• 제목/요약/키워드: Guide wire

검색결과 83건 처리시간 0.02초

고속전철용 집전시스템의 동적해석 (Dynamic Analysis of Current Collection System in High Speed Train)

  • 최연선;최진민;경진호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1995년도 추계학술대회논문집; 한국종합전시장, 24 Nov. 1995
    • /
    • pp.142-147
    • /
    • 1995
  • Dynamic characteristics of current collection system is one of the major factors which decide the performance of high speed train. To find good design parameters of the current collection system design guide is prepared through the engineering analysis in this study. The analysis starts from the statics of catenary system which results in the sinusoidal variation of stiffness, which is inherently nonlinear Mathieu equation. Simple physical models of rigid trolley wire and Mathieu equation are considered. To simulate the dynamic response of current collection system, numerical integration based on central difference method and modal analysis are presented. The calculated results of central difference method show superior to those of Euler based algorithm.

  • PDF

요골동맥을 통한 관상동맥촬영 중 진단된 편위된 우측쇄골하동맥 1예 (A Case of Aberrant Right Subclavian Artery (Arteria Lusoria) with Chest Tightness and Coughing)

  • 한승희;김수영;박혜경;박종성
    • Journal of Yeungnam Medical Science
    • /
    • 제29권1호
    • /
    • pp.61-64
    • /
    • 2012
  • The left aortic arch with an aberrant right subclavian artery, or arteria lusoria, is the most common aortic arch anomaly, occurring in 0.5-2.5% of individuals. In such cases, the angular course of the arteria lusoria to the ascending aorta imposes difficulty in passing a guide wire to the ascending aorta during right transradial catheterization. Here, the case of a 53-year-old woman with intermittent chest tightness and coughing is reported. Aberrant right subclavian artery (arteria lusoria) was diagnosed via aortogram during right transradial coronary angiography. Compression of the esophagus and trachea by the aberrant right subclavian artery was demonstrated by chest computed tomography (CT).

  • PDF

송전선로 주위의 도체에 미치는 유도장해 해석 (Analysis of the inductive interference on the conductor around power system)

  • 최세용;나완수;최명준;이세희;김동훈;박일한;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1034-1037
    • /
    • 1999
  • In this paper, we analyze the inductive interference in conductive material around power transmission line. To compute induced eddy currents as well as electromagnetic fields, finite element method(FEM) is used for numerical calculation. The characteristics of conductive material such as gas pipeline, overhead guide wires, conducting earth and so on are taken account of FEM analysis. This research also shows that mitigation wire reduces amount of eddy current in buried gas pipe line.

  • PDF

컴퓨터비전을 이용한 지중관로의 직경 측정 (Measurement of the Underpipe Diameter by using Computer Vision)

  • 김기범;조성만;주원종
    • 한국생산제조학회지
    • /
    • 제26권2호
    • /
    • pp.251-256
    • /
    • 2017
  • This study developed an image processing system for detecting damages on underground spiral PVC pipes. The detection method is simple-identifying damaged areas by measuring circularity along the pipeline. This uses the assumption that damage parts will not make a circular shape. Conventional devices check the circular shape of the pipe along the pipeline by measuring the angles between 6 spring-connected legs on the device. The conventional device, however, requires the insertion of 3 different wires (electrical, communication, and camera lines) along with a guide wire for pulling the device. The developed system presented here has simplified this system, requiring only a camera line while maintaining reasonable accuracy in damage detection.

에어컨 실외기에서의 유동소음 (Flow Noise in the Outdoor Unit of an Air-conditioner)

  • 이승배;이재환;김휘중;최진규;진성훈;박윤서
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.594-601
    • /
    • 1997
  • Propeller fans are commonly equipped in outdoor units of air-conditioners to provide effective cooling in a dried heat exchanger. A new design technique was developed to satisfy requirements of aerodynamic and aeroacoustic performance, which employs the intersection method of two cylinders for mean camber line. Three proto-types of propeller fan including Palm-Shaped, Highly-Swept(PSHS) fan (proto 3)were not only to provide low lift forces for dipole sound, but also to reduce the organized tip vortices interacting with the fan guide causing narrow-banded rotating instabilities. Cross-correlation technique was applied to study flow noise source characteristics for three proto-type fans designed. The cross-correlations between a microphone at far field and a hot-wire sensor at near field show that flows near hub region of proto 3 fan are less organized and the flow structures especially at high flow rate coefficients for proto 3 fan are less correlated with noise generated than other proto-types fans.

  • PDF

정상교합자의 치열궁 설측형태에 관한 연구 (A STUDY ON THE LINGUAL MORPHOLOGY OF THE DENTAL ARCH IN NORMAL OCCLUSION)

  • 전경민;남동석
    • 대한치과교정학회지
    • /
    • 제15권2호
    • /
    • pp.303-312
    • /
    • 1985
  • This study was designed to get the knowledge of the structural characteristics of the lingual dental arch shapes of Koreans. The subjects consisted of 107 normal occlusions. The lingual structure which was divided into two groups, anterior and posterior part, was measured and analyzed. 33 pairs of the 107 samples were used to test the derived results. The findings of this study were as follows: 1. The mathmatical functions of the 12 curves which showed good fitting to the upper and lower anterior lingual arch were derived and flawed to the same scale using the computer graphics. 2. The results of the test showed a reasonable degree of accuracy to all of the 33 random samples. 3. The average degrees of posterior flexions were obtained and could be used as a initial guide at the wire-bending.

  • PDF

미세 부품 조작을 위한 탄성힌지 기반 압전소자 구동형 초정밀 머니플레이션 시스템 (A Piezo-driven Fine Manipulation System Based on Flexure Hinges for Manipulating Micro Parts)

  • 최기봉;이재종;김기홍;고국원
    • 제어로봇시스템학회논문지
    • /
    • 제15권9호
    • /
    • pp.881-886
    • /
    • 2009
  • This paper presents a manipulation system consisting of a coarse/fine XY positioning system and an out-of-plane manipulator. The object of the system is to conduct tine positioning and manipulation of micro parts. The fine stage and the out-of-plane manipulator have compliant mechanisms with flexure hinges, which are driven by stack-type piezoelectric elements. In the fine stage, the compliant mechanism plays the roles of motion guide and displacement amplification. The out-of-plane manipulator contains three piezo-driven compliant mechanisms for large working range and fine resolution. For large displacement, the compliant mechanism is implemented by a two-step displacement amplification mechanism. The compliant mechanisms are manufactured by wire electro-discharge machining for flexure hinges. Experiments demonstrate that the developed system is applicable to a fine positioning and fine manipulation of micro parts.

열연 다운코일러 모니터링 시스템 개발 (Development of Monitoring System for Guide Roller in Wire Rolling Proces)

  • 손붕호;임은섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2564-2566
    • /
    • 2001
  • The reliability of EIC(Electricity, Instrumentation and Computer) systems in hot rolling mill is very important in order to maintain stable production. Signals obtained from sensors and control system should be analyzed to monitor the condition of down coiler in hot rolling mill. We develop a monitoring system of down coiler which is composed of three parts : (1) data acquisition and MMI, (2) signal processing and analyzing, and (3) automatic data saving. Also it is designed to enable to inform users the abnormal conditions of down coiler. This developed system is expected to make it possible to reduce long downtime, secure high facility precision, and maintain high control levels.

  • PDF

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

ETA를 통한 연구실험실 콘센트회로의 전기재해 분석 (Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA)

  • 김두현;김성철;박종영;김상철
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.