• 제목/요약/키워드: Guide wire

Search Result 83, Processing Time 0.027 seconds

Digital subtraction angiography(DSA) of hepatic artery using selective catheterization technique in beagle dogs (비글견에서 선택적 카테터 삽관법을 이용한 간동맥의 디지털 감산 혈관조영술)

  • Chang, Dong-woo;Yun, Young-min;Kim, Bong-kyeong;Lee, Young-won;Yoon, Jung-hee;Kweon, Oh-kyeong;Seong, Je-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.665-671
    • /
    • 1999
  • The aim of this study was to establish selective hepatic artery catheterization technique through percutaneous femoral artery puncture and to offer digital subtraction angiography (DSA) of hepatic artery in beagle dogs. Percutaneous femoral artery puncture was performed with Sheldinger's method. Microferret$^{TM}$-18 Infusion catheter(William, Cook, Europe) was introduced into abdominal aorta. Then, under fluoroscopy, iopamidol 370(Bracco, Italy) was injected to identify celiac artery and 'J' shaped guide wire was introduced into celiac artery. Catheter could be introduced into celiac artery through guide wire. In this manner, catheter was located at the insertion of hepatic artery and DSA was performed. In DSA of beagle dogs, hepatic artery which was divided into lateral branch, right-medial branch, right-lateral branch of hepatic artery, cystic artery and gastroduodenal artery was opacified without superimposition of any other body structure and so was the parenchyme of liver afterward. In autopsy angiographic finding of resected liver, cystic artery, caudate branch, lateral branch, right-medial branch, right-lateral branch and quadrate branch of hepatic artery were identified. It was concluded that selective hepatic artery catheterization technique was a minimally invasive method that facillitated the approach of hepatic artery and DSA was an excellent tool to visualize the vessle of liver in dogs.

  • PDF

Development of Transportational Guide System for Joining Small Wire with Gabion (개비온 끝단 소둔선 결합용 이송 가이드 장치 개발 연구)

  • Lee, Jong kil;Kin, Jong-Tae
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.211-225
    • /
    • 2006
  • Gabion can be used for the purpose of preventing overflow of river and side loss of road. However the manufacturing process of the gabion is manually controlled especially to the joining process at the terminal part of gabion with small diameter wire. In this paper automatic feeding guide system was designed and fabricated to make automation. The fabricated system was tested in the factory level. Pneumatic system was considered as the main idea of the feeding system. 3/2-way and 5/2-way manual control valve, eight double-acting cylinders were used. The system took 46.48 seconds during a cycle. Additional environmental noise and vibration were not detected when the machine operated at the working area. Based on the theoretical simulation and actual test the fabricated system was well controlled. The system was applied to the patent in 2006.

Wire-guided Localization Biopsy to Determine Surgical Margin Status in Patients with Non-palpable Suspicious Breast Lesions

  • Dogan, Lutfi;Gulcelik, M. Ali;Yuksel, Murat;Uyar, Osman;Reis, Erhan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.4989-4992
    • /
    • 2012
  • Purpose: Guide-wire localization (GWL) has been a standard technique for many years. Excision of nonpalpable malignant breast lesions with clear surgical margins reduces the risk of undergoing re-excision. The objective of the present study was to evaluate the efficacy of GWL biopsy for assessing surgical margins. Methods: This retrospective study concerned 53 patients who underwent GWL biopsy for non-palpable breast lesions and breast carcinoma diagnosed by histological examination. Age of the patients, tumour size, radiographic findings, breast density specifications, specimen volumes, menopausal status and family history of the patients and surgical margin status were recorded. Results: Median age was 53.3 years, median tumour size was 1.5 cm and median specimen volume was $71.5cm^3$. In fifteen patients (28%) DCIS and in 38 patients (72%) invasive ductal carcinoma was diagnosed. There was positive surgical margins in twenty eight (52.8%) patients. The median distance to the nearest surgical margin was 7.2 mm in clear surgical margins. Younger age and denser breast specifications were found as statistically significant factors for surgical margin status. Median age of the patients who had positive margins was 49.4 years where it was 56.9 years in the patients with negative margins (p=0.04). 79% of the patients with positive margins had type 3-4 pattern breast density according to BIRADS classification as compared to 48% in the patients who had negative margins (p=0.03). Some 38 patients who had positive or close surgical margins received re-excision (72%). Conclusion: Positive margin rates may be higher because of inherent biological differences and diffuse growth patterns in younger patients. There are also technical difficulties that are relevant to denser fibroglandular tissue in placing hooked wire. High re-excision rates must be taken into consideration while performing GWL biopsy in non-palpable breast lesions.

Development of Design Method on High Pressure Vessel of 100L-700MPa Grade (100L-700MPa급 초고압 용기 설계 기술 개발)

  • Park, Bo-Gyu;Lee, Ho-Joon;Lee, In-Jun;Park, Si-Woo;Cho, Kyu-Shang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.8
    • /
    • pp.67-73
    • /
    • 2019
  • An ultra-high pressure treatment device is a device used for increasing the shelf life of food by sterilizing it by applying hydrostatic pressure to solid or liquid food. The ultrahigh pressure treatment system developed in this study is a pressure vessel with a processing capacity of 100 L and a maximum pressure of 700 MPa. Pressure vessels for ultrahigh-pressure processing equipment are manufactured using wire-winding techniques. The design formula for making ultra-high pressure vessels with wire windings is given in ASME Section VIII - Division 3. In this study, the ratio of the cylinder to the winding area that can be applied in a wire-winding application was analyzed using a finite element analysis. Furthermore, the relationship between the variation of the residual stress in the vessel and the ratio of the winding area due to the variation of the winding tension was analyzed, and a design guide applicable to the actual product design was developed. Finally, the design equation was modified by presenting the coefficients to correct the difference between the finite element analysis and the design equation.

Treatment of Anterior Glenoid Rim Fracture with Comminuted Fragment Using Arthroscopic Reduction and AO Headless Compression Screw Fixation - A Case Report - (관절경하 AO 무두 압박 나사를 이용한 견갑골 전방 관절와 분쇄 골절의 치료 - 증례 보고 -)

  • Kim, Hyung-Sik;Koh, Il-Hyun;Kim, Sung-Guk;Chun, Yong-Min;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.94-98
    • /
    • 2011
  • Purpose: We present a case of anterior glenoid rim comminuted fracture that was treated with arthroscopic reduction and an AO headless compression screw (HCS) fixation. Materials and Methods: A 31-year old man complained of left shoulder pain after falling down on stairs. The anterior glenoid comminuted fragments were arthroscopically reduced. Fixation with an AO HCS was done after placement of 1.1 mm Kirschner wire as a guide pin through a standard cannulated anterosuperior portal. Results: Twelve months after the operation, union of the fracture was achieved and the range of motion was fully recovered. He did not complain of any discomfort during his activities of daily living. Conclusion: An AO HCS had various screw sizes and this was good for fixation of a small glenoid fracture and a long drill bit and screw driver were useful for fixation of deep seated glenoid fracture. A short guide wire could be replaced by a 1.1 mm K-wire. An AO HCS was useful for fixation of an anterior glenoid rim comminuted fracture.

Effect of the Swirl Number of Spinner on the Exhaust Air of the Gun Type Burner (건타입 버너의 토출공기에 대한 선회기의 스월 수 영향)

  • Ko, Dong Guk;Yoon, Suck Ju
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.70-75
    • /
    • 2015
  • Swirl flow in the gun type burner has an impact on the stabilization of the flame, improvement of the combustion efficiency. The swirl flow is created by the spinner which is inside the airtube that guide the combustion air. Gun type burner has generally the inner devices composed electronic spark plug, injection nozzle, combustion device adaptor, and spinner. These inner components change the air flow behavior passing through airtube. So, this study conducted the measurement using by hot-wire anemometer and analyzed effect of the swirl number of spinner on the exhaust air of gun type burner. Turbulence characteristics come up in this study was mean velocity, turbulence intensity, kinetic energy, shear stress and flattness factor of the air flow with the change of the distance of axial direction and tangential direction from the exit of the airtube.

Flexibile Analysis of Coronary Stents due to Loading Directions (하중 방향에 따른 관상동맥용 스텐트의 유연성 해석)

  • 조승관;조은정;김한성
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.331-334
    • /
    • 2004
  • In clinical use, coronary stents keep coronary arteries open after expansion with a balloon catheter and prevent the expanded artery from collapsing. Coronary stents are positioned in artery by catheter with a balloon along a guide wire to the lesion site. Flexibility is one of important ability for delivery. In this paper, Palmaz-Schatz stent and Tenax complete stent were selected because these are the most representative of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Standard code. The present study estimated the flexibility of coronary stents due to loading directions. Moreover the present paper suggests a numerical method to test the flexibility of stents. In conclusion this paper shows how the finite element analysis can be effectively organized in the stent development.

  • PDF

Renal Subcapsular Hematoma after Percutaneous Transfemoral Angiography

  • Yi, Jin-Seok;Lee, Hyung-Jin;Lee, Hong-Jae;Yang, Ji-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.96-98
    • /
    • 2014
  • Vascular complications after percutaneous angiography include hematoma, pseudoaneurysm, arteriovenous fistula, thromboembolism, arterial laceration and infection. Hematomas may occur in the groin, thigh, retroperitoneal, intraperitoneal, or abdominal wall. A 54-year-old female underwent percutaneous transfemoral angiography for the evaluation of cerebral aneurysm. Renal subcapsular hematoma developed 3 hours after the procedure. Renal subcapsular hematoma after percutaneous angiography is very rare. We investigated the possible causes of renal subcapsular hematoma. To avoid this rare complication, we need to perform guide-wire passage carefully from the beginning of the procedure under full visual monitoring.

CFD ANALYSIS AND EXPERIMENT OF EXHAUST MANIVERTER OF GASOLINE ENGINE (가솔린 엔진용 배기매니버터 유동특성 해석 및 시험에 관한 연구)

  • Eom, Y.S.;Park, N.S.;Shin, C.G.;Lee, J.J.;Yi, G.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.468-472
    • /
    • 2010
  • To develop the Exhaust Maniverter(Manifold and converter) it needs to consider flow characteristics related to durability and performance of the catalyst, manufacturability, etc. This paper presents the analysis results regarding to flow characteristics such as flow uniformity, tangential speed, O2 sensor sensitivity and CHT (conjugate heat transfer) for the LCF(Low Cycle Fatigue) for gasoline 2.0 liter engine. The results are satisfactorily corresponded to the general criteria. Also skin temperature and pressure drop wire measured at the Engine Bench. These results can be useful for the design guide for Exhaust Maniverter.

  • PDF

A Study on Seam Tracking for Fillet Welding using High Speed Rotating Arc Sensor (고속회전 아크센서를 이용한 필렛 용접선 추적에 관한 연구)

  • Lee, Won-Ki;Lee, Gun-You;Oh, Myung-Seok;Kim, Sang-Bong
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.917-922
    • /
    • 2003
  • In this paper, a high speed rotating arc sensor for automatic fillet welding is introduced. In order to track the welding seam, The high speed rotating arc sensor is used. The welding tip of a high speed rotating arc sensor rotates about 3000 rpm using DC motor. The rotating torch is driven by gear between welding torch body and wire guide. The welding current is measured by using the current sensor and rot at ing position sensor. To realize the welding seam tracking algorithm with accuracy, a software filter algorithm using the moving average method is applied to the measured welding current in the microprocessor. The welding mobile robot with two wheels and two sliders is developed for fillet welding. The welding mobile robot can control its traveling direction and turn itself around the corner. The effectiveness is proven through the experimental results conducted with varied fillet tracking patterns.

  • PDF