• Title/Summary/Keyword: Guided Body

Search Result 146, Processing Time 0.028 seconds

Incidence of Fever Following Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration

  • Kim, Seo Yun;Lee, Jin woo;Park, Young Sik;Lee, Chang-Hoon;Lee, Sang-Min;Yim, Jae-Joon;Kim, Young Whan;Han, Sung Koo;Yoo, Chul-Gyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic method for mediastinal and hilar lymphadenopathy. This study aimed to investigate the incidence of fever following EBUS-TBNA. Methods: A total of 684 patients who underwent EBUS-TBNA from May 2010 to July 2012 at Seoul National University Hospital were retrospectively reviewed. The patients were evaluated for fever by a physician every 6-8 hours during the first 24 hours following EBUS-TBNA. Fever was defined as an increase in axillary body temperature over $37.8^{\circ}C$. Results: Fever after EBUS-TBNA developed in 110 of 552 patients (20%). The median onset time and duration of fever was 7 hours (range, 0.5-32 hours) after EBUS-TBNA and 7 hours (range, 1-52 hours), respectively, and the median peak body temperature was $38.3^{\circ}C$ (range, $137.8-39.9^{\circ}C$). In most patients, fever subsided within 24 hours; however, six cases (1.1%) developed fever lasting longer than 24 hours. Infectious complications developed in three cases (0.54%) (pneumonia, 2; mediastinal abscess, 1), and all three patients had diabetes mellitus. The number or location of sampled lymph nodes and necrosis of lymph node were not associated with fever after EBUS-TBNA. Multiple logistic regression analysis did not reveal any risk factors for developing fever after EBUS-TBNA. Conclusion: Fever is relatively common after EBUS-TBNA, but is transient in most patients. However, clinicians should be aware of the possibility of infectious complications among patients with diabetes mellitus.

Sizing Communications on Online Apparel Retail Websites - Focusing on Ready-to-Wear Women's Pants - (온라인 의류 쇼핑 사이트의 제품 사이즈 정보 실태 분석 - 여성용 바지를 중심으로 -)

  • Lee, Ah Lam;Kim, Hee Eun
    • Fashion & Textile Research Journal
    • /
    • v.24 no.1
    • /
    • pp.117-126
    • /
    • 2022
  • This study aims to analyze the sizing information of women's ready-to-wear pants as indicated on online retail websites and to suggest better sizing communication that can assist customers in making successful apparel size selections. We gathered size specifications and size reference information for basic straight pants from 34 online apparel retail websites. Although the Korean standard recommends labeling the body dimension-based sizing code and specification, most websites preferred to use various types of sizing codes. Body measurements were only used by a few websites, and garment dimension descriptions were the most common method to indicate product size. Many websites provided size reference information through customer review boards and fit model images, however, there was insufficient body size information to allow customers to infer the fit of their body type. When using the size guidance tools, the major data input points were stature and weight measurements. However, the waist measurements of pants sizes guided only by stature and weight values revealed inconsistent ease allowance for corresponding body size populations, especially in the overweight group. Based on our findings, we propose a more effective method of communicating the size information of pants online. We expect that this will contribute to the efficiency of online apparel product display and build a better shopping environment that satisfies both sellers and consumers.

A Moving Path Control of an Automatic Guided Vehicle Using Relative Distance Fingerprinting (상대거리 지문 정보를 이용한 무인이송차량의 주행 경로 제어)

  • Hong, Youn Sik;Kim, Da Jung;Hong, Sang Hyun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.10
    • /
    • pp.427-436
    • /
    • 2013
  • In this paper, a method of moving path control of an automatic guided vehicle in an indoor environment through recognition of marker images using vision sensors is presented. The existing AGV moving control system using infrared-ray sensors and landmarks have faced at two critical problems. Since there are many windows in a crematorium, they are going to let in too much sunlight in the main hall which is the moving area of AGVs. Sunlight affects the correct recognition of landmarks due to refraction and/or reflection of sunlight. The second one is that a crematorium has a narrow indoor environment compared to typical industrial fields. Particularly when an AVG changes its direction to enter the designated furnace the information provided by guided sensors cannot be utilized to estimate its location because the rotating space is too narrow to get them. To resolve the occurrences of such circumstances that cannot access sensing data in a WSN environment, a relative distance from marker to an AGV will be used as fingerprinting used for location estimation. Compared to the existing fingerprinting method which uses RSS, our proposed method may result in a higher reliable estimation of location. Our experimental results show that the proposed method proves the correctness and applicability. In addition, our proposed approach will be applied to the AGV system in the crematorium so that it can transport a dead body safely from the loading place to its rightful destination.

A Comparison of Appearance management Behaviors of middle school boys with girls in relation to the Perception of Body Size -Among girls and boys' middle school in Gwangju- (남.여 중학생의 체형인식에 따른 외모관리 항동 비교연구 -광주시내 남.여 공학 중학생을중심으로-)

  • Wee Eun-Hah
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.3 s.41
    • /
    • pp.119-131
    • /
    • 2006
  • The purpose of this study was to investigate the body size perception and appearance management behaviors of middle school boys and girls. Subjects of this study were 7 coeducational middle school boys and girls in Gwangju and 435 responses were collected from real body measurement and questionnaires. SPSS package 12.0(Kr) was used to analyze results. The results were summarized as follows: First, middle school boys and girls tended to perceive their bodies slimmer as well as obeser. It is recommended to give education for correct perception of their body sire. Second, the correlation of body size perception factor and appearance management behavior was Middle school boys and girls tended to manage their appearance using a diet rather than doing exercise in obesity distortion perception group(the group perceive obeser than real body size). It needs to be properly guided. Third, the appearance management behavior of slimness distortion perception group(the group perceive slimmer than real body size) and normal group was examined. While middle school boys did only exercise management, middle school girls did all but exercise management. Their education should be distinguished. Finally, while slimness distortion perception group did diet management in both middle school boys and girls, they tended not to manage body correction or exercise. A tendency to depend only on a diet in the group who should perceive their need of exercise should be corrected. In order to correct the distorted body perception and appearance management behavior of middle school boys and girls, it is recommended to educate a standard body size through home management education which is a regular curriculum, and at the same time to guide them to perceive their actual body size correct.

  • PDF

A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement (실리콘 광증폭기와 반응깊이 측정방법을 이용한 수술용 베타 영상/감마 프로브 가능성 연구)

  • Kwak, In-Suk;Kang, Han Gyu;Son, Jeong-Whan;Lee, Jae Sung;Hong, Seong Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Radiopharmaceutical agents for positron emission tomography (PET), such as $^{18}F$-FDG and $^{68}Ga$, have been used not only for whole-body PET imaging but also for intraoperative radionuclide-guided surgery due to their quantitative and sensitive imaging characteristics. Current intraoperative probes detect gamma or beta particles, but not both of them. Gamma probes have low sensitivities since a collimator has to be used to reduce backgrounds. Positron probes have a high tumor-to-background ratio, but they have a 1-2 mm depth limitation from the body surface. Most of current intraoperative probes produce only audible sounds proportional to count rates without providing tumor images. This research aims to detect both positrons and annihilation photons from $^{18}F$ using plastic scintillators and a GAGG scintillation crystal attached to silicon photomultiplier (SiPM). The depth-of-interaction (DOI) along the plastic scintillator can be used to obtain the 2-D images of tumors near the body surface. The front and rear part of the intraoperative probe consists of $4{\times}1$ plastic scintillators ($2.9{\times}2.0{\times}12.0mm^3$) for positron detection and a Ce:GAGG scintillation crystal ($12.0{\times}12.0{\times}9.0mm^3$) for annihilation photon detection, respectively. The DOI resolution of $4.4{\pm}1.6mm$ along the plastic scintillator was obtained by using the 3M enhanced specular reflector (ESR) with rectangular holes between the plastic scintillators, which showed the feasibility of a 2-D image pixel size of $2.9{\times}4.4mm^2$ (X-direction ${\times}$ Y-direction).

Transobturator Tape Under the Ultrasonographic Guidance -A Case Report- (초음파 유도하 경폐쇄공 띠의 제거 -증례 보고-)

  • Min, Kyoung-Dae;Hwang, Seok-Ha;Kang, Seung-Gu;Lee, Byung-Ill
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.118-122
    • /
    • 2012
  • Taking history and ultrasonography is important to detect foreign body which might be located in the soft tissue. We encountered a case of soft tissue foreign body (transobturator tape) in a patient who had been treated with the impression of adductor myositis resulting from vagina fistula. The foreign body was found through ultrasonographic examination and the patient's symptom was relieved after removal of the foreign body from the ultrasonography-guided operation. Clinicians should keep in mind the fact that foreign bodies may exist when the inflammation persists without appreciable cause and ultrasonography can be useful tool in case of small fibrous band not detected with magnetic resonance imaging due to inflammatory change of the surrounding tissues.

  • PDF

Development of Walking Assistive System using Body Weight Supporting and Path Planning Strategy (인체 자중 보상 및 로봇 경로계획법을 이용한 이동형 보행 재활 시스템 개발)

  • Yu, Seung-Nam;Shon, Woong-Hee;Suh, Seung-Whan;Lee, Sang-Ho;Han, Chang-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.939-947
    • /
    • 2010
  • With the rising numbers of elderly and disabled people, the demand for welfare services using a robotic system and not involving human effort is likewise increasing. This study deals with a mobile-robot system combined with a BWS (Body Weight Support) system for gait rehabilitation. The BWS system is designed via the kinematic analysis of the robot's body-lifting characteristics and of the walking guide system that controls the total rehabilitation system integrated in the mobile robot. This mobile platform is operated by utilizing the AGV (Autonomous Guided Vehicle) driving algorithm. Especially, the method that integrates geometric path tracking and obstacle avoidance for a nonholonomic mobile robot is applied so that the system can be operated in an area where the elderly users are expected to be situated, such as in a public hospital or a rehabilitation center. The mobile robot follows the path by moving through the turning radius supplied by the pure-pursuit method which is one of the existing geometric path-tracking methods. The effectiveness of the proposed method is verified through the real experiments those are conducted for path tracking with static- and dynamic-obstacle avoidance. Finally, through the EMG (Electromyography) signal measurement of the subject, the performance of the proposed system in a real operation condition is evaluated.

The Evaluation of a Health Coaching Program on Metabolic Syndrome Patients (대사증후군 대상자들의 건강코칭프로그램 평가)

  • Jo, Heui-Sug;Jung, Su-Mi;Lee, Hey-Jean
    • Korean Journal of Health Education and Promotion
    • /
    • v.29 no.1
    • /
    • pp.97-108
    • /
    • 2012
  • Objectives: We assessed the feasibility of health coaching for health coaching program on metabolic syndrome. Methods: We developed a 6 month health coaching program on metabolic Syndrome. We recruited people with metabolic syndrome according to modified NCEP-ATP III. The participants were 9 men over 30 years of age who had taken a health screening at general hospital. We collected data such as demographics, BMI, body fat, blood pressure, HDL-cholesterol blood sugar and triglyceride. The program was analyzed by using Wilcoxon signed rank test. Results: Participants showed significantly decreased BMI, weight, waist circumference, body fat after 6 month program. They talked the awareness about their own behavior. They changed into better for eating habits, physical activities, and self management. Their discipline increased and eating habits became regular. They were satisfied to this program and showed strong confidence about their own change. Conclusions: Coaching did not direct certain behavioral change but guided self awareness and practice. Health coaching program showed long maintained effect to participants. We suggested health coaching as a helpful individual program to intervene risky health behavior especially for metabolic Syndrome.

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Fabrication and Cell Culturing on Carbon Nanofibers/Nanoparticles Reinforced Membranes for Bone-Tissue Regeneration

  • Deng, Xu Liang;Yang, Xiao Ping
    • Carbon letters
    • /
    • v.13 no.3
    • /
    • pp.139-150
    • /
    • 2012
  • Poly-L-lactic acid (PLLA), PLLA/hydroxyapatite (HA), PLLA/multiwalled carbon nanotubes (MWNTs)/HA, PLLA/trifluoroethanol (TFE), PLLA/gelatin, and carbon nanofibers (CNFs)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) composite membranes (scaffolds) were fabricated by electrospinning and their morphologies, and mechanical properties were characterized for use in bone tissue regeneration/guided tissue regeneration. MWNTs and HA nanoparticles were well distributed in the membranes and the degradation characteristics were improved. PLLA/MWNTs/HA membranes enhanced the adhesion and proliferation of periodontal ligament cells (PDLCs) by 30% and inhibited the adhesion of gingival epithelial cells by 30%. Osteoblast-like MG-63 cells on the randomly fiber oriented PLLA/TEF membrane showed irregular forms, while the cells exhibited shuttle-like shapes on the parallel fiber oriented membrane. Classical supersaturated simulated body fluids were modified by $CO_2$ bubbling and applied to promote the biomineralization of the PLLA/gelatin membrane; this resulted in predictions of bone bonding bioactivity of the substrates. The ${\beta}$-TCP membranes exhibit good biocompatibility, have an effect on PDLC growth comparable to that of pure CNF membrane, and can be applied as scaffolds for bone tissue regeneration.