• 제목/요약/키워드: HA coating

검색결과 356건 처리시간 0.031초

Hydroxyapatite (HA)와 금속 분말 경사 코팅의 기계적 특성 및 생체 적합성 - 대기 열용사 경사코팅 - (The Mechanical Properties and Biocompatibility of Functionally Graded Coatings(FGC) of Hydroxyapatite(HA) and Metallic Powders - Functionally Gradient Coatings of Thermal Spray in Air-)

  • 김은혜;김유찬;한승희;양석조;박진우;석현광
    • 대한금속재료학회지
    • /
    • 제47권1호
    • /
    • pp.13-20
    • /
    • 2009
  • This work presents functionally graded coatings (FGC) of hydroxyapatite (HA) and metallic powders on Ti-6Al-4V implants using plasma spray coating method. HA has been the most frequently used coating material due to its excellent compatibility with human bones. However, because of the abrupt changes in thermomechanical properties between HA and the metallic implant across an interface, and residual stress induced on cooling from coating temperture to room temperature, debonding at the interface occurs in use sometimes. In this work, FGC of HA and Ti or Ti-alloy powders is made to mitigate the abrupt property changes at the interface and the effect of FGC on residual stress release is investigated by evaluating the mechanical bond strength between the implant and the HA coating layers. Thermal annealing is done after coating in order to crystallize the HA coating layer which tends to have amorphous structure during thermal spray coating. The effects of types and compositional ratio of metallic powders in FGC and annealing conditions on the bond strength are also evaluated by strength tests and the microstructure analysis of coating layers and interfaces. Finally, biocompatibility of the coating layers are tested under ISO 10993-5.

침적법에 의한 수산화아파타이트 코팅 금속재의 기초적 연구 (Hydroxyapatite Coating on Ti Plate by a Dipping Method)

  • 이준희;김석영;김영곤;이인섭
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권3호
    • /
    • pp.217-222
    • /
    • 1997
  • Hydroxyapatite(HA)-coated metal composites were made by the dipping method. The specimen substrates were Ti plates with a thickness of 2 mm. The HA coating was carried out in HA-sol for 1 min by the dipping method. The concentration of HA-sol for the coating ranged from 3.28 to 9.99 wt%. Excellent coating was observed on Ti substrate dipped once in 9.99 wt% sol. Preparation of Ti plates by sandblasting provided the better environment for coating HA on Ti surface than non-treated surface. As the concentration of sol increased, the weight change and the coating thickness increased. Above 7 wt% sol, they increased sharply.

  • PDF

플라즈마 용사법에 의한 Hydroxyapatite 코팅의 용사조건에 관한 연구 (Study on the Spraying Parameters of a Plasma-sprayed Hydroxyapatite Coating)

  • 여인웅;안효석
    • 한국세라믹학회지
    • /
    • 제36권4호
    • /
    • pp.444-450
    • /
    • 1999
  • Hydroxyapatite(HA) was spray-coated to alloy substrate(Ti-6Al-4V) using plasma-spray process for bioceramic application The coating morphology composition and crystallinity were influenced by following process parameters ; stand-off distance spray power level and auxiliary gas pressure. These parameters have been systematically varied in the present study to evaluate their relative influence on the coating qual-ity and to seek an optimum spraying condition. Amorphicity and decomposition of HA increased with stand-off distance and the imperfect coating layer was obtained at the short stant-off distance (55mm). The cry-stallinity of HA coating decreased with spray power level and auxiliary gas pressure but the bond strength between the HA coated layer and Ti alloy substrate increased with the spray power level.

  • PDF

Collagen Formation and Adhesion of Human Gingival Fibroblasts on the IBAD Ca-P Coating on Ti

  • B. H. Zhao;F. Z. Cui;Lee, I-S.;W. Bai;H. L. Feng
    • 한국진공학회지
    • /
    • 제12권S1호
    • /
    • pp.10-14
    • /
    • 2003
  • Coatings of hydroxyapatite (HA) and tricalcium phosphate/HA (TCP/HA) on titanium were fabricated by ion beam assisted deposition (IBAD). Significant effect of the Ca-P coatings on human Gingival Fibroblasts (HGFs) attachment and formation of type I collagen were found by using immunofluorescence microscope. TCP/HA and HA coatings exerted more HGFs attachment and collagen I formation. Comparing with HA coating, TCP/HA coating exhibited better responses during the late period of the tests. This investigation indicated that this surface modification method may enhance the biological seal at the cervical level of the titanium dental implants.

Surface Characteristics and Biocompatibility of Titanium Coated with Dentin-derived Hydroxyapatite

  • Kim, Hae-Jin;Son, Mee-Kyung;Lee, Kyung-Ku;Lee, Bo-Ah;Kim, Young-Joon
    • International Journal of Oral Biology
    • /
    • 제37권1호
    • /
    • pp.9-16
    • /
    • 2012
  • The aim of this study was to evaluate surface characteristics and biological properties of the dentin -derived hydroxyapatite (HA) coating on titanium substrate. Dentinderived HA was obtained from extracted human teeth using a calcination method at $850^{\circ}C$. The commercially pure titanium (cp-Ti, ASTM Grade II) was used as a metallic substrate and a radio frequency magnetron sputtering method was employed as a coating method. Scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX) were utilized to investigate the coating aspects and composition. Atomic forced microscopy (AFM) and a surface profiler were used to assess the surface morphology and roughness. Corrosion tests were performed in phosphate-buffered saline at a $36.5{\pm}1^{\circ}C$ in order to determine the corrosion behavior of the uncoated and coated specimens. The biocompatibility of dentin-derived HA coated specimens with fetal rat calvarial cells and human gingival fibroblasts was assessed by SEM and cell proliferation analysis. The results showed that the dentin-derived HA coatings appeared to cover thinly and homogeneously the surfaces without changing of the titanium substrate. The EDX analysis of this the coating surface indicated the presence of Ca and P elements. The mean surface roughness of cp-Ti and dentin-derived coating specimens was $0.27{\mu}m$ and, $1.7{\mu}m$, respectively. Corrosion tests indicated a stable passive film of the dentin-derived HA coating specimens. SEM observations of fetal rat calvarial cells and human fibroblast cells on coated surfaces showed that the cells proliferated and developed a network of dense interconnections. The cells on all specimens proliferated actively within the culture period, showing good cell viability. At day 1 and 3, dentin-derived coating specimens showed 89% and 93% cell viability, respectively, when normalized to cp-Ti specimens. These results suggest that dentin-derived HA coating using the RF magnetron sputtering method has good surface characteristics and biocompatibility.

에어로졸 증착법에 의해 티타늄 기판위에 제조된 다중벽 탄소나노튜브 강화 수산화아파타이트 코팅층 (Multi-walled Carbon Nanotube-Reinforced Hydroxyapatite Coating on Ti Substrates by Aerosol Deposition)

  • 한병동;박동수;류정호;최종진;윤운하;이병국;김현이
    • 한국세라믹학회지
    • /
    • 제45권10호
    • /
    • pp.610-617
    • /
    • 2008
  • Multi-walled carbon nanotube(CNT) reinforced hydroxyapatite composite coating with a thickness of $5{\mu}m$ has been successfully deposited on Ti substrate using aerosol deposition(AD). The coating had a dense microstructure with no cracks or pores, showing good adhesion with the Ti substrate. Microstructural observation using field-emission scanning electron microscopy(FE-SEM) and transmission electron microscopy(TEM) showed that CNTs with original tubular morphology were found in the hydroxyapatite-CNT(HA-CNT) composite coating. Measurements of hardness and elastic modulus for the coating were performed by nanoindentation tests, indicating that the mechanical properties of the coating were remarkably improved by the addition of CNT to HA coating. Therefore, HA-CNT composite coating produced by AD is expected to be potentially applied to the coating for high load bearing implants.

마그네트론 스퍼터링 시스템을 이용한 정형외과용 PEEK의 타이타늄/하이드록시아파타이트 이중 코팅층의 표면 특성 분석 (Surface Characteristics of Titanium/Hydroxyapatite Double Layered Coating on Orthopedic PEEK by Magnetron Sputtering System)

  • 강관수;정태곤;양재웅;우수헌;박태현;정용훈
    • 한국표면공학회지
    • /
    • 제51권3호
    • /
    • pp.164-171
    • /
    • 2018
  • In this study, we have fabricated pure titanium (Ti)/hydroxyapatite (HA) double layer coating on medical grade PEEK from magnetron sputtering system, an investigation was performed whether the surface can be had more improve bio-active for orthopedi/dental applications than that of non-coated one. Pure Ti and HA coating layer were obtained by a radio-frequency and direct current power magnetron sputtering system. The microstructures surface, mechanical properties and wettability of the pure Ti/HA double layer deposited on the PEEK were analyzed by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), nano-indentation, and contact angle test. According to the EDS and XRD results, the composition and crystal structure of pure Ti and HA coated surface were verified. The elastic modulus and hardness value were increased by pure Ti and HA coating, and the pure Ti/HA double layer coating surface has the highest value. The contact angle showed higher value for pure Ti/HA double layered coating specimens than that of non-coated (PEEK) surface.

분사식 섬유보강 코팅으로 보강된 RC보의 성능평가를 위한 유한요소해석 연구 (Finite Element Analysis for Evaluating the Performance of RC Beams Strengthened with SFRP Coating)

  • 하성국;양범주;이행기
    • 한국전산구조공학회논문집
    • /
    • 제22권6호
    • /
    • pp.579-585
    • /
    • 2009
  • 본 연구에서는 분사식 섬유보강 코팅층(sprayed fiber reinforced polymer, SFRP)으로 보강된 RC보의 성능평가를 위하여 유한요소해석을 수행하였다. 이를 위하여 미세역학을 기반으로 한 구성모델(micromechanical constitutive model)(Lee, 2001)과 손상모델(Damage models)(Lee 등, 2000; 2005)을 결합시킨 손상구성모델(damage constitutive model)을 유한요소 프로그램인 ABAQUS에 적용하였다. 유한요소해석 결과를 실험값(Ha, 2007; Ha 등, 2009)과 비교하여 손상구성모델의 정확성을 증명하고자 하였다. 비교분석 결과, 손상구성모델을 유한요소 프로그램에 적용한 해석은 실험결과(Ha, 2007; Ha 등, 2009)를 비교적 잘 예측하고 있음을 보여주었다.

뼈 대체용 생체활성 다공질 세라믹스의 제조 및 특성 (Fabrication and Properties of Bioactive Porous Ceramics for Bone Substitution)

  • 이락형;하정수
    • 한국세라믹학회지
    • /
    • 제45권10호
    • /
    • pp.584-588
    • /
    • 2008
  • Porous hydroxyapatite(HA) and HA-coated porous $Al_2O_3$ possessing pore characteristics required for bone substitutes were prepared by a slurry foaming method combined with gelcasting. The HA coating was deposited by heating porous $Al_2O_3$ substrates in an aqueous solution containing $Ca^{2+}$ and ${PO_4}^{3-}$ ions at $65{\sim}95^{\circ}C$ under ambient pressure. The pore characteristic, microstructure, and compressive strength were investigated and compared for the two kinds of samples. The porosity of the samples was about 81% and 80% for HA and $Al_2O_3$, respectively with a highly interconnected network of spherical pores with size ranging from 50 to $250{\mu}m$. The porous $Al_2O_3$ sample showed much higher compressive strength(25 MPa) than the porous HA sample(10 MPa). Fairly dense and uniform HA coating(about $2{\mu}m$ thick) was deposited on the porous $Al_2O_3$ sample. Since the compressive strength of cancellous bone is $2{\sim}12$ MPa, both the porous HA and HA-coated porous $Al_2O_3$ samples could be successfully utilized as scaffolds for bone repair. Especially the latter is expected suitable for load bearing bone substitutes due to its excellent strength.

콜라겐 코팅된 결정화 하이드록시아파타이트 담체를 이용한 골아세포의 성장 (The Effect of Collagen Coating in Crystallized Hydroxyapatite Scaffold)

  • 김태곤;박원용;김용하;김연정;최식영
    • Archives of Plastic Surgery
    • /
    • 제36권3호
    • /
    • pp.247-253
    • /
    • 2009
  • Purpose: Hydroxyapatite(HA) has been widely used due to its chemical similarity to bone and good biocompatibility. HA is composed of macropores and micropores. Too much irregularities of the micropores are ineffective against the adhesion and proliferation of osteoblast. Many efforts have been tried to overcome these drawbacks. HA crystal coating on the irregular surface of HA scaffold, crystallized HA, is one of the method to improve cell adhesion. Meanwhile, the collagen has been incorporated with HA to create composite scaffold that chemically resembles the natural extracellular matrix components of bone. The authors proposed to examine the effect of collagen - coated crystallized HA on the adhesion and proliferation of osteoblast. Method: HA powder containing $10{\mu}m$ pore size was manufactured as 1 cm pellet size. For the making crystallized HA, 0.1 M EDTA solution was used to dissolve HA powder and heated $100^{\circ}C$ for 48 hours. Next, the crystallized HA pellets were coated with collagen (0.1, 0.5, and 1%). The osteoblasts were seeded into HA pellets and incubated for the various times (1, 5, and 9 days). After the indicating days, methylthiazol tetrazolium (MTT) assay was performed for cell proliferation and alkaline phosphatase (ALP) activty was measured for bone formation. Result: In SEM study, the surface of crystallized HA pellet was more regular than HA pellet. MTT assay showed that the proliferation of osteoblasts increased in a collagen dose - dependent and time - dependent manner and had a maximum effect at 1% collagen concentration. ALP activity also increased in a collagen dose - dependent manner and had a highest effect at 1% collagen concentration. Conclusion: These data showed that crystallization and collagen coating of HA was effective for osteoblast proliferation and ALP activity. Therefore, our results suggest that crystallized - HA scaffold with collagen coating is may be a good strategy for tissue engineering application for bone formation.