• Title/Summary/Keyword: H형

Search Result 164, Processing Time 0.023 seconds

Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Reinforced bars (철근으로 보강한 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동)

  • Yoo, Yeong Chan;Shin, Kyung Jae;Oh, Young Suk;Lee, Seung Joon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.377-390
    • /
    • 1997
  • The objective of this study is to investigate the structural behavior of concrete-filled steel tubular column to H-beam connections with reinforced bar. As a preliminary test, simple tensile test on the column to H-beam connections stiffened were conducted. The parameters of tensile test are the diameters of each rebars. The simple tensile test were conducted to 5 kinds of specimens. Estimating the load. displacement and strain for specimens, the result of tensile test were compared with the results of main test. On the basis of simple tensile test, tests are conducted to montonic and cyclic loading column to H-beam connections with the same diameters of rebars. Specimens of 5 are made for monotonic and cyclic loading test. In analysis, estimating the yielding strength and maximum strength of specimens on the basis of yield line theory, strength formula of beam-to column connections with concrete-filled steel tubular column was suggested.

  • PDF

Behavior of Concrete-Filled Square Steel Tubular Column-H Beam Connections with Plates (강판보강 콘크리트충전 각형강관 기둥-H형강보 접합부의 거동)

  • Yoo, Yeong Chan;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.161-175
    • /
    • 1998
  • The objective of this study is to investigate the structural behavior of Concrete-Filled Steel Tubular Column-H Beam connections with plate stiffeners. The first, we made experiment on the Column to H-beam flange connections stiffened with simple tensile loading. The paramaters of tensile experiment are the area of each plates. The simple tensile experiment is conducted to 5 kinds of specimens. Eestimating the load, displacement, and strain from each kind, we compared them with results of second experiment. The second, we made experiment on the Column to H-beam connections stiffened with the sames under monotonic and cyclic load. we made specimens of 5 for the second experiment. In analysis, comparing each strengthes and stiffnesses we estimated deformation capacity. Comparing and estimating each yielding strength ratios and maxium-strength ratios on the basis of Yield line theory, we suggested new Strength Formula of Beam-to-Column Connections.

  • PDF

Structural Analysis and Design of the H-typed Railway Tie (H형 침목의 구조해석 및 설계)

  • Kim, Hae-Gon;Bae, Hyun-Ung;Lee, Chin-Ok;Lim, Nam-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4532-4541
    • /
    • 2013
  • With speed up of railway, the demand for safety of the railroad transportation is on the increase in Korea's conventional railways. In additions, freight trains with heavier axle load are required to run conventional railways. In order to solve these requirements, the increase of rail weight and the application of long rail system have been underway in conventional railways. However, the research on ties that is absolutely influencing the track stiffness in ballasted tracks has not been much progress. In this paper, the new H-typed tie is developed to increase the track stiffness and reduce the track irregularity. And from the structural analysis by FE program, the intial design drawing of the new H-typed tie is proposed.

Hysteretic Behavior Characteristics of SM490-TMC Steel Column (SM490-TMC 강재를 적용한 기둥부재 이력거동의 특성)

  • Chang, Kyong Ho;Jang, Gab Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.833-840
    • /
    • 2006
  • In design of steel column member using TMCP steels, hysteretic behavior characteristics of steel column must be clarified. To predict hysteretic behavior of steel column using TMCP steels, a cyclic plasticity model is necessary which can consider the mechanical characteristics and stress-strain relationship of TMCP steels. In this paper, a cyclic plasticity model of SM490-TMC was formulated based on monotonic and cyclic loading tests. The formulated cyclic plasticity model was applied to 3-dimensional finite element analysis. Hysteretic behavior characteristics of steel circular column and H-section column using SM490-TMC was presented by carrying out numerical analysis. Also, influence of SM490-TMC on hysteretic behavior of steel column was presented by comparing analysis results both SM490 and SM490-TMC steel column.

Third-Party Financing Contracts Between Energy Users and Energy Saving Companies (비대칭정보하에서의 최적계약 도출 -에너지절약시장)

  • Kang, Kwang-Kyu
    • Journal of Environmental Policy
    • /
    • v.8 no.4
    • /
    • pp.75-94
    • /
    • 2009
  • The process of obtaining third-party financing contacts was analyzed via a two-stage game model: a "signaling game" for the first stage,and a "principal-agent model" for the second stage. The two-stage game was solved by a process of backward induction. In the second stage game, the optimal effort level of the energy saving company (ESCO), the optimal compensation scheme of the energy user, and the optimal payoffs for both parties were derived for each subgame. The optimal solutions forthe different subgames were then compared with each other. Our main finding was that if there is some restriction on ESCO's revenue (e.g. a progressive sales tax) that causes ESCO's revenue toincrease at a decreasing rate, then the optimal sharing ratio is uniquely determined at a level of strictly less than one under a linear compensation scheme, i.e. a unique balance exists. Subgames have a unique equilibrium arrived at separately for each situation,. Within this equilibrium, energy users accept energy audit proposals from H-type ESCOs with high levels of technology, but reject proposals from L-type ESCOs with low levels of technology. While L-type ESCOs cannot attain profits in the third-party financing market, H-type ESCOS can pocket the price differential between L-type and H-type audit fees. Accordingly, revenues in an H-type ESCO equilibrium increase not only in line with the technology of the ESCO inquestion, but also faster than in an L-type equilibrium due to more advanced technology. At the same time, energy users receive some positive payoff by allowing ESCOs to perform third-party financing tasks within their existing energy system without incurring any extra costs.

  • PDF

Behavior of Concrete-Filled Square Steel Tubular Column to H-Beam Connections using Angles (앵글을 이용한 콘크리트충전 각형강관기둥-H형강보 접합부의 거동)

  • Lee, Jae Seung;Kim, Jae Keon;Shin, Kyung Jae;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.2 s.39
    • /
    • pp.191-199
    • /
    • 1999
  • This paper is the first step on the study of the industrialization of the mid-story steel building structures. The purpose of this study is to investigate the structural behavior of concrete-filled square steel tubular column to H-beam connections using angles and high tension bolts. The tests are carried out with five types of specimens under static loading and the main parameter is the thickness of angles. Yield-line theory which obtains connection strength by way of the lowest value based on upper-limit theory is applied to predict strength formulas.

  • PDF

Behavior of Steel Beam Connections under Cyclic Loading (반복하중을 받는 철골보 접합부의 거동)

  • 이승준;김상배
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.23-32
    • /
    • 1999
  • Behavior of H-beam connections under cyclic loadings is investigated experimentally in this study. The purpose of this study is to study the effect of steel properties and coping shape on the hysteretic behavior of H-beam connections. Five beam-to-column connection specimens were fabricated and tested under cyclic loadings. The load-rotation curves of the beam connections were mainly obtained. Deformation capacity and energy dissipation capacity of the connections are compared each other. The connections fabricated from SS400 showed good deformability and energy dissipation capacity, but those from SM490 showed brittle fracture at the connection. The coping shape at the connections showed a little difference in cyclic behavior.

  • PDF

Behavior of CFT Column to H-Beam Full-Scale Connections with External T-Stiffeners (T-스티프너 보강 CFT 기둥 - H형강보 실대형 접합부의 거동)

  • Kim, Young Ju;Kang, Chang Hoon;Shin, Kyung Jae;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.715-723
    • /
    • 2001
  • This paper represents the behavior of CFT column to H-beam full-scale connection with external T-stiffener. 6 specimens whose T-stiffeners which are compounded of vertical element and horizontal element were made under the parameter of the strength ratio of each elements(vertical element and horizontal element in T-stiffener) to the beam full plastic moment. The analysis-parameters demonstrated in the base of the data that we get in experiment are strength stiffness, and plastic rotational capacity. All of specimen showed stable hysteretic behavior, and the horizontal element is more critical than vertical element in strength and stiffness. The mean beam plastic rotation of all specimen except the TS-2 specimen is 2.97% rad.

  • PDF