• 제목/요약/키워드: Guided

검색결과 3,891건 처리시간 0.027초

지시적 심상요법이 혈압과 맥박에 미치는 효과 - 간호대학생을 대상으로 - (The Effect of Guided Imagery on Blood Pressure and Pulse Rate - In Nursing Students -)

  • 최은옥;이동숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제5권2호
    • /
    • pp.31-39
    • /
    • 2003
  • The purpose of this study was to test the effect of guided imagery on blood pressure and pulse rate. The subjects were thirty-nine nursing students in I university located in Busan, Korea To enhance the effect of treatment, they were trained getting themselves absorbed in guided imagery on three different occasions before the study. Actually in the study, the subjects were given instruction in Mason's guided imagery for 19 minutes and 58 seconds. Blood pressure and pulse rate were measured before and after guided imagery application. The data were analyzed through paired t-test. The Results were as follows : 1) There was a significant decrease in systolic blood pressure after the use of guided imagery. 2) There was no significant decrease in diastolic blood pressure after the use of guided imagery. 3) There was a significant decrease in pulse rate after the use of guided imagery. These results indicate that guided imagery is a helpful technique for decreasing blood pressure and pulse rate, which are increased in stress condition.

  • PDF

Mode conversion and scattering analysis of guided waves at delaminations in laminated composite beams

  • Soleimanpour, Reza;Ng, Ching-Tai
    • Structural Monitoring and Maintenance
    • /
    • 제2권3호
    • /
    • pp.213-236
    • /
    • 2015
  • The paper presents an investigation into the mode conversion and scattering characteristics of guided waves at delaminations in laminated composite beams. A three-dimensional (3D) finite element (FE) model, which is experimentally verified using data measured by 3D scanning laser vibrometer, is used in the investigation. The study consists of two parts. The first part investigates the excitability of the fundamental anti-symmetric mode ($A_0$) of guided wave in laminated composite beams. It is found that there are some unique phenomena, which do not exist for guided waves in plate structures, make the analysis become more complicated. The phenomena are observed in numerical study using 3D FE simulations. In the second part, several delaminated composite beams are studied numerically to investigate the mode conversion and scattering characteristics of the $A_0$ guided wave at delaminations. Different sizes, locations and through-thickness locations of the delaminations are investigated in detail. The mode conversion and scattering phenomena of guided waves at the delaminations are studied by calculating reflection and transmission coefficients. The results show that the sizes, locations and through-thickness locations of the delaminations have significant effects on the scattering characteristics of guided waves at the delaminations. The results of this research would provide better understanding of guided waves propagation and scattering at the delaminations in the laminated composite beams, and improve the performance of guided wave damage detection methods.

해안방어 무기체계 효과분석 방법론: 사례연구를 중심으로 (A Case Study on Analysis Methodology of Costal Defence Weapon System)

  • 신상욱;최봉완;오천균;조한무
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.124-134
    • /
    • 2019
  • As the types of North Korea's provocation are diverse and unexpectable in the costal area, ROK navy needs to develop countermeasures, such as costal defence guided rockets. Recently ROK navy developed the PKX-B which is equipped with the new 130 mm guided rocket. The most popular rockets are LOGIR for short range targets, 130 mm guided rocket for middle range targets and Spike-NLOS for long range targets. As various guided rockets are developed, it is required to develop a guided rocket analysis model and it's analysis methodology. In addition, these guided rockets can be installed on any platforms; ground vehicle, aircraft and warship. The paper proposes systematic methodology to estimate the operational effectiveness of costal defence guided rockets. A case study exploiting the ARENA simulation model is explained to demonstrate the implementation of the proposed methodology.

Accuracy and Safety in Pedicle Screw Placement in the Thoracic and Lumbar Spines : Comparison Study between Conventional C-Arm Fluoroscopy and Navigation Coupled with O-Arm$^{(R)}$ Guided Methods

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.204-209
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the accuracy and clinical benefits of a navigation coupled with O-arm$^{(R)}$ system guided method in the thoracic and lumbar spines by comparing with a C-arm fluoroscopy-guided method. Methods : Under the navigation guidance, 106 pedicle screws inserted from T7 to S1 in 24 patients, and using the fluoroscopy guidance, 204 pedicle screws from T5 to S1 in 45 patients. The position of screws within the pedicle was classified into four groups, from grade 0 (no violation cortex) to 3 (more than 4 mm violation). The location of violated pedicle cortex was also assessed. Intra-operative parameters including time required for preparation of screwing procedure, times for screwing and the number of X-ray shot were assessed in each group. Results : Grade 0 was observed in 186 (91.2%) screws of the fluoroscopy-guided group, and 99 (93.4%) of the navigation-guided group. Mean time required for inserting a screw was 3.8 minutes in the fluoroscopy-guided group, and 4.5 minutes in the navigation-guided group. Mean time required for preparation of screw placement was 4 minutes in the fluoroscopy-guided group, and 19 minutes in the navigation-guided group. The fluoroscopy-guided group required mean 8.9 times of X-ray shot for each screw placement. Conclusion : The screw placement under the navigation-guidance coupled with O-arm$^{(R)}$ system appears to be more accurate and safer than that under the fluoroscopy guidance, although the preparation and screwing time for the navigation-guided surgery is longer than that for the fluoroscopy-guided surgery.

유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성 (Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy)

  • 최미선;송종남
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.201-206
    • /
    • 2016
  • 유방암에 관한 사회적인 관심이 증가되고 있는 가운데 진단의 가장 기본이 되는 검사는 유방 X선 촬영과 유방 초음파 검사이다. 특히 유방 미세석회화는 조직학적 진단을 필요로 하며 유방 미세석회화 조직검사를 시행하고 있다. 이에 미세석회화 진단에 기본이 되는 X선 유도 하 조직검사(needle localized open biopsy)와 초음파 유도 하 조직검사(sono guided core needle biopsy)를 분석하여 평가하고자 한다. 유방 미세석회화를 주소로 내원한 환자에서 확대 촬영을 시행한 241예를 대상으로 X선 유도 하 조직검사(needle localized open biopsy)와 초음파 유도 하 조직검사(sono guided core needle biopsy)의 연령대 별 분포와 병소의 위치를 분석하고 확대촬영 시행 후 이루어진 검사를 분류해서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 빈도를 분석하고 악성과 양성의 결과를 확인 하였다. 그 결과 X선 유도 하 조직검사(needle localized open biopsy)가 64예(26.6%)로 초음파 유도 하 조직검사(sono guided core needle biopsy) 12예(4.9%)에 비해 5.4배 높은 것으로 나타났다. 초음파 장비의 발달과 입체정위 흡입법(stereotactic vacuum-assisted biopsy)등의 발달로 미세석회화의 조직학적 진단방법이 다양해지고 있지만, 각각 검사의 특성과 한계점을 고려해 볼 때 X선 유도 하 조직검사(needle localized open biopsy)가 유방 미세석회화 병변에서는 정확한 조직학적 진단을 제공한다고 사료된다.

A Method of Coupling Expected Patch Log Likelihood and Guided Filtering for Image De-noising

  • Wang, Shunfeng;Xie, Jiacen;Zheng, Yuhui;Wang, Jin;Jiang, Tao
    • Journal of Information Processing Systems
    • /
    • 제14권2호
    • /
    • pp.552-562
    • /
    • 2018
  • With the advent of the information society, image restoration technology has aroused considerable interest. Guided image filtering is more effective in suppressing noise in homogeneous regions, but its edge-preserving property is poor. As such, the critical part of guided filtering lies in the selection of the guided image. The result of the Expected Patch Log Likelihood (EPLL) method maintains a good structure, but it is easy to produce the ladder effect in homogeneous areas. According to the complementarity of EPLL with guided filtering, we propose a method of coupling EPLL and guided filtering for image de-noising. The EPLL model is adopted to construct the guided image for the guided filtering, which can provide better structural information for the guided filtering. Meanwhile, with the secondary smoothing of guided image filtering in image homogenization areas, we can improve the noise suppression effect in those areas while reducing the ladder effect brought about by the EPLL. The experimental results show that it not only retains the excellent performance of EPLL, but also produces better visual effects and a higher peak signal-to-noise ratio by adopting the proposed method.

Utility of Radial Probe Endobronchial Ultrasound-Guided Transbronchial Lung Biopsy in Diffuse Lung Lesions

  • Kim, Eun Jin;Kim, Kyung Chan
    • Tuberculosis and Respiratory Diseases
    • /
    • 제82권3호
    • /
    • pp.201-210
    • /
    • 2019
  • Background: Radial probe endobronchial ultrasound (R-EBUS) is widely used for diagnosing peripheral pulmonary lesions. However, the utility of R-EBUS-guided transbronchial lung biopsy (TBLB) for diffuse lung lesions (DLLs) remains unknown. We designed this study to evaluate the utility of R-EBUS-guided TBLB in DLLs. Methods: This retrospective study enrolled patients admitted from January 2016 to November 2017 who underwent TBLB for DLLs. The R-EBUS-guided TBLB and blind TBLB groups were compared. DLL was defined as any lung disorder that involved more than one segment of the lung. In both the groups, fluoroscopy and guided sheath were not used during TBLB. Results: A total of 127 patients underwent TBLB for DLLs (67 patients in the R-EBUS-guided TBLB group and 60 in the blind TBLB group). There were no differences in age, sex, and comorbid illnesses between the two groups. Furthermore, there was no difference in the TBLB diagnostic yield of the two groups (p=0.660) although more samples were collected from the R-EBUS-guided TBLB group (p=0.003). Procedure time was significantly longer in the R-EBUS-guided TBLB group than in the blind TBLB group (p<0.001). Thus, incidence of pneumothorax was significantly lower in the R-EBUS-guided TBLB group than in the blind TBLB group (p=0.032). Conclusion: Diagnostic yield in DLLs did not differ between the R-EBUS-guided TBLB and blind TBLB groups. Findings show that R-EBUS-guided TBLB in DLLs may reduce risk of pneumothorax.

유도무기의 신뢰성 향상을 위한 비행환경 모사시험 방안 연구 (Flight Environment Simulation Test for Reliability Improvement of Precise Guided Missile)

  • 최승혁
    • 한국정밀공학회지
    • /
    • 제33권10호
    • /
    • pp.781-787
    • /
    • 2016
  • We introduce FEST (Flight Environment Simulation Test) procedures for precise guided missiles to reliably improve systems. Flight vibration specification was established based on power spectral density curves calculated from flight test data of a high speed precise guided missile. A FEST pre-profile was developed according to flight vibration specification and delivered to a precise guided missile assembly. Vibration responses were measured by installing accelerometers on electronic components vulnerable to dynamic forces. The FEST profile was adjusted by comparing the vibration responses and the flight vibration specification. Subsequently, the FEST profile was repeatedly modified through trial and error, because the responses were similar to the flight environment. The modified FEST profile enabled performance testing of assembled precise guided missiles under simulated flight conditions on the ground, where unexpected errors could be corrected before the flight tests, leading to cost and risk reduction in the development of the precise guided missile system.

유도파 기반 장거리 파이프라인 검사를 위한 모니터링 센서의 위치결정 (Determinating Sensor Location for Guided-Wave-Based Long Range Pipeline Inspection)

  • 나원배;류연선;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.232-239
    • /
    • 2006
  • Guided wave techniques have been used for pipeline inspection because of the long range inspection capability of guided waves. One of main concerns of these technique is how ones decide the axial interval of sensors when they are utilized for pipeline inspection. This question is related to the characteristic of cylindrical guided wave propagation, especially wave attenuation. Thus, attenuation of fundamental longitudinal guided wave propagating liquid-filled steel pipes is numerically investigated in the paper. Several liquids such as water, diesel oil, castor oil etc. are considered for the filing materials in the pipes. Sink is considered for numerical models for abandoning standing wave modes; hence, the attenuation dispersion curves become much simpler. Those attenuation calculations can be utilized for guided-wave-based nondestructive testing of pipelines when one inspects pipelines, using monitoring sensors, which are installed outside pipes.

  • PDF

유도 초음파 이용 결함 진단을 위한 정합추적 기법 (Matching Pursuit Approach for Guided Wave-based Damage Inspection)

  • 홍진철;선경호;김윤영
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.382-387
    • /
    • 2005
  • For successful guided-wave damage inspection, the appropriate signal processing of measured wave signals is very important. The objective of this paper is to introduce an efficient signal processing technique especially suitable for the guided-waves used for damage detection. The key idea of this technique is to model guided-waves by chirp functions of special form considering the dispersion phenomenon. To determine the parameter of the chirp functions simulating guided-waves, the matching pursuit algorithm is employed. The damage information in waveguides can be extracted by pulse-characterizing parameters. The effectiveness of present method is checked with the guided wave-based damage inspection.