• Title/Summary/Keyword: H Bridge Cascaded

Search Result 142, Processing Time 0.025 seconds

Dynamic Performance Analysis of Unified Power Quality Conditioner with Cascaded H-Bridges (다중브리지로 구성된 UPQC(Unified Power Quality Conditioner)의 동적 성능분석)

  • Cho, Yun-Ho;Bae, Byung-Yeol;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.241-243
    • /
    • 2006
  • This paper describes experimental analysis of UPQC, which is composed of cascaded H-bridges and single-phase multi-winding transformers. The operational characteristic was analyzed through experimental works with a scaled model, and simulations with PSCAD/EMTDC. The UPQC proposed in this paper can be directly connected to the distribution line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual UPQC system applicable for the actual distribution system.

  • PDF

Voltage Dip Compensation Algorithm Using Multi-Level Inverter (멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구)

  • Yun, Hong-Min;Kim, Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.

Predictive Current Control for Multilevel Cascaded H-Bridge Inverters Based on a Deadbeat Solution

  • Qi, Chen;Tu, Pengfei;Wang, Peng;Zagrodnik, Michael
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.76-87
    • /
    • 2017
  • Finite-set predictive current control (FS-PCC) is advantageous for power converters due to its high dynamic performance and has received increasing interest in multilevel inverters. Among multilevel inverter topologies, the cascaded H-bridge (CHB) inverter is popular and mature in the industry. However, a main drawback of FS-PCC is its large computational burden, especially for the application of CHB inverters. In this paper, an FS-PCC method based on a deadbeat solution for three-phase zero-common-mode-voltage CHB inverters is proposed. In the proposed method, an inverse model of the load is utilized to calculate the reference voltage based on the reference current. In addition, a cost function is directly expressed in the terms of the voltage errors. An optimal control actuation is selected by minimizing the cost function. In the proposed method, only three instead of all of the control actuations are used for the calculations in one sampling period. This leads to a significant reduction in computations. The proposed method is tested on a three-phase 5-level CHB inverter. Simulation and experimental results show a very similar and comparable control performance from the proposed method compared with the traditional FS-PCC method which evaluates the cost function for all of the control actuations.

Multilevel Inverter using Two 5-level Inverters Connected in Series (두 대의 5-레벨 인버터의 직렬결합을 이용한 멀티레벨인버터)

  • Choi, Won-Kyun;Kwon, Cheol-Soon;Hong, Un-Taek;Kang, Feel-Soon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.376-380
    • /
    • 2010
  • This paper presents a circuit configuration of multilevel inverter to increase the number of output voltage levels by using conventional 5-level inverters connected in series. Most of all it can maximize the number of output voltage levels by employing input voltage sources, which have the power of five. When it synthesizes the same number of output voltage levels, the proposed inverter can save the number of switching devices compared with the conventional cascaded H-bridge cell inverter. So it can reduce the size, cost, power consumption of the system. We implemented computer-aided simulation and experiments for a 25-level inverter employing two 5-level inverters.

Simulation based Comparative Loss Analysis and Output Characteristic for 25MW Class of High Power Multi-level Inverters (25MW급 대용량 멀티레벨 인버터의 시뮬레이션 기반 손실해석과 출력특성 비교 분석)

  • Kim, I-Gim;Park, Chan-Bae;Baek, Jei-Hoon;Kwak, Sang-Shin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.337-343
    • /
    • 2015
  • The multi-level inverters are highly efficient for high-power and medium-voltage AC driving applications, such as high-speed railway systems and renewable energy resources, because such inverters generate lower total harmonic distortion (THD) and electromagnetic interface (EMI). Lower switching stress occurs on switching devices compared with conventional two-level inverters. Depending on the multi-level inverter topology, the required components and number of switching devices are different, influencing the overall efficiency. Comparative studies of multi-level inverters based on loss analysis and output characteristic are necessary to apply multi-level inverters in high-power AC conversion systems. This paper proposes a theoretical loss analysis method based on piecewise linearization of characteristic curves of power semiconductor devices as well as loss analysis and output performance comparison of five-level neutral-point clamped, flying capacitor inverters, and high-level cascaded H-bridge multi-level inverters.

Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Cascaded H-Bridge STATCOM (STATCOM에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상)

  • Kwon, Byung-Ki;Jung, Seung-Ki;Kim, Tae-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.4
    • /
    • pp.321-329
    • /
    • 2015
  • The static synchronous compensator (STATCOM) of cascaded H-bridge configuration accompanying multiple separate DC sides is inherently subject to the problem of uneven DC voltages. These DC voltages in one leg can be controlled by adjusting the AC-side output voltage of each cell inverter, which is proportional to the active power. However, when the phase current is extremely small, large AC-side voltage is required to generate the active power to balance the cell voltages. In this study, an alternative zero-sequence current injection method is proposed, which facilitates effective cell balancing controllers at no load, and has no effect on the power grid because the injected zero sequence current only flows within the STATCOM delta circuit. The performance of the proposed method is verified through simulation and experiments.

Individual DC Voltage Balancing Method at Zero Current Mode for Cascaded H-bridge Based Static Synchronous Compensator

  • Yang, Zezhou;Sun, Jianjun;Li, Shangsheng;Liao, Zhiqiang;Zha, Xiaoming
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.240-249
    • /
    • 2018
  • Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the software-based individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. Field test in a 10kV STATCOM confirms the performance of the proposed method.

A Single-Source Photovoltaic Power Conditioning System using Forward-Flyback converter and Asymmetric cascaded Multi Level H-bridge Inverter (포워드-플라이백 컨버터와 단일 전원 비대칭 다단식 H-bridge 다중 레벨 인버터를 적용한 태양광 전력 조절 시스템)

  • Jeon, Young-tae;Sundar, Mohana;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.73-74
    • /
    • 2016
  • 본 논문은 포워드-플라이백 컨버터와 태양광 단일 전원 비대칭 다단식 H-bridge 다중 레벨 인버터를 적용한 태양광 전력 조절 시스템에 관한 논문이다. 이는 기존에 연구되었던 대칭형 다단식 H-Brdige 다중 레벨 인버터나 플라이백 컨버터를 사용한 태양광 전력 조절 시스템의 단점을 보완 한 것이다. 대칭형 다단식 멀티 레벨 인버터는 각 H-Bridge 구조 마다 독립된 전원이 필요하지만, 포워드-플라이백(Foward-Flyback) 컨버터를 접목시켜 단일 태양광 전원으로 하나의 다단식 H-Brdige 인버터를 구성 할 수 있고, 또한 기존의 플라이백 컨버터를 포워드-플라이백 컨버터로 대체 하면서 기존 대비 대용량 설비가 용이하고 효율적인 태양광 전력 조절 시스템을 설계 할 수 있다. 제안한 시스템의 가능성을 확인하기 위하여, PSIM 시뮬레이션을 통해 계통 연계형 1kW급 태양광 시스템의 최대 전력 추종 제어(Maximum Power Point Tracking)와 인버터의 $V_{dc}$ 전압 제어를 확인하였다.

  • PDF

A Study On the Characteristics of Cascaded PWM Converter for IUT (IT기반 지능형 다기능 변압기용 cascade형 PWM 컨버터의 특성 연구)

  • Ahn, Joonseon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • In this paper, novel PWM generation method for cascaded H-bridge PWM converter is proposed. The proposed method can solve the unvalancing problem between H-bridges which consist cascade PWM converter without any injection of redundancy switching pattern for solving the load of switches forced from voltage reference of controller.

Switching signal of Cascaded HBML inverter employing the identical Transformer (동일한 변압기 용량을 갖는 직렬형 HBML 인버터의 스위칭 신호)

  • Lee, S.H.;Park, S.J.;Moon, C.J.;Ahn, J.W.;Gwon, S.J.;Lee, M.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.651-654
    • /
    • 2005
  • In this paper, an efficient switching pattern to equalize the size of transformer is proposed for a multi-level inverter employing cascaded transformers. It is based on the prior selected harmonic elimination PWM(SHEPWM) method. Because the maximum magnetic flux imposed on each transformer becomes exactly equal each to each, all transformers can be designed with the same size regardless of their position. Therefore, identical full-bridge inverter units can be utilized, thus improving modularity and manufacturability. The fundamental idea of the proposed switching pattern is illustrated and the analyzed theoretically. The validity of the proposed switching strategy is verified by experimental results.

  • PDF