• Title/Summary/Keyword: H3K9

Search Result 10,562, Processing Time 0.046 seconds

A Green One-Pot Protocol for Regioselective Synthesis of New Substituted 7,8-Dihydrocinnoline-5(6H)-ones

  • Khalafy, Jabbar;Rimaz, Mehdi;Ezzati, Mahnaz;Prager, Rolf H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.9
    • /
    • pp.2890-2896
    • /
    • 2012
  • A simple regioselective synthesis of cinnoline derivatives was achieved by a one-pot three component synthetic methodology. New substituted 7,8-dihydrocinnolin-5(6H)-ones are prepared via one-pot three component reaction of arylglyoxals with 1,3-cyclohexanedione and dimedone in the presence of hydrazine hydrate in moderate to good yields.

Indole Derivatives II. The Kinetics and Mechanism of the Hydrolysis of Indolylacrylophenone Derivatives (인돌 유도체 II. Indolylacrylophenone 유도체의 가수분해 반응에 대한 메카니즘과 그 반응 속도론적 연구)

  • Lee, Ki-Chang;Ryu, Jung-Wook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.119-126
    • /
    • 1992
  • The kinetics of the hydrolysis of indolylacrylophenone derivatives(IA) was investigated by ultraviolet spectrophotometry in 30% dioxane-$H_2O$ at 25$^{\circ}C$ Rate equations were obtained over a wide pH range. On the basis of rate equation, general base catalysis and Hammett's plot, the mechanism of hydrolysis to the (IA) were proposed: Below pH 3.0, the hydrolysis of (IA) was proportional to hydronium ion concentration, between pH 4.0${\sim}$9.0 neutral water molecule and hydroxide ion were added to carbon-carbon double bond and over pH 10.0 hydrolysis of (IA) was proportional to hydroxide ion concentration.

Comparison of Split versus Subunit Seasonal Influenza Vaccine in Korean Children over 3 to under 18 Years of Age

  • Kang, Seah;Kim, Dong Ho;Eun, Byung Wook;Kim, Nam Hee;Kang, Eun Kyeong;Lee, Byong Sop;Kim, Yun-Kyung
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.3
    • /
    • pp.161-169
    • /
    • 2019
  • Purpose: This study was conducted to compare immunogenicities and reactogenicities of the trivalent inactivated subunit influenza vaccine and split influenza vaccine in Korean children and adolescents. Methods: In total, 202 healthy children aged 36 months to <18 years were enrolled at six hospitals in Korea from October to December 2008. The subjects were vaccinated with either the split or subunit influenza vaccine. The hemagglutinin inhibition antibody titers against the H1N1, H3N2, and B virus strains were measured, and the seroconversion rates, seroprotection rates, and geometric mean titers were calculated. All subjects were observed for local and systemic reactions. Results: Both the split and subunit vaccine groups had similar seroprotection rates against all strains (95.9%, 94.9%, 96.9% vs. 96.0%, 90.9%, and 87.9%). In children aged 36 to <72 months, the seroprotection rates were similar between the two vaccine groups. In children aged 72 months to <18 years, both vaccines showed high seroprotection rates against the H1N1, H3N2, and B strain (98.4%, 98.4%, 98.4% vs. 97.0%, 95.5%, and 91.0%), but showed relatively low seroconversion rates (39.1%, 73.4%, 35.9% vs. 34.3%, 55.2%, and 38.8%). There were more local and systemic reactions in the split vaccine group than in the subunit vaccine group; however, no serious adverse reactions were observed in both groups. Conclusions: Both the split and subunit vaccines showed acceptable immunogenicity in all age groups. There were no serious adverse events with both vaccines.

Synthesis of -4,9-Dione Derivatives (벤조-[f]-인돌-4, 9-디온 유도체의 합성)

  • Lee, Ji-Young;Suh, Myung-Eun
    • YAKHAK HOEJI
    • /
    • v.34 no.1
    • /
    • pp.15-21
    • /
    • 1990
  • -4,9-dione derivatives were prepared from $2-chloro-3-({\alpha}-accetyl-{\alpha}-ethoxycarbonyl-methyl)-1,4-naphthoquinone$ and 2-chloro-3-N-phenylamino-1,4-naphthoquinone. $2-Chloro-3-({\alpha}-acetyl-{\alpha}-ethoxycarbonyl-methyl)-1,4-naphthoquinone$ was reacted with amines to give $2-amino-3-({\alpha}-acetyl-{\alpha}-ethoxycarbonyl-methyl)-1,4-naphthoquinone$ derivatives. Subsequent treatment of $2-amino-3-({\alpha}-acetyl-{\alpha}-ethoxycarbonyl-methyl)-1,4-naphthoquinone$ with sodium ethoxide gave -4,9-dione derivatives. When 2-chloro-3-N-phenylamino-1,4-naphthoquinone reacted with sodium ${\alpha}-cyano$ ethyl acetate, 2-amino-3-ethoxycarbonyl-N-phenyl--4,9-dione was obtained. However, with sodium diethyl malonate, not -4,9-dione but 2-chloro-3-bis-(methoxycarbonyl)-methyl-2H-3-N-phenylamino-1,4-naphthoquinone was obtained.

  • PDF

Transport Rate of Transition Metal Cations through a Bulk Liquid Membrane Containing $NtnOenH_4$ and $NdienOenH_4$ as Carriers (운반체로 $NtnOenH_4$$NdienOenH_4$를 포함한 액체막을 통한 전이금속 양이온의 운반속도)

  • Kim, Hae Joong;Chang, Jeong Ho;Shin, Young Kook
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.2
    • /
    • pp.77-81
    • /
    • 1997
  • The transport rates of transition metal cations were increased in order of Ni(II)$(NtnOenH_4)$and 1,12,15-triaza-3,4;9,10-dibenzo-5,8-dioxacyclo-heptadecane$(NdienOenH_4)$as carriers. The transport rates of transition metal cations was found to be of first order to the salt concentrations. It was also found that the dissociation process in the transport process is rate determining step. From the measurements of the transport rates at various temperatures, the partition free energies of hydration$({\Delta}G_p)$for the transition metal cations were calculated. The results showed that the order of transport rates of transition metal cations was found to be proportional to the magnitudes of negative value of the partition free energies of hydration$({\Delta}G_p)$.

  • PDF

Detection of Helicobacter pylori by Pre-embedding Immunoelectron Microscopy - Comparison with Immunoblotting Method (Pre-embedding Immunoelectron Microscopy를 이용한 Helicobacter pylori의 발견 - Immunoblotting법과 비교 -)

  • Jung, Hae-Seoung;Kim, Eun-Jung;Kim, Eun-A;Park, Ji-Hoe;Jun, Jin-Su;Seo, Ji-Hyoun;Lim, Jae-Young;Choi, Myoung-Bum;Woo, Hyang-Ok;Youn, Hee-Shang;Ko, Gyung-Hyuck;Baik, Seung-Chul;Lee, Woo-Kon;Cho, Myung-Je;Rhee, Kwang-Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.862-874
    • /
    • 2002
  • Purpose : We tried to evaluate whether the detection rate of Helicobacter pylori in gastric biopsy specimens could be improved by using pre-embedding immunoelectron microscopy. Methods : A total of 119 children who complained of upper gastrointestinal symptoms were endoscoped at the Gyeongsang National University Hospital from July, 1996 to July, 1999. Five biopsy specimens(three for urease test, one for hematoxylin-eosin(H & E) staining, and one for preembedding immunoelectron microscopy) were obtained from each antrum and body. Immunoblotting analysis were also performed. Results : Among the 119 patients, H. pylori were found in 116 patients(97.5%) by the immunoelectron microscopy. Among three patients who were found H. pylori negative in immunoelectron microscopy, two patients showed H. pylori in H & E stained slides and one patient was urease test positive(color change within six hours). Urease tests were positive in 107 patients(89.9 %). The positive rate of immunoblotting tests was 81.5%. However, only 13 patients(10.9%) showed H. pylori on the H & E stained antrum or body tissue. Conclusion : In this study, we found H. pylori histopathologically in most of the pediatric patients who complained of upper gastrointestinal symptoms. This study showed that pre-embedding immunoelectron microscopic examinations can be used as a gold standard in the diagnosis of childhood H. pylori infection. However, this method also has limited capacity to detect widely scattered H. pylori compared to the other histopathologic diagnostic methods.

Immobilization of transgenic Nicotiana tabacum cell suspensions for the continuous production of hGM-CSF

  • Roh, Yun-Sook;Lee, Sang-Yoon;Kim, Dong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.341-345
    • /
    • 2003
  • Effect of immobilization on the production of human granulocyte-macrophage colony-stimulating factor (hGM-CSF) by Nicotiana tabacum cells was investigated using polyurethane foam as immobilization matrices. The cell activity and the hGM-CSF production were maintained for 16 days in spite of 3 times of media exchange. Under the same conditions of temperature and agitation rate, maximum concentrations of hGM-CSF in a 500-mL spinner flask and 100-mL Erleuneyer flasks were 17.3 ${\mu}g/L$ and 9.8 ${\mu}g/L$, respectively. Consequently high hGM-CSF production could be possible in spinner flask when the rate and amount of media exchange were optimized.

  • PDF

Synthesis of Organic Carbonates with Alkyl/aryl 4,5-dichloro-6-oxopyridazine-1(6H)-carboxylates and ROH/AlCl3 under Ambient Condition

  • Sung, Gi Hyeon;Kim, Bo Ram;Ryu, Ki Eun;Kim, Jeum-Jong;Yoon, Yong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2758-2764
    • /
    • 2014
  • We demonstrated the synthesis of organic carbonates using alkyl/aryl 4,5-dichloro-6-oxopyridazine-1(6H)-carboxylates and alcohol in the presence of aluminum chloride. Alkyl/aryl 4,5-dichloro-6-oxopyridazine-1(6H)-carboxylates were reacted with alcohol in the presence of $AlCl_3$ in toluene at room temperature to afford the corresponding unsymmetric and symmetric organic carbonates in good to excellent yields. These are efficient and convenient processes. Alkyl/aryl 4,5-dichloro-6-oxopyridazine-1(6H)-carboxylates are solid, stable and non-toxic $CO_2/CO_2R$(Ar) source. It is noteworthy that the reaction is carry out under an ambient and acidic conditions, the easy-to prepare and readily available starting materials and the quantitative isolation of reusable 4,5-dichloropyridazin-3(2H)-one.

Insulation Test for the 22.9 kV Class HTS Power Transmission Cable

  • J.W. Cho;Kim, H.J.;K.C. Seong;H.M. Jang;Kim, D.W.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.48-51
    • /
    • 2003
  • HTS power transmission cable is expected to transport large electric power with a compact size. We are developing a 3-core, 22.9 kV, 50 MVA class HTS power cable, and each core consists of a conductor and shield wound with Bi-2223 tapes, electrical insulation with laminated polypropylene paper (LPP) impregnated with liquid nitrogen. This paper describes the design and experimental results of the model cable for the 22.9 kV, 50 MVA class HTS power transmission cable. The model cable was used the SUS tapes instead of HTS tapes because of testing the electrical characteristics only. The model cable was 1.3 m long and electrical insulation thickness was 4.5 mm. The model cable was evaluated the partial discharge (PD), AC and Impulse withstand voltage in liquid nitrogen. The AC and Impulse withstands voltage and PD inception stress was satisfied with the standard of Korea Electric Power Corporation (KEPCO) in the test results. The 3-core 22.9 kV, 50 MVA class HTS power cable has been designed and manufactured based on these experimental results.

Magnetoelectric Characteristics on Layered Fe78B13Si9/PZT/Fe78B13Si9 Composites for Magnetic Field Sensor (자기센서용 Fe78B13Si9/PZT/Fe78B13Si9 적층구조 소자의 ME 특성)

  • Ryu, Ji-Goo;Jeon, Seong-Jeub
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.181-187
    • /
    • 2015
  • The magnetoelectric characteristics on layered $Fe_{78}B_{13}Si_9/PZT$ and $Fe_{78}B_{13}Si_9/PZT/Fe_{78}B_{13}Si_9$($t_m=0.017$, 0.034mm) composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range and resonance frequency range. The optimal bias magnetic field $H_{dc}$ of these samples was about 23~63 Oe range. The Me coefficient of $Fe_{78}B_{13}Si_9/PZT/Fe_{78}B_{13}Si_9(t_m=0.034mm)$ composites reaches a maximum of $186mV/cm{\cdot}Oe$ at $H_{dc}=63Oe$, f=50 Hz and a maximum of $1280mV/cm{\cdot}Oe$ at $H_{dc}=63Oe$, resonance frequency $f_r=95.5KHz$. The output voltage shows linearity proportional to ac fields $H_{ac}$ and is about U=0~130.6 mV at $H_{ac}=0{\sim}7Oe$, f=50 Hz, U=0~12.4 V at $H_{ac}=0{\sim}10Oe$, $f_r=95.5KHz$(resonance frequency). The optimal frequency(f=50 Hz) of this sample is around the utility ac frequency(f=60 Hz). Therefore, this sample will allow for ac magnetic field sensor at utility frequency and low bias magnetic fields $H_{dc}$.