• Title/Summary/Keyword: Guide tube

Search Result 127, Processing Time 0.023 seconds

Radial Probe Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Peripheral Pulmonary Lesions without Fluoroscopy

  • Hong, Kyung Soo;Ahn, Heeyun;Lee, Kwan Ho;Chung, Jin Hong;Shin, Kyeong-Cheol;Jin, Hyun Jung;Jang, Jong Geol;Lee, Seok Soo;Jang, Min Hye;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.4
    • /
    • pp.282-290
    • /
    • 2021
  • Background: Radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB) has improved the diagnostic yield of bronchoscopic biopsy of peripheral pulmonary lesions (PPLs). The diagnostic yield and complications of RP-EBUS-TBLB for PPLs vary depending on the technique, such as using a guide sheath (GS) or fluoroscopy. In this study, we investigated the utility of RP-EBUS-TBLB using a GS without fluoroscopy for diagnosing PPLs. Methods: We retrospectively reviewed data from 607 patients who underwent RP-EBUS of PPLs from January 2019 to July 2020. TBLB was performed using RP-EBUS with a GS without fluoroscopy. The diagnostic yield and complications were assessed. Multivariable logistic regression analyses were used to identify factors affecting the diagnostic yields. Results: The overall diagnostic accuracy was 76.1% (462/607). In multivariable analyses, the size of the lesion (≥20 mm; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.27-3.33; p=0.003), positive bronchus sign in chest computed tomography (OR, 2.30; 95% CI, 1.40-3.78; p=0.001), a solid lesion (OR, 2.40; 95% CI, 1.31-4.41; p=0.005), and an EBUS image with the probe within the lesion (OR, 6.98; 95% CI, 4.38-11.12; p<0.001) were associated with diagnostic success. Pneumothorax occurred in 2.0% (12/607) of cases and chest tube insertion was required in 0.5% (3/607) of patients. Conclusion: RP-EBUS-TBLB using a GS without fluoroscopy is a highly accurate diagnostic method in diagnosing PPLs that does not involve radiation exposure and has acceptable complication rates.

A Study of Separation Mechanism in Ball Type Separated Bolt (볼타입 분리볼트의 분리현상 연구)

  • Lee, Yeung-Jo;Koo, Song-Hoe;Jang, Hong-Bin;Lee, Bang-Eop
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.2
    • /
    • pp.62-67
    • /
    • 2011
  • Launching tube is a kind of case to protect the guided weapons from external environments and conducted as a guide when they are fired. The guided weapons have been firmly kept at the launching tube and transferred, and would be separated at the required time when they are fired To meet the aim, it has been used explosive bolts which are reliable and efficient mechanical fastening devices having the special feature of a built-in release. The disadvantage of explosive bolt lies in that it is based on the high explosive effect of a pyrotechnic charge. When the explosive bolt is ignited, there are some bad effects; a flame, fragments and pyro-shock. Because of these bad effects there are many restriction to use bolt as joining devices to precision guided weapons. To solve these problems, the aim of the present work is to invent the ball-type separation bolt which is a pyrotechnically releasable mechanical linking device for two mechanical elements that does not suffer from such drawbacks. A standard pressure cartridge can moreover be easily integrated inside the device according to the present work and this with no modification to its structure. The present work was represented quantitatively the margin of separation safety and analysed separation mechanism in ball type separating bolt to perform the dynamic separation test.

Comparison between Transthoracic Fine Needle Aspiration Cytology and Gun Biopsy of Pulmonary Mass (폐종괴에 대한 경피적 세침흡인세포검사와 자동총부착 침생검의 비교)

  • Nam, Eun-Sook;Kim, Duck-Hwan;Shin, Hyung-Sik
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1998
  • To compare the diagnostic yields and complication rates of transthoracic fine needle aspiration cytology(FNAC) and gun biopsy in the diagnosis of pulmonary mass, a retrospective review was performed in 125 cases. Under the fluoroscopic guide, FNAC was performed by 20G Chiba needle in 91 cases, core biopsy was done by 18.5 G vaccum needle attached with automated biopsy gun in 74 cases and both procedures were done together in 37 cases. Overall sensitivity was 88.4% in FNAC and 87.5% in gun biopsy. For malignant pulmonary tumors, correct type correlation with final diagnosis was obtained in 33(76.7%) out of 43 cases by FNAC and 30(75.0%) out of 40 cases by gun biopsy. For benign pulmonary lesions, there were correct type correlation in 14(35.0%) out of 40 cases by FNAC and 14(53.8%) out of 26 cases by gun biopsy. The complication was pneumothorax and hemoptysis. Pneumothorax occured in 11.1% of FNAC, 10.9% of gun biopsy and 10.9% of both technique, among which chest tube drainages were necessary in one patient by gun biopsy and in three patients by both technique. Although no significant difference of diagnositc accuracy and complication rate was found between FNAC and gun biopsy, gun biopsy was more helpful in the diagnosis of pulmonary benign lesions than FNAC.

  • PDF

Analysis of Horizontal Neutron Reflectometer for Nanointerfaces Using McStas (나노 계면분석을 위한 수평형 중성자 반사율 측정장치의 McStas 시뮬레이션 분석)

  • Kwon, Oh-Sun;Shin, Kwan-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.1
    • /
    • pp.7-14
    • /
    • 2007
  • A new horizontal neutron reflectometer has been designed and now under construction at the HANARO, 30 MW research reactor, in Daejon, Korea. We performed simulations of neutron ray-tracing to evaluate the performance of all of the optical components of the instrument with a Monte Carlo technique using McStas. The feasible wavelength of the incident neutron beam is $2.5{\AA}$. It produces a q-range up to $0.126{\AA}^{-1}$ with a supermirror as a deflector. Our studies showed improvement of the performance of the guide tube and monochromators. Although the performance is limited in q-range, it promises to be the first reflectometer in Korea for the study of free surfaces, which is currently in demand.

Mechanical Performance Evaluation of a Top End Piece for Dual Cooled Fuels (이중냉각 핵연료 상단고정체의 기계적 성능평가)

  • Kim, Jae-Yong;Yoon, Kyung-Ho;Kim, Hyung-Kyu;Choi, Woo-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.417-424
    • /
    • 2011
  • A fuel assembly consists of five major components, i.e., a top end piece (TEP), a bottom end piece (BEP), spacer grids (SGs), guide tubes (GTs) and an instrumentation tube (IT); in addition, it also includes fuel rods (FRs). The TEP/BEP should satisfy stress intensity limits according to the conditions A and B of ASME, Section III, Division 1-Subsection NB. In a dual-cooled fuel assembly, the array and position of fuel rods are different from those in a conventional PWR fuel assembly; these changes are necessary for achieving power uprating. The flow plates of the TEP and BEP have to be modified accordingly. The pattern and shape of the flow holes were newly designed. To verify the strength compatibility, the Tresca stress limit according to the ASME code was investigated in the case of an axial load of 22.241 kN. In this paper, the stress linearization procedure for strength evaluation of a newly designed TEP is presented.

Reliability Investigation of a Pump-Turbine System at Various Operating Conditions (운전조건에 따른 펌프 터빈 시스템의 안정성 연구)

  • Chen, Chengcheng;Singh, Patrick Mark;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.46-52
    • /
    • 2015
  • Pump-turbine system is widely used by the hydropower industry for stabilizing the electrical grid in the vast growing economy of most developed countries. This study only investigates the Fluid-structure Interaction (FSI) analysis of the pump-turbine system at various operating conditions. The FSI analysis can show how reliable each component of the system is by providing the engineer with a better understanding of high stress and deformation points, which could reduce the lifespan of the pump-turbine. Pump-turbine components are categorized in two parts, pressurized static parts and movable stressed parts. The fixed parts include the spiral casing, top and bottom cover, stay vane and draft tube. The movable parts include guide vanes and impeller blades. Fine hexahedral numerical grids were used for CFD calculation and fine tetrahedral grids were used for structural analysis with imported load solution mapping greater than 90 %. The maximum equivalent stress are much smaller than the material yield stress, and the maximum equivalent stress showed an increasing tendency with the varying of operating conditions from partial to excessive at both modes. In addition, the total deformation of all the operating conditions showed a small magnitude, which have quite small influence on the structural stability. It can be conjectured that this system can be safely implemented.

Intracisternal Antidepressants Suppressed the Nociceptive Jaw Opening Reflex in Freely Moving Rats

  • Ahn, Dong-Kuk;Kim, Yun-Sook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.3
    • /
    • pp.307-312
    • /
    • 1998
  • This study was performed to investigate the mechanism of central analgesic effects of antidepressants. Thirty four male rats were anesthetized with pentobarbital sodium (40 mg/kg, ip). A stainless steel guide cannula and a PE tube (PE10) were implanted into the lateral ventricle and cisterna magna area. Stimulating and recording electrodes were implanted into the incisor pulp and anterior digastric muscle. Electrodes were led subcutaneously to the miniature cranial connector sealed on the top of the skull with acrylic resin. The jaw opening reflex was used in freely moving rats, and antidepressants were administered intracisternally in order to eliminate the effects of anesthetic agents on the pain assessment and evaluate the importance of the central action site of antidepressants. After 48 hours of recovery from surgery, digastric electromyogram (dEMG) of freely moving rats was recorded. Electrical shocks (200 ${\mu}sec$ duration, 0.5-2 mA intensity) were delivered at 0.5 Hz to the dental pulp every 2 minute. Intracisternal administration of $15\;{\mu}g$ imipramine suppressed dEMG elicited by noxious electrical stimulation in the tooth pulp to $76{\pm}6%$ control. Intracisternal administration of $30\;{\mu}g$ desipramine, nortriptyline, or imipramine suppressed dEMG remarkably to $48{\pm}2,\;27{\pm}8,\;or\;25{\pm}5%$ of the control, respectively. Naloxone, methysergide, and phentolamine blocked the suppression of dEMG produced by intracisternal antidepressants from $23{\pm}2\;to\;69{\pm}4%,\;from\;32{\pm}5\;to\;80{\pm}9%,\;and\;from\;24{\pm}6\;to\;77{\pm}5%$ of the control, respectively. These results indicate that antidepressants produce antinociception through central mechanisms in the orofacial area. Antinociception of intracisternal antidepressants seems to be mediated by an augmentation of descending pain inhibitory influences on nociceptive pathways.

  • PDF

THREE DIMENSIONAL RECONSTRUCTION OF TEETH USING X-RAY MICROTOMOGRAPHY (X-ray microtomography를 이용한 치아의 3차원 재구성)

  • Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.485-490
    • /
    • 2003
  • Complete understanding of the exterior and interior structure of the tooth would be prerequisite to the successful clinical results, especially in the restorative and endodontic treatment. Although three-dimensional reconstruction method using x-ray microtomography could not be used in clinical cases, it may be the best way to reconstruct the morphologic characteristics of the tooth structure in detail without destructing the tooth itself. This study was done to three dimensionally reconstruct every teeth in the arch in order to increase the understanding about the endodontic treatment and to promote the effective restorative treatment by upgrading the knowledge of the tooth morphology. After placing tooth between the microfocus x-ray tube and the image intensifier to obtain two-dimensional images of each level. scanning was done under the condition of 80 keV, $100{\;}\mu\textrm{m}$, 16.8 magnification with the spot size of $8{\;}\mu\textrm{m}$. Cross-section pixel size of $16.28{\;}\mu\textrm{m}$ and 48.83 cross-section to cross-section distance were also used. From the results of this study, precise three dimensional reconstructed images of every teeth could be obtained. Furthermore, it was possible to see image that showed interested area only, for example. enamel portion only, pulp and dentin area without enamel structure, pulp only, combination image of enamel and pulp, etc. It was also possible to see transparent image without some part of tooth structure. This image might be used as a guide when restoring and preparing the full and partial crown by showing the positional and morphological relationship between the pulp and the outer tooth structure. Another profit may be related with the fact that it would promote the understanding of the interior structure by making observation of the auto-rotating image of AVI file from the various direction possible.

Simulation of a neutron imaging detector prototype based on SiPM array readout

  • Mengjiao Tang;Lianjun Zhang;Bin Tang;Gaokui He;Chang Huang;Jiangbin Zhao;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3133-3139
    • /
    • 2023
  • Neutron imaging technology as a means of non-destructive detection of materials is complementary to X-ray imaging. Silicon photomultiplier (SiPM), a new type of optical readout device, has overcome some shortcomings of traditional photomultiplier tube (PMT), such as high-power consumption, large volume, high price, uneven gain response, and inability to work in strong magnetic fields. Its application in the field of neutron detection will be an irresistible general trend. In this paper, a thermal neutron imaging detector based on 6LiF/ZnS scintillation screen and SiPM array readout was developed. The design of the detector geometry was optimized by geant4 Monte Carlo simulation software. The optimized detector was evaluated with a step wedge sample. The results show that the detector prototype with a 48 mm × 48 mm sensitive area can achieve about 38% detection efficiency and 0.26 mm position resolution when using a 300 ㎛ thick 6LiF/ZnS scintillation screen and a 2 mm thick Bk7 optical guide coupled with SiPM array, and has good neutron imaging capability. It provides effective data support for developing high-performance imaging detectors applied to the China Spallation Neutron Source (CSNS).

Study on the Ku band Solid-State Power Amplifier(SSPA) through the 40 W-grade High Power MMIC Development and the Combination of High Power Modules (40 W급 고출력 MMIC 개발과 고출력 증폭기 모듈 결합을 통한 Ku 밴드 반도체형 송신기(SSPA) 개발에 관한 연구)

  • Kyoungil Na;Jaewoong Park;Youngwan Lee;Hyeok Kim;Hyunchul Kang;SoSu Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • In this paper, to substitute the existing TWTA(Travailing Wave Tube Amplifier) component in small radar system, we developed the Ku band SSPA(Solid-State Power Amplifier) based on the fabrication of power MMIC (Monolithic Microwave Integrated Circuit) chips. For the development of the 500 W SSPA, the 40 W-grade power MMIC was designed by ADS(Advanced Design System) at Keysight company with UMS GH015 library, and was processed by UMS foundry service. And 70 W main power modules were achieved the 2-way T-junction combiner method by using the 40 W-grade power MMICs. Finally, the 500 W SSPA was fabricated by the wave guide type power divider between the drive power amplifier and power modules, and power combiner with same type between power modules and output port. The electrical properties of this SSPA had 504 W output power, -58.11 dBc spurious, 1.74 °/us phase variation, and -143 dBm/Hz noise level.