• Title/Summary/Keyword: Gyeongnam

Search Result 3,464, Processing Time 0.026 seconds

Evaluation of indirect N2O Emission from Nitrogen Leaching in the Ground-water in Korea (우리나라 농경지에서 질소의 수계유출에 의한 아산화질소 간접배출량 평가)

  • Kim, Gun-Yeob;Jeong, Hyun-Cheol;Kim, Min-Kyeong;Roh, Kee-An;Lee, Deog-Bae;Kang, Kee-Kyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1232-1238
    • /
    • 2011
  • This experiment was conducted to measure concentration of dissolved $N_2O$ in ground-water of 59 wells and to make emission factor for assessment of indirect $N_2O$ emission at agricultural sector in agricultural areas of Gyeongnam province from 2007 to 2010. Concentrations of dissolved $N_2O$ in ground-water of 59 wells were ranged trace to $196.6{\mu}g-N\;L^{-1}$. $N_2O$ concentrations were positively related with $NO_3$-N suggesting that denitrification was the principal reason of $N_2O$ production and $NO_3$-N concentration was the best predictor of indirect $N_2O$ emission. The ratio of dissolved $N_2O$-N to $NO_3$-N in ground-water was very important to make emission factor for assessment of indirect $N_2O$ emission at agricultural sector. The mean ratio of $N_2O$-N to $NO_3$-N was 0.0035. It was greatly lower than 0.015, the default value of currently using in the Intergovernmental Panel on Climate Change (IPCC) methodology for assessing indirect $N_2O$ emission in agro-ecosystems (IPCC, 1996). It means that the IPCC's present nitrogen indirect emission factor ($EF_{5-g}$, 0.015) and indirect $N_2O$ emission estimated with IPCC's emission factor are too high to use adopt in Korea. So we recommend 0.0034 as national specific emission factor ($EF_{5-g}$) for assessment of indirect $N_2O$ emission at agricultural sector. Using the estimated value of 0.0034 as the emission factor ($EF_{5-g}$) revised the indirect $N_2O$ emission from agricultural sector in Korea decreased from 1,801,576 ton ($CO_2$-eq) to 964,645 ton ($CO_2$-eq) in 2008. The results of this study suggest that the indirect Emission of nitrous oxide from upland recommend 0.0034 as national specific emission factor ($EF_{5-g}$) for assessment of indirect $N_2O$ emission at agricultural sector.

Expanded Uses and Trend of Domestic and International Research of Rose of Sharon(Hibiscus syriacus L.) as Korean National Flower since the Protection of New Plant Variety (식물신품종보호제도 이후 나라꽃 무궁화의 국내외 연구동향 및 확대 이용 방안)

  • Kang, Ho Chul;Kim, Dong Yeob;Wang, Yae Ga;Ha, Yoo Mi
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.5
    • /
    • pp.49-65
    • /
    • 2019
  • This study was carried out to investigate the domestic and international development of a new cultivar of the Rose of Sharon (Hibiscus syriacus L.), the Korean national flower, and the protection of the new plant variety. In addition, it will be used as basic data for the expansion of domestic distribution, promoting oversea export, and expanding the range of landscape architectural use. A total of 97 varieties received plant variety protection rights from the Korea Seed & Variety Service from 2004 to 2018. The selection criteria were plants having unique flowers, growth habits, and variegated leaves. Some cultivars with unique features, such as flower size, shape, and red eyes were available for focus planting. Plant varieties with tall and strong growth patterns have been highly valuable for street and focus planting. Cultivars with dwarf stems and compact branches are utilized for pot planting and bonsai. The protected cultivars were mostly single flower varieties, with two semi-double flowers. There were 57 cultivars of pink flowers with red eyes and 21 cultivars of white flowers with red eyes. There were 61 cultivars developed by crossing, 23 cultivars through interspecific hybridization and 7 cultivars developed through radiation treatment and mutation. The Hibiscus cultivars registered to the United States Patent and Trademark Office (USPTO) consisted of seven cultivars each from the United States, the United Kingdom, and the Netherlands, four from South Korea, and three from Belgium. The Hibiscus cultivars registered to the European Community Plant Variety Office (CPVO) consisted of 16 cultivars from France, 9 from the Netherlands, 5 from the UK and 1 from Belgium. The cultivars that received both plant patent and plant breeder rights in the United States and Canada were 'America Irene Scott', 'Antong Two', 'CARPA', 'DVPazurri', 'Gandini Santiago', 'Gandini van Aart', 'ILVO347', 'ILVOPS', 'JWNWOOD 4', 'Notwood3', 'RWOODS5', 'SHIMCR1', 'SHIMRR38', 'SHIMRV24', and 'THEISSHSSTL'. 'SHIMCR1' and 'SHIMRV24' acquired both domestic plant protection rights and overseas plant patents. The 14 cultivars that received both US plant patents and European protection rights were 'America Irene Scott', 'Bricutts', 'DVPAZURRI', 'Gandini Santiago', 'Gandini van Aart', 'JWNWOOD4', 'MINDOUB1', 'MINDOUR1', 'MINDOUV5', 'NOTWOOD3', 'RWOODS5', 'RWOODS6', 'Summer Holiday', and 'Summer Night'. The cultivars that obtained US patents consisted of 18 cultivars (52.9%) with double flowers, 4 cultivars (11.8%) with semi-double flowers, and 12 cultivars (35.3%) with single flowers. The cultivars that obtained European new variety protection rights, consisted of 11 cultivars (34.3%) with double flowers, 12 cultivars (21.9%) with semi-double flowers, and 14 cultivars (43.8%) with single flowers. In the future, new cultivars of H. syriacus need to be developed in order to expand domestic distribution and export abroad. In addition, when developing new cultivars, it is required to develop cultivars with shorter branches for use in flower beds, borders, hedges, and pot planting.

The Melodic Structure of the Bulmosan Youngsanjae, Ongho-ge (불모산 영산재 범패 옹호게의 선율구조)

  • Choi, Heon
    • (The) Research of the performance art and culture
    • /
    • no.34
    • /
    • pp.383-421
    • /
    • 2017
  • Because the Jitsori and the Hotsori of the Beompae(the Korean Budhhist chant) has no meter and no Jangdan(a Rhythmic cycle of the Korean Music), so it is hard to analyze the melody of the Beompae. Also the melody of the Beompae is different from that of the other Korean traditional music, so studying of the Beompae has been out of the limelight of many scholars, studying the Korean music. But the melody of Beompae had been handed down for thousands of years in Korea, it and other Korean trditional music, had exchanged the impacts each other for a longtime. So I thinks that the Korean Beomapae have shared the similarity of the musical features with the other Korean traditional music. Because the Beompae of the Bulmosan Yeongsanjae on the Geongsangnamdo province has also no meters and no Jangdan, it is difficult to understand, too. But because the Onghoge of Bulmosan Yeongsanjae have a well-regulated melodic structure in comparison with the Beompae of the Seoul province, so called Geongjae Beompae, it seem to be easy to analyze its melody. So I will analyze the melody of Bulmosan Yeongsanjae Onghoge. This analyze should be contribute to investigate the rule of the melodic progress method on the convoluted Beompae melody. Onghoge has been sung on the procedure for Siryeon, Samsiniun(Goebuliun), Jojeonjeoman, Sinjungjakbeop. And the monk for the ritual has sung the chant first to purify the ritual place and to protect the soul. They has called the song, Onghoge a Jitsori at the Bulmosan Yeongsanjae preservation society of the Gyeongnam province. Commonly, there were Jitsori and Hotsori in the Beompae melody, and the melody of Jitsori is longer than that of the Hotsori. So, the melody of Onghoge is lengthened. In other word, the melody of the Onghoge show the lengthened and curved melodic feture of the Beompae very well. Hahn Manyeong, who had studied on the Beompae, Budhhist chant, said that the Hotsori has five letters in a phrase, and there were 4 phrases in a song. And he had insisted that the form of the song, Hotsori, is ABAB. I analyze the melody of the Onghoge by the Hahn's method. I will extract the Wonjeom(a primary tone of a skeletal melodic structure) from the melody of Onghoge, and in the progress of the Wonjeom of Onghoge melodies, I will arrange the repeat of the Wonjeom melody. It is a structural melody of Onghoge. The first phrase of Bulmosan Yeongsanjae Onghoge, 'Pal bu geum gang ho do ryang(八部金剛護道場)' have 4 structural melodies, the second phrase 'Gong sin sog bu bo cheon wang(空神速赴報天王)', the third phrase 'Sam gye je cheon ham le jip(三界諸天咸來集)', the firth phrase 'Yeo geum bul chal bo jeong sang(如今佛刹補禎祥)' have 2 structural melodies each. The structural melodies of Onghoge are 10 in total. And the structural melody of the Onghoge is formed the shape of 'Mi - La - do - La - Mi'. All of the Onghoge melodies is repeated 10 times by the melodic shape. The form of the Onghoge is not ABAB by Hahn, but is 10 times repeat of the shape.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF