• Title/Summary/Keyword: H-STEAM

Search Result 678, Processing Time 0.027 seconds

MR spectroscopy using single-shot RF localization technique (단일 RF 펄스를 사용한 3차원 체적 선택 방법을 이용한 MR 스펙트로 스코피)

  • Rim, C.Y.;Chun, K.W.;Ra, J.B.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1989 no.05
    • /
    • pp.51-54
    • /
    • 1989
  • In last several years, a number of volume localization techniques, such as ISIS, VSE, SPARS and STEAM etc., have been developed for the MR spectroscopy. These localizing techniques, however, require application of several RF pulses for the 3-D volume selection and suffer from T1 and T2 decays due to relatively long RF excitation time. In this paper, we propose a single-shot RF pulse localization technique to achieve the localized 3-D volume selection. This technique combines the cylindrical volume selection technique with a radial gradient coil with single-shot RF pulse and the oscillating selection gradient technique, so thai it minimizes the volume selection time. We report some experimental results obtained with the proposed method which appears promising for 3-D volume imaging and localized spectroscopy.

  • PDF

Study on Isolative Determination Methylephedrine Hydrochloride and Ephedrine Hydrochloride in the Mixed Preparation (혼합제제중 Methylephedrine Hydrochloride와 Ephedrine Hydrochloride의 분리정량에 관한 연구)

  • Ko, In-Suk
    • Korean Journal of Pharmacognosy
    • /
    • v.1 no.3
    • /
    • pp.93-99
    • /
    • 1970
  • There have been reported by several workers for the isolation and determination of the amine derivatives as Metbylephedrine Hydrochloride and Ephedrine Hydrochloride adopting neutralization method, steam distillation method, non-aqous titration method, ion-exchange resin method, titration method after acetylation, colorimetric method, gravimetric method, iodine titration method and gas chromatography. Those methods mentioned in above, can be practically applied for the sample which is not mixed one mith the other amine compounds. Presently, it has not shown on the isolative determination of the mixed sample of amine derivatives. In this paper, it is discussed on the isolative determination of Methylephedrine Hydrochloride as the tertiary amine compound and Ephedrine Hydrochloride as the secondary amine compound. According to the results of the experiment, it could be summarized as follows: 1. There is no time-variation on the color reaction of Methylephedrine Hydrochloride and Ephedrine Hydrochloride with the color reagent, bromcresolgreen. And Methylephedrine Hydrochloride and Ephedrine Hydrochloride, respectively, can be determined spectrophotometrically by means oft his color reaction. 2. For the isolation of Methylephedrine Hydrochloride and Ephedrine Hydrochloride from the mixed sample, Methylephedrine Hydrochloride can be eluted by chloroform, while Ephedrine Hydrochloride by the mixed solvent of chloroform and ethylalcohol (2:1), from the celite column adsorbed at pH6.4 followed by extraction with ether undersodium hydroxide alkali re action. 3. When the sample is mixed with quinine hydrochloride, dihydrocodeine bitartate, and noscapine, these mixed compounds can be eliminated by means of stram distillation. 4. When the sample is mixed with chlorpheniramine maleate, dextromethorphan hydrobromide and diphenhydramine hydrochloride, the mixed compounds can be eliminated by means of steam distillation and celite adsorption column chromatography, In conclusion, the isolative determination method for Methylephedrine Hydrochloride and Ephedrine Hydrochloride studied in this paper, indicates with the excellent reproducibility and accuracy.

  • PDF

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

Development of Semicontinuous Measurement System of Ionic Species in PM2.5

  • Hong, Sang-Bum;Chang, Won-il;Kang, Chang-Hee;Lee, Jai H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1505-1515
    • /
    • 2009
  • A new method to semicontinuously determine $PM_{2.5}$ ionic species with a short time resolution is described in detail. In this system, a particle collection section (mixing part, particle collection chamber, and air/liquid separator) was developed. A Y-type connector was used to mix steam and an air sample. The particle collection chamber was constructed in the form of a helix coil and was cooled by a water circulation system. Particle size growth occurred due to the high relative humidity and water absorbed particles were efficiently collected in it. Liquid samples were drained out with a short residence time (0.08-0.1 s). The air/liquid separator was also newly designed to operate efficiently when the flow rate of the air sample was 16.7 L $min^{-1}$. For better performance, the system was optimized for particle collection efficiency with various types of test aerosols such as ($NH_4)_2SO_4,\;NaCl,\;NH_4HSO_4,\;and\;NH_4NO_3$. The particle collection efficiencies were almost 100% at different concentration levels in the range over 500 nm in diameter but 50-90% in the range of 50-500 nm under the following experimental conditions: 15 coil turns, a water flow rate for steam generation of 0.65 mL $min^{-1}$, and an air sample flow rate of 16.7 L $min^{-1}$. Finally, for atmospheric applications, chemical compositions of $PM_{2.5}$ were determined with a time resolution of 20 min on January 11-24, 2006 in Seoul, Korea, and the chemical characteristics of $PM_{2.5}$ ions were investigated.

A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification (반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구)

  • Song, Won-Il;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Shin, Dae-Kun;Tae, Kyung-Eung;Kim, Yong-Sik;Park, Dug-Jun
    • Particle and aerosol research
    • /
    • v.13 no.2
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

Cu2+ ion reduction in wastewater over RDF-derived char

  • Lee, Hyung Won;Park, Rae-su;Park, Sung Hoon;Jung, Sang-Chul;Jeon, Jong-Ki;Kim, Sang Chai;Chung, Jin Do;Choi, Won Geun;Park, Young-Kwon
    • Carbon letters
    • /
    • v.18
    • /
    • pp.49-55
    • /
    • 2016
  • Refuse-derived fuel (RDF) produced using municipal solid waste was pyrolyzed to produce RDF char. For the first time, the RDF char was used to remove aqueous copper, a representative heavy metal water pollutant. Activation of the RDF char using steam and KOH treatments was performed to change the specific surface area, pore volume, and the metal cation quantity of the char. N2 sorption, Inductively Coupled Plasma-Atomic Emission Spectrometer (ICP-AES), and Fourier transform infrared spectroscopy were used to characterize the char. The optimum pH for copper removal was shown to be 5.5, and the steam-treated char displayed the best copper removal capability. Ion exchange between copper ions and alkali/alkaline metal cations was the most important mechanism of copper removal by RDF char, followed by adsorption on functional groups existing on the char surface. The copper adsorption behavior was represented well by a pseudo-second-order kinetics model and the Langmuir isotherm. The maximum copper removal capacity was determined to be 38.17 mg/g, which is larger than those of other low-cost char adsorbents reported previously.

Experimental Studies on Ultrasonic Guided Waves for the On-Line Inspection of Structural Integrity of Nuclear Power Plants (원전 기기 건전성의 온라인 검사를 위한 유도 초음파의 실험적 연구)

  • Eom, Heung-Seop;Kim, Jae-Hee;Song, Sung-Jin;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.331-340
    • /
    • 2004
  • Deployment of an advanced on-line monitoring of the component integrity offers a prospect of improved performance, enhanced safety, and reduced overall cost for nuclear power plants. Ultrasonic guided waves have been known as one of the promising techniques that could be utilized for on-line monitoring. The present work is aimed at developing a new method for on-line monitoring of the pipes during the operation period of nuclear power plants. For this purpose, the steam generator (S/G) tube was selected as an object of tile experiment. Dispersion corves and the incident angles corresponding to the specific modes were calculated for the S/G tube. The modes of guided waves were identified by the time-frequency diagrams obtained by the short time Fourier transform. It was experimentally confirmed that there was no mode conversion when the ultrasonic guided waves passed over the curved region of the S/G tube. An optimum mode of guided wave for the S/G tube was suggested and verified by the experiment.

Assessment of the severe accident code MIDAC based on FROMA, QUENCH-06&16 experiments

  • Wu, Shihao;Zhang, Yapei;Wang, Dong;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.579-588
    • /
    • 2022
  • In order to meet the needs of domestic reactor severe accident analysis program, a MIDAC (Module Invessel Degraded severe accident Analysis Code) is developed and maintained by Xi'an Jiaotong University. As the accuracy of the calculation results of the analysis program is of great significance for the formulation of severe accident mitigation measures, the article select three experiments to evaluate the updated severe accident models of MIDAC. Among them, QUENCH-06 is the international standard No.45, QUENCH-16 is a test for the analysis of air oxidation, and FROMA is an out-of-pile fuel rod melting experiment recently carried out by Xi'an Jiaotong University. The heating and melting model with lumped parameter method and the steam oxidation model with Cathcart-Pawel and Volchek-Zvonarev correlations combination in MIDAC could better meet the needs of severe accident analysis. Although the influence of nitrogen still need to be further improved, the air oxidation model with NUREG still has the ability to provide guiding significance for engineering practice.

Plasmatron Development for a Hydrogen Production (수소 생성을 위한 플라즈마트론 개발)

  • Kim, Seong-Cheon;Chun, Young-Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.48-53
    • /
    • 2006
  • The purpose of this paper is to investigate the optimal condition of the SynGas production by reforming of propane using plasmatron. Plasma was generated by air and arc discharge. The effects of applied steam, $CO_2$ or Ni-catalyst on propane conversion, yield of hydrogen and $H_2/CO$ ratio as well as correlation of syngas were studied. When the variations of $O_2/C_3H_8$ flow ratio, $H_2O/C_3H_8$ flow ratio and $CO_2/C_3H_8$ flow ratio were $0.94{\sim}1.48,\;4.3{\sim}10\;and\;0.8{\sim}3.05$ respectively, Under the condition mentioned above, result of $H_2O/C_3H_8$ flow ratio was maximum $H_2$ concentration, or $28.2{\sim}31.6%$, and result of $H_2O/C_3H_8$ flow ratio with catalyst was minimum CO concentration or $6.6{\sim}7.1%$ and the ratio of hydrogen to carbon monoxide($H_2/CO$) were $3.89{\sim}4.86$.

Valorization of swine manure into low cost activated carbons capable of Cr(VI) removal

  • Gonsalvesh, Lenia;Gryglewicz, Grazyna;Carleer, Robert;Yperman, Jan
    • Advances in environmental research
    • /
    • v.6 no.2
    • /
    • pp.95-111
    • /
    • 2017
  • The valorization of swine manure samples, i.e., de-watered cake (SMc) and solid digestate (SMd), in products with beneficial value, i.e., low cost activated carbons (ACs), is studied. For this purpose slow pyrolysis and steam activation at three different duration times are applied. Additionally, the obtained ACs are characterized and tested towards removal of Cr(VI) from aqueous solutions. It is revealed that BET surface area varies in the range of $236-267m^2/g$ for ACs prepared from SMc sample and in the range of $411-432m^2/g$ for ACs prepared from SMd sample. Despite the low determined surface area of prepared ACs, a high total Cr removal capacity is observed occurring through a "coupled adsorption-reduction" mechanism. Higher Cr(VI) removal capacity is demonstrated for ACs having higher surface area ($q_m$ is 140.9 mg/g according Langmuir modelling). Cr(VI) removal is found to be pH dependent with a maximum at pH 1. However at that pH significant amounts of Cr remain in the solution as Cr(III). At pH 2 lower amount of Cr(VI) is removed compensated by a higher removal of Cr(III) resulting in a higher amount of adsorbed $Cr_{tot}$. Therefore adsorption at pH 2 is found to be appropriate. The removal capacity of the studied ACs towards Cr(VI) is almost independent of activation time.