels of children living in Pusan in 1996. The distribution of age is from 2 years old to 12 years old. In female children mean total cholesterol is $171.4{\pm}26.2mg/dl$, triglyceride is $104.7{\pm}50.6mg/dl$, HDL-cholesterol is $54.4{\pm}14.8mg/dl$, and LDL-cholesterol is $95.4{\pm}32.9mg/dl$. In male children mean total cholesterol is $167.9{\pm}25.2mg/dl$, triglyceride is $6{\pm}45.5mg/dl$, HDL-cholesterol is $55.4{\pm}11.7mg/dl$, and LDL-cholesterol is $94.4{\pm}23.6mg/dl$. The percentile of serum lipid levels is measured in children. The 95th percentile of serum total cholesterol is 210mg/d1 in male children, and 214mg/d1 in female children. And, the 95th percentile of serum triglyceride is 184mg/d1 in male children, and 191mg/d1 in female children. And, the 95th percentile of LDL-cholesterol is 133mg/d1 in male children, and 135mg/d1 in female children. Serum total cholesterol is positively .Elated to age(r=0.18), height(r=0.08), weight (r=0.17), obesity index(r=0.12), and negatively .elated to father's education level (r=-0.13), mother's education level(r=-0.13). Serum triglyceride is positively related to weight(r=0.23), age(r=0.31) and negatively .elated to father's education level(r=-0.12), mother's education level(r=-0.18). Serum HDL-C was positively reated to mother's education level(r=0.07) and negatively .elated to height(r=-0.12), weight(r=-0.09). Conclusively, the serum lipid levels of children living in Pusan is generally so high that the family and school must try to control the serum lipid levels.

  • PDF

$HgCl_2$ Dysregulates the Immune Response of Balb/c Mice (수은에 의한 마우스의 면역반응 조절장애)

  • Ki, No-Suk;Koh, Dai-Ha;Kim, Chong-Suh;Lee, Jung-Sang;Kim, Nam-Song;Lee, Hwang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.1 s.45
    • /
    • pp.11-24
    • /
    • 1994
  • The studies reported here were undertaken to investigate the effects of mercury chloride on immune system of Balb/c mouse employing a flexible tier of in vitro and in vivo assays. Mercury chloride inhibited the proliferative responses of spleen cells to lipopolysaccharide, pokeweed mitogen, and phytohemagglutinin as a dose-dependent manner. This inhibitory effect was observed not only when $HgCl_2$ was added 2nd or 3rd day of 3 days culture period but also when spleen cells was pretreated with $HgCl_2$ for 2 hours. Mercury chloride, however, potentiated the production of IgM and IgG from spleen cells. During the $HgCl_2$ administration by drinking for 3 weeks, the weight gain of mice was significantly blunted than that o control group mice, while no overt signs related to mercury toxicity were noted in any mice of experimental group. There was no change in thymus and spleen weights, and in histological findings of kidney, bone marrow of femur, thymus, spleen, and popliteal lymph node after 3 weeks of mercury exposure. However, $HgCl_2$ induced a significant increase of total serum IgM, IgG including $IgG_1,\;IgG_{2a}\;and\;IgG_{2b}$, and IgE in Balb/c mice. Treatment in vivo with anti-IL-4 monoclonal antibody significantly abrogated the $HgCl_2$-induced increase in total serum IgG1 and IgE. Whereas $HgCl_2$ potentiated total serum IgM and IgG, there was no difference in total serum hemagglutinin to SRBC (Sheep Red Blood Cell) between experimental and control group mice when these mice were immunized with SRBC. All these findings observed in Balb/c mice suggest that mercury perturbates well-orchestrated regulation of immune responses before developing histopathological changes in lymphoid tissues.

  • PDF

A Study on the Medical Insurance Utilization of Workers Suffering from Low Back Pain in an Area (일부지역 근로자의 요통으로 인한 의료보험 이용 조사)

  • Lee, Chul-Gab;Ahn, Hyun-Ok;Ryu, So-Yeon;Park, Jong;Kim, Ki-Soon;Kim, Yang-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.764-778
    • /
    • 1997
  • To find the medical insurance utilization of workers when suffering from low back pain, an analysis was made toward the data of medical insurance benefits matched with the general characteristics of 10,183 workers, who were registered continuously from 1993 to 1995 at a medical insurance cooperation for industrial workers. The results were as follows; 1. The period prevalence of the medical insurance utilization for low back pain for 3 years from 1993 to 1995 was calculated as 17.1% for male workers and 19.4% for female workers. Most common cause of utilization was other dorsopathies including the herniation of lumbar discs. 2. The utilization rate increased significantly as the present age and the age joining the company got older(p<0.001). As the duration of employment got longer, the utilization rate of the male showed the tendency to increase and that of the female increased significantly(p<0.05). Among male workers employed at cement and concrete manufacturing companies showed higher utilization rate and among female laborers showed significantly higher utilization rate than clerical workers(p<0.01). 3. Annual utilization rate for low back pain didn't show any difference, but the portion of other dorsopathies among cause of utilization showed the tendency to increase from 1993 to 1995. 4. The mean number of claims for outpatient medical care for low back pain differed significantly by age, working duration, type of industries, income level(p<0.05), and the mean of total visiting days for care of low back pain differed significantly by working duration. In conclusion, considering the fact that the medical insurance utilization for low back pain increased annually and other dorsopathies including the herniation of dorsopathies were increasing, an effective preventive or management program for low back pain toward worker employed at industries were required.

  • PDF

Smoking Status and its Related Factors in Male Students of Middle and High Schools in Kwangju (광주지역 남자 중.고등학생의 흡연실태와 흡연관련 요인)

  • Lee, Yun-Ji;Rhee, Jung-Ae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.3 s.43
    • /
    • pp.359-370
    • /
    • 1993
  • To identify the smoking status and its related factors in middle and high school boys in Kwanju a study was performed from 15th to loth of June 1992. Population were selected by two-stage stratified random sampling method and total 3,959 students replied to the self-administered questionnaire survey (1,574 in middle school, 1,664 in academic high school, 712 in business high school). The results were as follows ; 1. The proportion of current smokers was 1.5% in middle schools and 20.1% in high schools. And the smoking rates increased with school grade years (p<0.01). 2. For the motivation of smoking, curiosity was the most frequent factor and the next was temptation by friends. 3. The most common situation on the first experience of smoking was that middle school boys smoked a cigarette which was found in a house, through curiosity, with friends, at home. High school boys smoked a cigarette taken from friends, through curiosity, with friend, on the road or at home. 4. The proportion of smokers who smoke a cigarette regularly was 34.8% among smokers in middle school and 70.2% among smokers in high school. The most proportion of duration of smoking was less than 1 month among middle school boys (20.8%) and more than 2 years among high school boys (43.9%). The first smoking experience was in elementary school among middle school boys and the third grade of middle school in high school students. Most current smokers (73.9% in middle school boys, 65.3% in high school boys) wanted to quit smoking. 5. Smokers had significant association with intimate friend's smoking, mother's and brother's smoking, inharmonious friendships, dissatisfied with home and school life, lower school grades, generous attitude to other smokers, lack of knowledge to passive smoking and no contact to mass media (TV) (p<0.01).

  • PDF

Analysis of $^{99m}Tc-ECD$ Brain SPECT images in Boys and Girls ADHD using Statistical Parametric Mapping(SPM) (통계적 파라미터지도 작성법(SPM)을 이용한 남여별 ADHD환자의 뇌 SPECT 영상비교분석)

  • Park, Soung-Ock;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.31-41
    • /
    • 2004
  • Attention deficit hyperactivity disorder(ADHD)is one of the most common psychiatric disorders in childhood, especially school age children and persisting into adult. ADHD is affected 7.6% in our children, Korea. and persisting into $15{\sim}20%$ in adult. And it is characterized by hyperactivity, inattention and impulsivity. Brain imaging is one of way to diagnosis for ADHD. Brain imaging studies may be provide information two types - structural and functional imaging. Structural and functional images of the brain play an important role in management of neurologic and psyciatric disorders. Brain SPECT, with perfusion imaging radiopharmaceuticals is one of the appropriate test to diagnosis of neurologic and psychiatric diseases. Ther are a few studies about separated analysis between boys and girls ADHD SPECT brain images. Selection of Probability level(P-value) is very important to determind the abnormalities when analysis a data by SPM. SPM is a statistical method used for image analysis and determine statistical different between two groups-normal and ADHD. Commonly used P-value is P<0.05 in statistical analysis. The purpose of this study is to evaluation of blood flow clusters distribution, between boys and girls ADHD. The number of normal boys are 8(6-7y, average : $9.6{\pm}3.9y$) and 51(4-11y, average : $9.0{\pm}2.4$) ADHD patients, and normal girls are 4(6-12y, average : $9{\pm}2.4y$) and 13(2-13y, average $10{\pm}3.5y$) ADHD patiens. Blood flow tracer $^{99m}Tc-ethylcysteinate$ dimer(ECD) injected as rCBF agent and take blood flow images after 30 min. during sleeping by SPECT camera. The anatomical region of hyperperfusion of rCBF in boys ADHD group is posterior cingulate gyrus and hyperperfusion rate is 15.39-15.77% according to p-value. And girls ADHD group appears at posterior cerebellum, Lt. cerbral limbic lobe and Lt. Rt. cerebral temporal lobe. These areas hyperperfusion rate are 24.68-31.25%. Hypoperfusion areas in boys ADHD,s brain are Lt. cerebral insular gyrus, Lt. Rt. frontal lobe and mid-prefrontal lobe, these areas decresed blood flow as 15.21-15.64%. Girls ADHD decreased blood flow regions are Lt. cerebral insular gyrus, Lt. cerebral frontal and temporal lobe, Lt. Rt. lentiform nucleus and Lt. parietal lobe. And hypoperfusion rate is 30.57-30.85% in girls ADHD. The girls ADHD group's perfusion rate is more variable than boys. The studies about rCBF in ADHD, should be separate with boys and girls.

  • PDF

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

Evaluation of Photoneutron Dose for Prostate Cancer Radiation Therapy by Using Optically Stimulated Luminescence Dosimeter (OSLD) (전립선암 방사선치료 시 광자극발광선량계를 이용한 광중성자선량 평가)

  • Lee, Joo-Ah;Back, Geum-Mun;Kim, Yeon-Soo;Son, Soon-Yong;Choi, Kwan-Woo;Yoo, Beong-Gyu;Jeong, Hoi-Woun;Jung, Jae-Hong;Kim, Ki-Won;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.125-134
    • /
    • 2014
  • This study is to provide basic information regarding photoneutron doses in terms of radiation treatment techniques and the number of portals in intensity-modulated radiation therapy (IMRT) by measuring the photoneutron doses. Subjects of experiment were 10 patients who were diagnosed with prostate cancer and have received radiation treatment for 5 months from September 2013 to January 2014 in the department of radiation oncology in S hospital located in Seoul. Thus, radiation treatment plans were created for 3-Dimensional Conformal Radiotherapy (3D-CRT), Volumetric-Modulated Arc Radiotherapy (VMAT), IMRT 5, 7, and 9 portals. The average difference of photoneutron dose was compared through descriptive statistics and variance analysis, and analyzed influence factors through correlation analysis and regression analysis. In summarized results, 3D-CRT showed the lowest average photoneutron dose, while IMRT caused the highest dose with statistically significance (p <.01). The photoneutron dose by number of portals of IMRT was $4.37{\pm}1.08mSv$ in average and statistically showed very significant difference among the number of portals (p <.01). Number of portals and photoneutron dose are shown that the correlation coefficient is 0.570, highly statistically significant positive correlation (p <.01). As a result of the linear regression analysis of number of portals and photoneutron dose, it showed that photoneutron dose significantly increased by 0.373 times in average as the number of portals increased by 1 stage. In conclusion, this study can be expected to be used as a quantitative basic data to select an appropriate IMRT plans regarding photoneutron dose in radiation treatment for prostate cancer.

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

A Mutual P3P Methodology for Privacy Preserving Context-Aware Systems Development (프라이버시 보호 상황인식 시스템 개발을 위한 쌍방향 P3P 방법론)

  • Kwon, Oh-Byung
    • Asia pacific journal of information systems
    • /
    • v.18 no.1
    • /
    • pp.145-162
    • /
    • 2008
  • One of the big concerns in e-society is privacy issue. In special, in developing robust ubiquitous smart space and corresponding services, user profile and preference are collected by the service providers. Privacy issue would be more critical in context-aware services simply because most of the context data themselves are private information: user's current location, current schedule, friends nearby and even her/his health data. To realize the potential of ubiquitous smart space, the systems embedded in the space should corporate personal privacy preferences. When the users invoke a set of services, they are asked to allow the service providers or smart space to make use of personal information which is related to privacy concerns. For this reason, the users unhappily provide the personal information or even deny to get served. On the other side, service provider needs personal information as rich as possible with minimal personal information to discern royal and trustworthy customers and those who are not. It would be desirable to enlarge the allowable personal information complying with the service provider's request, whereas minimizing service provider's requiring personal information which is not allowed to be submitted and user's submitting information which is of no value to the service provider. In special, if any personal information required by the service provider is not allowed, service will not be provided to the user. P3P (Platform for Privacy Preferences) has been regarded as one of the promising alternatives to preserve the personal information in the course of electronic transactions. However, P3P mainly focuses on preserving the buyers' personal information. From time to time, the service provider's business data should be protected from the unintended usage from the buyers. Moreover, even though the user's privacy preference could depend on the context happened to the user, legacy P3P does not handle the contextual change of privacy preferences. Hence, the purpose of this paper is to propose a mutual P3P-based negotiation mechanism. To do so, service provider's privacy concern is considered as well as the users'. User's privacy policy on the service provider's information also should be informed to the service providers before the service begins. Second, privacy policy is contextually designed according to the user's current context because the nomadic user's privacy concern structure may be altered contextually. Hence, the methodology includes mutual privacy policy and personalization. Overall framework of the mechanism and new code of ethics is described in section 2. Pervasive platform for mutual P3P considers user type and context field, which involves current activity, location, social context, objects nearby and physical environments. Our mutual P3P includes the privacy preference not only for the buyers but also the sellers, that is, service providers. Negotiation methodology for mutual P3P is proposed in section 3. Based on the fact that privacy concern occurs when there are needs for information access and at the same time those for information hiding. Our mechanism was implemented based on an actual shopping mall to increase the feasibility of the idea proposed in this paper. A shopping service is assumed as a context-aware service, and data groups for the service are enumerated. The privacy policy for each data group is represented as APPEL format. To examine the performance of the example service, in section 4, simulation approach is adopted in this paper. For the simulation, five data elements are considered: $\cdot$ UserID $\cdot$ User preference $\cdot$ Phone number $\cdot$ Home address $\cdot$ Product information $\cdot$ Service profile. For the negotiation, reputation is selected as a strategic value. Then the following cases are compared: $\cdot$ Legacy P3P is considered $\cdot$ Mutual P3P is considered without strategic value $\cdot$ Mutual P3P is considered with strategic value. The simulation results show that mutual P3P outperforms legacy P3P. Moreover, we could conclude that when mutual P3P is considered with strategic value, performance was better than that of mutual P3P is considered without strategic value in terms of service safety.