• 제목/요약/키워드: H Bridge Cascaded

검색결과 142건 처리시간 0.017초

Fault-Tolerant Control of Cascaded H-Bridge Converters Using Double Zero-Sequence Voltage Injection and DC Voltage Optimization

  • Ji, Zhendong;Zhao, Jianfeng;Sun, Yichao;Yao, Xiaojun;Zhu, Zean
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.946-956
    • /
    • 2014
  • Cascaded H-Bridge (CHB) converters can be directly connected to medium-voltage grids without using transformers and they possess the advantages of large capacity and low harmonics. They are significant tools for providing grid connections in large-capacity renewable energy systems. However, the reliability of a grid-connected CHB converter can be seriously influenced by the number of power switching devices that exist in the structure. This paper proposes a fault-tolerant control strategy based on double zero-sequence voltage injection and DC voltage optimization to improve the reliability of star-connected CHB converters after one or more power units have been bypassed. By injecting double zero-sequence voltages into each phase cluster, the DC voltages of the healthy units can be rapidly balanced after the faulty units are bypassed. In addition, optimizing the DC voltage increases the number of faulty units that can be tolerated and improves the reliability of the converter. Simulations and experimental results are shown for a seven-level three-phase CHB converter to validate the efficiency and feasibility of this strategy.

A Zero Sequence Voltage Injection Method for Cascaded H-bridge D-STATCOM

  • Yarlagadda, Srinivasa Rao;Pathak, Mukesh Kumar
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1088-1096
    • /
    • 2017
  • Load variations on a distribution line result in voltage fluctuations at the point of common coupling (PCC). In order to keep the magnitude of the PCC voltage constant at its rated value and obtain zero voltage regulation (ZVR), a D-STATCOM is installed for voltage correction. Moreover, the ZVR mode of a D-STATCOM can also be used to balance the source current during unbalanced loading. For medium voltage and high power applications, a D-STATCOM is realized by the cascaded H-bridge topology. In the ZVR mode, the D-STATCOM may draw unbalanced current and in this process is required to handle different phase powers leading to deviations in the cluster voltages. Zero sequence voltage needs to be injected for ZVR mode, which creates circulating power among the phases of the D-STATCOM. The computed zero sequence voltage and the individual DC capacitor balancing controller help the DC cluster voltage follow the reference voltage. The effectiveness of the control scheme is verified by modeling the system in MATLAB/SIMULINK. The obtained simulations are further validated by the experimental results using a dSPACE DS1106 and five-level D-STATCOM experimental set up.

A Dynamic Power Distribution Strategy for Large-scale Cascaded Photovoltaic Systems

  • Wang, Kangan;Wu, Xiaojie;Deng, Fujin;Liu, Feng
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1317-1326
    • /
    • 2017
  • The cascaded H-bridge (CHB) multilevel converter is a promising topology for large-scale photovoltaic (PV) systems. The output voltage over-modulation derived by the inter-module active power imbalance is one of the key issues for CHB PV systems. This paper proposed a dynamic power distribution strategy to eliminate the over-modulation in a CHB PV system by suitably redistributing the reactive power among the inverter modules of the CHB PV system. The proposed strategy can effectively extend the operating region of the CHB PV system with a simple control algorithm and easy implementation. Simulation and experimental results carried out on a seven-level CHB grid-connected PV system are shown to validate the proposed strategy.

Cascaded 멀티-레벨 인버터 시스템에 관한 연구 (A Study on the Caseded-Type Multi-Level Inverter System)

  • 강대욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.321-324
    • /
    • 2000
  • 멀티-레벨 인버터 구조는 크게 세 가지가 있다 NPC 구조, 플라잉 커패시터 구조, 그리고 H-bridge 단위 인버터 셀을 종속적으로 연결한 cascaded 구조가 그것이다. 이중에서 cascaded 구조는 지금까지 홀수 레벨만 존재하는 것으로 알려졌다 본 논문에서는 이것을 짝수 레벨로 확장한 새로운 구조를 제안하고 홀수 짝수 레벨 모두에 적용이 가능한 새로온 PWM 기법을 제안하고자 한다. 제안한 기법은 컴퓨터 시뮬레이션 및 실험으로 그타당성을 입증하고자 한다.

  • PDF

Voltage Balance Control of Cascaded H-Bridge Rectifier-Based Solid-State Transformer with Vector Refactoring Technology in αβ Frame

  • Wong, Hui;Huang, Wendong;Yin, Li
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.487-496
    • /
    • 2019
  • For a solid-state transformer (SST), some factors, such as signal delay, switching loss and differences in the system parameters, lead to unbalanced DC-link voltages among the cascaded H-bridges (CHB). With a control method implemented in the ${\alpha}{\beta}$ frame, the DC-link voltages are balanced, and the reactive power is equally distributed among all of the H-bridges. Based on the ${\alpha}{\beta}$ frame control, the system can achieve independent active current and reactive current control. In addition, the control method of the high-voltage stage is easy to implement without decoupling or a phase-locked loop. Furthermore, the method can eliminate additional current delays during transients and get the dynamic response rapidly without an imaginary current component. In order to carry out the controller design, the vector refactoring relations that are used to balance DC-link voltages are derived. Different strategies are discussed and simulated under the unbalanced load condition. Finally, a three-cell CHB rectifier is constructed to conduct further research, and the steady and transient experimental results verify the effectiveness and correctness of the proposed method.

다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석 (Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges)

  • 한병문;소용철;김현우
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.94-102
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

직렬통신을 이용한 H-브릿지 멀티레벨 인버터의 PWM 구현방법 (The Simplified PWM Method using Serial Communication in Cascaded H-Bridge Multilevel Inverter)

  • 박영민;유한승;이현원;이세현;이충동;유지윤
    • 전력전자학회논문지
    • /
    • 제9권6호
    • /
    • pp.620-627
    • /
    • 2004
  • H-브릿지 멀티레벨 인버터는 여러 개의 단상 Power Cell을 직렬로 연결함으로써 저전압 전력용 반도체를 사용하여 고전압을 얻을 수 있고, 정현파에 가까운 출력전압 파형을 얻을 수 있는 멀티레벨 인버터 토폴로지이다. 본 논문은 산업현장에서 신뢰성을 인정받아 많이 사용되고 있는 직렬통신 방식의 일종인 CAN통신 인터럽터를 이용한 H-브릿지 멀티레벨 인버터 Power Cell의 PU 동기화 및 위상전이 방법에 관한 것이다. 제안된 방법의 주요 장점은 주제어기와 셀 제어기 사이에 직렬통신(CAN)을 사용함으로써 주제어기와 셀 제어기의 신호선의 단순화, 주제어기의 부담 감소, Power Cell의 모듈화, 셀 단위의 보호동작 용이, 확장성 향상 그리고 제어 신호 및 Power Cell의 신뢰성을 향상에 있다. 13레벨로 구성된 H-브릿지 멀티레벨 인버터 시험을 통해 제안된 방법의 타당성과 신뢰성을 입증하였다.

스텝펄스형 멀티레벨 인버터를 위한 RMS 등가형의 새로운 사인파 변조법 (Equivalent RMS Sine-wave Modulation of the Step-pulse type Multi-level Inverter)

  • 진선호;곽준호;조관준;오진석
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.239-246
    • /
    • 2006
  • 본 논문에서는 스텝 펄스형의 멀티레벨 인버터에 적용하기 위한 새로운 사인파 변조기법을 제안하고자 한다. 제안된 변조기법은 레벨수의 증가에 무관하게 스위칭 각의 계산이 쉽고, 각각의 스텝에서 이상적인 정현파와 수학적으로 동일한 실효치를 출력하도록 설계되었으며, 높은 출력레벨의 스텝펄스형 멀티레벨 인버터에서 정현파를 근사적으로 추종하는 파형을 생성할 수 있다. 본 논문에서는 셀 전압비를 이용하여 출력 레벨을 확장한 3셀 구조의 13레벨 케스케이드 H-브리지형 멀티레벨 인버터에 대하여 제안된 변조기법을 적용하였으며 시뮬레이션 및 실험을 통하여 확인하였다.

Control Strategies for Multilevel APFs Based on the Windowed-FFT and Resonant Controllers

  • Han, Yang
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.509-517
    • /
    • 2012
  • This paper presents control strategies for cascaded H-bridge multilevel active power filters (APFs). A current loop controller is implemented using a proportional-resonant (PR) regulator, which achieves zero steady-state error at target frequencies. The power balancing mechanism for the dc-link capacitor voltages is analyzed and a voltage balancing controller is presented. To mitigate the picket-fence effect of the conventional FFT algorithm under asynchronous sampling conditions, the Hanning Windowed-FFT algorithm is proposed for reference current generation (RCG). This calculates the frequency, amplitude and phase of individual harmonic components accurately and as a result, selective harmonic compensation (SHC) is achieved. Simulation and experimental results are presented, which verify the validity and effectiveness of the devised control algorithms.

Sequence Pulse Modulation for Voltage Balance in a Cascaded H-Bridge Rectifier

  • Peng, Xu;He, Xiaoqiong;Han, Pengcheng;Lin, Xiaolan;Shu, Zeliang;Gao, Shibin
    • Journal of Power Electronics
    • /
    • 제17권3호
    • /
    • pp.664-673
    • /
    • 2017
  • With the development of multilevel converters, cascaded single-phase H-bridge rectifiers (CHBRs) has become widely adopted in high-voltage high-power applications. In this study, sequence pulse modulation (SPM) is proposed for CHBRs. SPM is designed to balance the dc-link voltage and maintain the smooth changes of switch states. In contrast to phase disposition modulation, SPM balances the dc-link voltage even after removing the load of one submodule. The operation principle of SPM is deduced, and the unbalance degree of SPM is analyzed. All the proposed approaches are experimentally verified through a prototype of a four-module (nine-level) CHBR. Conclusions are drawn in accordance with the results of SPM and its imbalance degree analysis.