• Title/Summary/Keyword: HDP

Search Result 97, Processing Time 0.028 seconds

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Comparison of the Measurement of the Injection Rate of Radioactive Drugs Using 99mTc in Nuclear Medicine (핵의학과에서 99mTc를 이용한 방사성의약품의 투여율 측정 비교)

  • Son, Sang-Joon;Park, Jeong-Kyu;Jung, Dong-Kyung;Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.97-103
    • /
    • 2020
  • This study was conducted by SPECT test at the Department of Nuclear Medicine at Daegu P Hospital from June 1 to October 31, 2019. A 3-way injection material was mounted among inpatients, and a syringe that was administered with radiopharmaceuticals using a 99mTc labeled compound was secured. We tried to find a way to calculate the dose rate of each radiopharmaceutical and increase the dose rate. As a result of measuring the radioactivity of radio-pharmaceuticals using 99mTc, the average dose rate of 60 syringes of all 6 radiopharmaceuticals was 93.26±7.34%, and the average dose rate of 99mTc-DMSA was 77.72%, 15.54% lower than the total. As a way to increase the dosing rate, the average dose rate diluted twice with the remaining amount of syringe after administration using normal saline increased to 95.37±6.99%, and the average dose rate diluted three times increased to 96.32±6.86%. The corresponding sample t-test to compare the pre- and post-dose rates at 1 dilution and 2 and 3 dilutions. As a result of the dilution and 2 dilutions, the probability of significance was 0.013, which was significantly higher than the dilution(p<0.05). The probability of significance for dilution 1 and dilution 3 was 0.016, which was significantly higher than in one dilution(p<0.05). The sum of the average dose rate using the experimental 3-way line was the highest with 98.85±1.42% of 99mTc, 99mTc-ECD 98.82±1.26%, 99mTc-Mebrofenin 98.82 ± 1.16%, 99mTc-HDP 98.74 ± 1.91%, 99mTc -MIBI was 98.69 ± 1.48%, and 99mTc-DMSA was the lowest with 86.47 ± 4.74%. When the number of dilutions was 5 times using 0.5 cc of normal saline and when the number of dilutions was 5 times using 1 cc of normal saline, when the number of dilutions was 5 times using 0.5 cc of normal saline and 1 cc of nomal saline When the number of dilutions was 5 times and the syringe volume was 0.5 cc, there was a statistically significant difference (p<0.05). There was a statistically significant difference when the number of dilutions was 5 times using 1 cc of nomal saline and the number of dilutions was 5 times using 1 cc of normal saline, and the syringe volume was 0.5 cc (p<0.05).

Lesser known indigenous vegetables as potential natural egg colourant in laying chickens

  • Abiodun, Bolu Steven;Adedeji, Aderibigbe Simeon;Abiodun, Elegbeleye
    • Journal of Animal Science and Technology
    • /
    • v.56 no.5
    • /
    • pp.18.1-18.5
    • /
    • 2014
  • Background: A six-week study involving two hundred and fifty (250) Harco Black layer birds at point of lay was conducted to investigate the effects of potential natural colorant on performance and Egg quality traits. The birds were assigned to five (5) dietary treatments, each containing supplements either of control, Baobab Leaf (BL), Waterleaf (WL), Red Pepper (RP), Canthaxanthin (CTX) at 40 g/kg feed and 50 mg/kg feed of natural and commercial colorants, respectively. Results: Performance records shows that there was no significant (p > 0.05) difference in feed intake across the supplements of Red pepper, Water leaf, Canthaxanthin and control diet, however, birds fed Baobab leaf treatment had a significantly lower (p < 0.05) feed intake value (94.07 g) when compared with other treatments. Body weight gain and Hen Day Production were not significant influenced (p > 0.05) by the dietary treatments, although laying hens fed Baobab leaf supplement had lowest mean HDP of 48.80%, while birds fed Red pepper and Water leaf supplement had an average value of 52.79%. There was no significant effect (p > 0.05) of colorants on egg external traits, compared with the control; birds fed Canthaxanthin treatment had higher mean egg weight (51.79 g), egg length (4.55 g), egg breadth (3.29 g); Red pepper treatment had highest mean shell thickness (0.29 g), however these differences were not significant (p > 0.05). Yolk height, Albumen height, Yolk index, and Haugh unit were not significantly affected (p > 0.05) across treatments. Yolk width was lowest (p < 0.05) in Baobab leaf treatment (2.54 cm); Red pepper, Water leaf and Canthaxanthin (2.89 cm, 2.62 cm and 2.89 cm respectively) were not significantly (p > 0.05) different from the control (2.73 cm). Yolk colour score was significantly highest (p < 0.05) in Red pepper treatment (7.50); Water leaf, Baobab leaf and Canthaxanthin ranged between 2.25-3.31 on the DSM yolk colour fan, Control treatment had the lowest yolk colour score (p < 0.05) of 1.31. Conclusion: The study showed Red pepper as a worthy alternative to commercial yolk colorant. Water leaf and baobab are not good substitutes for canthaxanthin as a yolk colourant.

The Asymptotic Throughput and Connectivity of Cognitive Radio Networks with Directional Transmission

  • Wei, Zhiqing;Feng, Zhiyong;Zhang, Qixun;Li, Wei;Gulliver, T. Aaron
    • Journal of Communications and Networks
    • /
    • v.16 no.2
    • /
    • pp.227-237
    • /
    • 2014
  • Throughput scaling laws for two coexisting ad hoc networks with m primary users (PUs) and n secondary users (SUs) randomly distributed in an unit area have been widely studied. Early work showed that the secondary network performs as well as stand-alone networks, namely, the per-node throughput of the secondary networks is ${\Theta}(1/\sqrt{n{\log}n})$. In this paper, we show that by exploiting directional spectrum opportunities in secondary network, the throughput of secondary network can be improved. If the beamwidth of secondary transmitter (TX)'s main lobe is ${\delta}=o(1/{\log}n)$, SUs can achieve a per-node throughput of ${\Theta}(1/\sqrt{n{\log}n})$ for directional transmission and omni reception (DTOR), which is ${\Theta}({\log}n)$ times higher than the throughput with-out directional transmission. On the contrary, if ${\delta}={\omega}(1/{\log}n)$, the throughput gain of SUs is $2{\pi}/{\delta}$ for DTOR compared with the throughput without directional antennas. Similarly, we have derived the throughput for other cases of directional transmission. The connectivity is another critical metric to evaluate the performance of random ad hoc networks. The relation between the number of SUs n and the number of PUs m is assumed to be $n=m^{\beta}$. We show that with the HDP-VDP routing scheme, which is widely employed in the analysis of throughput scaling laws of ad hoc networks, the connectivity of a single SU can be guaranteed when ${\beta}$ > 1, and the connectivity of a single secondary path can be guaranteed when ${\beta}$ > 2. While circumventing routing can improve the connectivity of cognitive radio ad hoc network, we verify that the connectivity of a single SU as well as a single secondary path can be guaranteed when ${\beta}$ > 1. Thus, to achieve the connectivity of secondary networks, the density of SUs should be (asymptotically) bigger than that of PUs.

Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom (Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가)

  • An, Byung Ho;Yeon, Joon Ho;Kim, Soo Young;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.3-11
    • /
    • 2015
  • Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. $^{99m}Tc-HDP$ source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

  • PDF

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF