• 제목/요약/키워드: H Mode

검색결과 2,466건 처리시간 0.039초

RF 스위치 적용을 위한 박막 PZT 엑추에이터의 $d_{31}$ 구동과 $d_{33}$ 구동 특성 비교 (Comparison between $d_{31}\;and\;d_{33}$ actuation characterization of the PZT micro-actuator for RF MEMS switch)

  • 신민재;서영호;최두선;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.467-468
    • /
    • 2006
  • In this work, we present the comparison between $d_{31}\;and\;d_{33}$ mode characterization using the PZT micro-actuator for large displacement. The PZT micro-actuator consisted of Si, PZT, and Pt layer on SOI wafer. The electrode shapes were laminated and interdigitated for $d_{31}\;and\;d_{33}$ mode, respectively. In order to characterize the actuation mode, we measured the displacement using laser interferometer. The maximum displacement of d31 mode was $12.2{\mu}m$ at 10V, the actuation characterization of d31 was better than that of d33 mode. We estimated that displacement of d33 mode would be larger than that of d31 above 30V.

  • PDF

원통형 Inductively Coupled Plasma (ICP) 광원 모드변환의 안테나 의존성 (Antenna Dependancy of Mode Transition in Cylindrical Inductively Coupled Plasma (ICP))

  • 최용성;조수영;김영근;김창복;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.81-86
    • /
    • 2006
  • In this paper, we designed the cylindrical type light source that had a electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the principle of transformer, electrically equivalent circuit of cylindrical type light source was analyzed. According to the parameters of electromagnetic induction which were diameter of coil with 0.3~1.2 mm, number of turns with 4~12 turns, distance with 40~120 mm and RF power with 10~150 W, the electrical and optical properties were measured. When diameter of coil was 0.3 mm, number of turns was 8 turns and distance was 40 mm, the highest brightness of 29,730 $cd/m^2$ was shown with RF power 150 W. The relationship between electromagnetic induction and plasma discharges was shown by mode transition from E-mode to H-mode.

  • PDF

Study of the Librational Motion of $H_2$O Molecules in Hydrates by Neutron Inelastic Scattering

  • Kim, Huhn-Jun;Yoon, Byung-Gook
    • Nuclear Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.1-20
    • /
    • 1979
  • 수화물 결정에 있어서 $H_2O$ 분자의 외부 각 운동을 조사하고저 NaBr-2$H_2O$ 및 BaCl$_2$-2$H_2O$ 분말시료에 대한 중성자비탄성산란실험을 수행하였으며, 관측된 진동수를 모두 이 외부 각 운동에 의한 것으로 보고 다중 및 다준위산란효과를 제거하므로서 평균진동수 분포함수를 구하였다. FG 행열법에 의해서 계산된 진동수의 이론 값들은 모두 복합 mode에 의한 것이였으며 따라서 그 중 포텔샬.에너지분포가 큰 mode로서 관측치에 대한 assignment를 하였다. 소수결합력은 Lippincott-Schroeder 포텐샬함수에서 추산하였으며, 절선형 및 분기형수소결합에 대한 이 함수의 유용성을 $H_2O$ 외부 각 운동 포텐샬함수 모양에 의거하여 검토하였다. 수소결합력의 성질에 대하여 더욱 자세한 자료를 얻기 위해서는 진동수 계산에 H…Y 신축상호작용 운만 아니라 O-H…Y 변각상호작용의 도입이 필요함을 논의하였고 또 $H_2O$ 외부 각 운동에 인어서 mode의 순수성 및 대칭성을 군론을 작용한 방법에 의거하여 논의하였다.

  • PDF

슬라이딩 모드 제어에 의한 불확정성을 가진 대규모 시간지연 선형 계통의 강인 분산 안정화 (Robust Decentralized Stabilization of Large-Scale Time-Delayed Linear Systems with Uncertainties via Sliding Mode Control)

  • 박장환;유정웅
    • 제어로봇시스템학회논문지
    • /
    • 제5권2호
    • /
    • pp.139-144
    • /
    • 1999
  • The present paper is concerned with the robust decentralized stabilization problem of large-scale systems with time delays in the interconnections using sliding mode control. Based on Lyapunov stability theorem and H$_{\infty}$ theory, an existence condition of the sliding mode and a robust decentralized sliding mode controller are newly derived for large-scale systems under mismatched uncertainties. Finally, a numerical example is given to verify the validity of the results developed in this paper.

  • PDF

Two-dimensional LC analyses for increasing operation voltage in the FFS mode with fine slit pixel electrode

  • Kim, H.Y.;Lee, W.H.;Park, J.Y.;Eom, T.J.;Kim, J.P.;Lee, K.H.;Lee, J.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.842-845
    • /
    • 2006
  • We studied for high transmittance panel technology in the FFS mode. We found that fine slit of pixel electrode makes increase of panel transmittance, and at the same time this structure has an issue which is increasing operation voltage (Vop). We analyzed the reason of high Vop in the FFS pixel with fine slit using two-dimensional LC analyses. Finally we suggest the solution which has high transmittance with suitable operating voltage.

  • PDF

Error Concealment Using Intra-Mode Information Included in H.264/AVC-Coded Bitstream

  • Kim, Dong-Hyung;Jeong, Se-Yoon;Choi, Jin-Soo;Jeon, Gwang-Gil;Kim, Seung-Jong;Jeong, Je-Chang
    • ETRI Journal
    • /
    • 제30권4호
    • /
    • pp.506-515
    • /
    • 2008
  • The H.264/AVC standard has adopted new coding tools such as intra-prediction, variable block size, motion estimation with quarter-pixel-accuracy, loop filter, and so on. The adoption of these tools enables an H.264/AVC-coded bitstream to have more information than was possible with previous standards. In this paper, we propose an effective spatial error concealment method with low complexity in H.264/AVC intra-frame. From information included in an H.264/AVC-coded bitstream, we use prediction modes of intra-blocks to recover a damaged block. This is because the prediction direction in each prediction mode is highly correlated to the edge direction. We first estimate the edge direction of a damaged block using the prediction modes of the intra-blocks adjacent to a damaged block and classify the area inside the damaged block into edge and flat areas. Our method then recovers pixel values in the edge area using edge-directed interpolation, and recovers pixel values in the flat area using weighted interpolation. Simulation results show that the proposed method yields better video quality than conventional approaches.

  • PDF

H.264 스케일러블 확장 규격의 고속 부호화를 위한 향상계층의 RD-최적화된 탐색 모드 제한 기법 (RD-Optimized Search-Mode Restriction Method on the Enhancement Layer for Fast Encoding of H.264 Scalable Extension)

  • 이금희;임진영;정경훈;김기두;강동욱
    • 방송공학회논문지
    • /
    • 제13권1호
    • /
    • pp.152-161
    • /
    • 2008
  • 본 논문에서는, 기본계층과 향상계층의 최적 모드 사이의 높은 상관성을 이용하여 기본계층의 모드에 기초하여 향상계층의 부호화 모드를 효율적으로 제한할 때, 생존하는 탐색 모드의 집합은 모드 제한에 의해서 발생할 추가 RD-비용을 최소화하도록 결정되어져야 함을 제시한다. 이 집합에 의거하여 H.264 스케일러블 확장 규격(H.264 SE)을 위한 고속 모드 결정 알고리즘을 구현하였다. 시뮬레이션 결과는 제안하는 알고리즘이 모드들의 조건부 확률에 기초한 기존의 모드 제한 기법에 비해서 RD-성능 면에서 우수함을 입증하고 있다.

H.264의 가변 블록 움직임 보상을 위한 고속 움직임 벡터 탐색 및 모드 결정법 (Fast motion estimation and mode decision for variable block sizes motion compensation in H.264)

  • 이제윤;최웅일;전병우;석민수
    • 대한전자공학회논문지SP
    • /
    • 제40권4호
    • /
    • pp.275-285
    • /
    • 2003
  • 최근 표준화가 완성된 H.264는 가변 크기 블록 움직임 보상, 복수 참조 영상, 그러고 1/4 화소 움직임 벡터 정확도를 지원하고 있다. 그러나 이러한 새로운 부호화 기술은 부호화 효율 향상의 주된 요인이 되긴 하지만 동시에 높은 복잡도의 요인이기도 하다. 따라서 H.264 비디오 표준의 실제 응용 확대를 위해서는 이러한 기술에 대한 속도 향상이 필요하다. 본 논문에서는 부호화 복잡도의 가장 큰 비중을 차지하는 움직임 벡터 추정을 고속화하기 위해 가변 크기 블록 움직임 보상에 적합한 고속 움직임 벡터 탐색법을 제안한다. 또한 H.264가 갖는 다양한 부호화 모두 중 최적치를 빠르게 결정한 수 있는 고속 결정법을 제안한다. 실험 결과, 고속 움직임 벡터 탐색법은 기존 MVFAST/sup [8-10]/에 비해 SAD 계산 수가 4.5배, SATD 계산수는 2.6배 감소하였으며, 고속 모드 결정법의 사용으로 비트율­왜곡 계산치인 RDcost 계산 수는 45%가 감소되었다. 따라서 제안된 방법은 큰 부호화 손실 없이 계산량 감소에 있어서 매우 높은 효율을 제공함을 확인하였다.

Normally Scattering(NS)/Normally Transparent (NT) 고분자 분산형 액정 모드에서 UV 조건에 따른 전기 광학특성 연구 (Study on the Electro-Optic Characteristics Depending on UV Condition in the Normally Scattering(NS)/Normally Transparent(NT) Polymer Dispersed Liquid Crystal Mode)

  • 김미숙;서영현;이명훈;이종문;이택수;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1050-1053
    • /
    • 2003
  • Polymer dispersed liquid crystal mode can be classified into two cases, normally scattering mode (NS) and normally transparent (NT) mode according to an initial state. Electro-optic characteristic NS/NT PDLC mode can be improved by controlling the factors to influence the phase separation. In case of NS PDLC mode, we inspected change of a phase separation as a function of curing temperature for the mixture of E7 and NOA65 with different ratios. When the LC concentration is less than polymer such as LC : NOA65 = 40 : 60wt%, the PDLC cell is influenced strongly by the curing temperature. However, when LC concentration is much less than polymer such as LC : NOA65 : 80 : 20wt%, it is influenced slightly by the curing temperature. In case of NT PDLC mode, we observed change of a phase separation as a function of the ratio of the mixture and UV conditions such as curing temperature, UV intensity The cell made with strong UV intensity and curing temperature of $20^{\circ}C$, in case that the ratio of LC to polymer is 70:30wt%, showed good electro-optic characteristics.

  • PDF

CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과 (The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV)

  • 임채만;장재원;최강현;이상도;고윤석;김우성;김동순;김원동;박평환;최종무
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권3호
    • /
    • pp.351-360
    • /
    • 1995
  • 연구배경: 압력보조는 환자의 흡기시 정해진 양의 양압을 보조하여 상시호흡량을 증가시키거나, 호흡일을 경감시키는 목적으로 쓰이는 기계환기법으로 본 연구는 자발적 호흡이 허용되는 SIMV 및 CPAP 양식에서 PS를 사용할 경우 환자의 호흡역학상 어떤 차이가 있는지 알아보고자 하였다. 방법: 중환자실에 입원하여 호흡부전으로 기계환기중인 환자로 임상적으로 안정되었고 자발적 호흡횟수가 분당 12회 이상인 환자 14명을 대상으로, 먼저 CPAP(3 cm $H_2O$) 양식하에서 0, 5, 10 및 15 cm $H_2O$의 PS를 순서대로 적용하면서 CP-100 pulmonary monitor(Bicore, USA)를 이용하여 호흡역학 지수들을 측정하고 이어서 SIMV 양식으로 바꾸어 같은 방법으로 호흡역학 지수들을 측정하였다. 결과: 1) CPAP 및 SIMV 방식하에서 PS가 호흡역학에 미친 공통된 효과 CPAP 양식하에서 PS를 증가시킴에 따라 상시호흡량은 증가하였고, WOB과 PTP는 감소하였다. SIMV 방식하에서도 PS를 증가시킴에 따라 상시호흡량은 증가하였고, WOB과 PTP 역시 유의하게 감소하였다. 2) CPAP 및 SIMV 방식하에서 PS가 호흡역학에 미치는 효과의 차이 CPAP 방식하에서 PS를 증가시킴에 따라 분당호흡수는 유의한 변동이 없었고, $P_{0.1}$$T_1/T_{TOT}$은 유의하게 감소되었다. SIMV 방식하에서 PS를 증가시킴에 따라 분당호흡수는 유의하게 감소한 반면, $P_{0.1}$$T_1/T_{TOT}$은 유의한 변동이 없었다. 3) CPAP+PS 양식에서 SIMV 단독양식에서와 같은 상시호흡량을 얻는 상태에서의 호흡역학의 비교 동일 환자에서 CPAP+PS 양식으로 SIMV 단독양식에서의 상시호흡량이 얻어지는 상태에서 분당호흡수 WOB, $P_{0.1}$ 등에는 양 방식 간에 차이가 없었으나 PTP와 $T_1/T_{TOT}$은 CPAP+PS 양식이 유의하게 낮았다. 결론: 기계호흡에서 압력보조의 사용은 CPAP 및 SIMV 양식 모두에서 상시호흡량을 증가시키고, 환자의 호흡일, 호흡근 산소소모량 지수를 감소시켰으며, 분당호흡수의 감소는 SIMV 방식에서만 관찰되었고, 중추성호흡추진력의 감소와 호흡근의 지구력지수의 호전은 CPAP 방식에서만 관찰되었다. 한편 상시호흡량이 같은 수준에서의 CPAP+ PS 방법은 SIMV 법에 비해 호흡근의 일효율이 더 높고 호흡근의 지구력지수가 더 우수하였다. 따라서, 기계적환기 유지기나 이탈과정의 환자에서 압력보조의 겸용은 환자의 호흡역학 상태를 개선하는 것으로 사료된다.

  • PDF