• 제목/요약/키워드: Guide tube

검색결과 127건 처리시간 0.019초

REPLACEMENT OF A PHOTOMULTIPLIER TUBE IN A 2-INCH THALLIUM-DOPED SODIUM IODIDE GAMMA SPECTROMETER WITH SILICON PHOTOMULTIPLIERS AND A LIGHT GUIDE

  • KIM, CHANKYU;KIM, HYOUNGTAEK;KIM, JONGYUL;LEE, CHAEHUN;YOO, HYUNJUN;KANG, DONG UK;CHO, MINSIK;KIM, MYUNG SOO;LEE, DAEHEE;KIM, YEWON;LIM, KYUNG TAEK;YANG, SHIYOUNG;CHO, GYUSEONG
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.479-487
    • /
    • 2015
  • The thallium-doped sodium iodide [NaI(Tl)] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM) has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs). It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl) gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl) $2^{\prime}{\times}2^{\prime}$ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA) to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발 (The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide)

  • 이상원;김위한;정영대;박민규;김지현;이상인;이호
    • 한국광학회지
    • /
    • 제22권1호
    • /
    • pp.46-52
    • /
    • 2011
  • 본 연구에서는 레버 증폭 구조를 이용한 플렉서 기반의 나노 스테이지를 설계, 제작하였다. 제작된 나노 스테이지를 샘플 스테이지로 채용한 공초점현미경을 개발하였다. 2차원 이미징의 구현을 위해서, 기존의 공초점현미경은 레이저를 이미징 평면상에 스캐닝하는 방식으로 구현된다. 본 연구에서는 백 나노미터의 구동정밀도를 가지는 나노 스테이지 위에 놓인 샘플을 2차원으로 스캐닝하면서 2차원 이미지를 구현할 수 있는 공초점현미경을 개발하였다. 플렉서 기반의 나노 스테이지는 이중 판스프링, 변위증폭 레버, PZT 엑추에이터 그리고 변위 센서로 구성 되어 있다. 스테이지의 구동 성능 해석을 위해 상용 유한요소 해석 프로그램을 이용하였다. 현미경에 사용되는 광원은 적색광 레이저이며, 레이저는 여러 광학요소를 거쳐 샘플스테이지의 샘플에 입사되고, 반사된 빛은 광센서인 PMT(Photo Multiplying Tube)로 계측되게 된다. 계측된 빛의 크기를 이용하여서 2차원 이미징을 구현하였다. 개발된 공초점 현미경으로 생쥐 귀의 피부조직을 관찰하여 현미경의 이미징 성능을 검증하였다. 설계된 샘플 스테이지는 기존의 공초점 현미경의 기계적인 Beam 스캐너를 대신함으로써 현미경의 광경로 및 전체시스템을 간소화 하였다.

비파괴검사 장치 내 방사선원 위치감시용 섬광필름의 발광성능 평가 (Evaluation of luminance performance of scintillating film for monitoring the position of a radioactive source in an NDT apparatus)

  • 이경진;윤정익;박병기;김신;이봉수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권1호
    • /
    • pp.13-17
    • /
    • 2005
  • 최근 비파괴검사 현장에서 검사 중 검사장치 내 방사선원의 위치를 확인하지 못하여 방사선 과피폭 사고가 종종 발생하고 있다. 본 연구는 방사선원의 노출여부나 위치 미인지로 인한 방사선 사고를 예방하기 위해 방사선원위치를 감시할 수 있는 섬광필름을 개발하는데 있다. 섬광필름은 방사선 비파괴 검사 장비의 가이드튜브 내에 존재하는 선원의 위치를 육안으로 탐지할 수 있는 신소재이다. 연구를 통해 섬광필름의 발광성능을 평가하고 최적의 필름 설계를 꾀하였다. 필름에 적용된 발광물질은 무기 섬광체를 이용하였고, 다양한 층을 갖는 형태의 필름을 제작하여 성능을 평가하였다. 필름의 발광성능은 광도계를 이용하여 측정하였고, 비파괴 검사장비는 Ir-192 감마선 조사기를 사용하였다. 실험결과, 섬광필름의 발광은 육안으로 선원의 위치를 감시할 수 있었으며, 선원의 이동에 따라서 발광영역도 동시에 이동하면서 형성되었다. 또한, 섬광필름에 반사층을 두는 것은 광 이용률의 증대시켜 발광성능을 높이는 데 매우 효과적이었다. 섬광체와 분산용제의 혼합비에 따라서도 성능변화가 나타났으며, 일반적으로 섬광체의 양이 높을수록 발광성능은 높게 나타났다. 그러나 분산 특성이 변화로 혼합비는 일정 농도 이하로 제한되었다. 섬광체 중에서는 $Gd_2O_2S(Tb)$ 무기섬광체가 가장 높은 발광성능을 보여주었다. 개발된 섬광필름을 비파괴 검사 장비에 적용하게 된다면 방사선종사자에게 보다 안전한 작업환경을 제공할 수 있을 것이다.

  • PDF

APPLICATION OF A GENETIC ALGORITHM FOR THE OPTIMIZATION OF ENRICHMENT ZONING AND GADOLINIA FUEL (UO2/Gd2O3) ROD DESIGNS IN OPR1000s

  • Kwon, Tae-Je;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.273-282
    • /
    • 2012
  • A new effective methodology for optimizing the enrichment of low-enriched zones as well as gadolinia fuel ($UO_2/Gd_2O_3$) rod designs in PLUS7 fuel assemblies was developed to minimize the maximum peak power in the core and to maximize the cycle lifetime. An automated link code was developed to integrate the genetic algorithm (GA) and the core design code package of ALPHA/PHOENIX-P/ANC and to generate and evaluate the candidates to be optimized efficiently through the integrated code package. This study introduces an optimization technique for the optimization of gadolinia fuel rod designs in order to effectively reduce the peak powers for a few hot assemblies simultaneously during the cycle. Coupled with the gadolinia optimization, the optimum enrichments were determined using the same automated code package. Applying this technique to the reference core of Ulchin Unit 4 Cycle 11, the gadolinia fuel rods in each hot assembly were optimized to different numbers and positions from their original designs, and the maximum peak power was decreased by 2.5%, while the independent optimization technique showed a decrease of 1.6% for the same fuel assembly. The lower enrichments at the fuel rods adjacent to the corner gap (CG), guide tube (GT), and instrumentation tube (IT) were optimized from the current 4.1, 4.1, 4.1 w/o to 4.65, 4.2, 4.2 w/o. The increase in the cycle lifetime achieved through this methodology was 5 effective full-power days (EFPD) on an ideal equilibrium cycle basis while keeping the peak power as low as 2.3% compared with the original design.

가정간호과정생의 가정간호에서의 감염관리에 대한 지식 (Knowledge on Infection Control for Home Care)

  • 정인숙;정재심;신용애;강규숙;김명자;조복희;김금순;황선경
    • 가정간호학회지
    • /
    • 제9권1호
    • /
    • pp.5-13
    • /
    • 2002
  • This study was conducted to assess need for education on the infection control by examining the knowledge on infection control in home care of the home care trainees who had completed an infection control course. Using 64 items questionnaire. home care trainees of eight home care education institutions who took classes related with infection control. The level of knowledge evaluated subjectively was 4.24point (full mark: 5 point). The correct answer rates for handwashing and gloving. cleaning patients' rooms. preventing sharp injury, preventing exposure to potential infectious agents, home care bag technique were 84.5% 86.4% 70.7% 65.3% 76.2% representatively. For the knowledge on the infection control principles to prevent catheter related infection, indwelling catheter related infection, tracheal tube related pneumonia. L-tube related infection, oxygen therapy related infection. and wound infection were 62.8% 27.8% 39.1% 87.8% 76.5% 80.5% representatively. The correct answer rates varied depending upon the educational institutes (p< = .0001), educational levels (p= .001), workplaces (p<.0001), and the experience of infection control education (p= .001). Considering these results. a standardized curriculum must be developed and implemented after analyzing the existing infection control curricula of the home care education institutes. and guide books for infection control in home care should be developed and distributed. In addition. continuous infection control education be provided to the home care nurses through reeducation so they can acquire new knowledge needed for carrying out infection control activities effectively.

  • PDF

나노미터 영역 길이 측정 위한 미터 소급성을 갖는 원자간력 현미경 개발 (Development of a Metrological Atomic Force Microscope for the Length Measurements of Nanometer Range)

  • 김종안;김재완;박병천;엄태봉;홍재완
    • 한국정밀공학회지
    • /
    • 제21권11호
    • /
    • pp.75-82
    • /
    • 2004
  • A metrological atomic force microscope (M-AFM) was developed fur the length measurements of nanometer range, through the modification of a commercial AFM. To eliminate nonlinearity and crosstalk of the PZT tube scanner of the commercial AFM, a two-axis flexure hinge scanner employing built-in capacitive sensors is used for X-Y motion instead of PZT tube scanner. Then two-dimensional displacement of the scanner is measured using two-axis heterodyne laser interferometer to ensure the meter-traceability. Through the measurements of several specimens, we could verify the elimination of nonlinearity and crosstalk. The uncertainty of length measurements was estimated according to the Guide to the Expression of Uncertainty in Measurement. Among several sources of uncertainty, the primary one is the drift of laser interferometer output, which occurs mainly from the variation of refractive index of air and the thermal stability. The Abbe error, which is proportional to the measured length, is another primary uncertainty source coming from the parasitic motion of the scanner. The expanded uncertainty (k =2) of length measurements using the M-AFM is √(4.26)$^2$+(2.84${\times}$10$^{-4}$ ${\times}$L)$^2$(nm), where f is the measured length in nm. We also measured the pitch of one-dimensional grating and compared the results with those obtained by optical diffractometry. The relative difference between these results is less than 0.01 %.

전자기유량계의 설계 및 제작 (Design and Fabrication of an Electromagnetic Flowmeter)

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제27권10호
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

Characteristics of Synchronous and Asynchronous modes of fluctuations in Francis turbine draft tube during load variation

  • Goyal, Rahul;Cervantes, Michel J.;Gandhi, Bhupendra K.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권2호
    • /
    • pp.164-175
    • /
    • 2017
  • Francis turbines are often operated over a wide load range due to high flexibility in electricity demand and penetration of other renewable energies. This has raised significant concerns about the existing designing criteria. Hydraulic turbines are not designed to withstand large dynamic pressure loadings on the stationary and rotating parts during such conditions. Previous investigations on transient operating conditions of turbine were mainly focused on the pressure fluctuations due to the rotor-stator interaction. This study characterizes the synchronous and asynchronous pressure and velocity fluctuations due to rotor-stator interaction and rotating vortex rope during load variation, i.e. best efficiency point to part load and vice versa. The measurements were performed on the Francis-99 test case. The repeatability of the measurements was estimated by providing similar movement to guide vanes twenty times for both load rejection and load acceptance operations. Synchronized two dimensional particle image velocimetry and pressure measurements were performed to investigate the dominant frequencies of fluctuations, vortex rope formation, and modes (rotating and plunging) of the rotating vortex rope. The time of appearance and disappearance of rotating and plunging modes of vortex rope was investigated simultaneously in the pressure and velocity data. The asynchronous mode was observed to dominate over the synchronous mode in both velocity and pressure measurements.

알루미늄 합금의 일정 곡률 압출공정 개발 (Process Development of Constant Curvature Extrusion for Aluminum Alloy)

  • 조영준;이상곤;오개희;박상우;김병민
    • 소성∙가공
    • /
    • 제16권7호
    • /
    • pp.555-560
    • /
    • 2007
  • This paper shows some achievements at bending of extruded aluminum profiles during the extrusion process. The conventional process for the production of bent profiles involves a successive extrusion, stretching, and bending of the profiles. Conventional bending methods can not meet demands far precision and cost-effective production in some cases, due to cross sectional deformation, irregular decrease of tube wall thickness and a complication of the process design. An estimation of spring-back required for precision of the bending radius can not always be achieved by the over bending of the profile. Since the profile is hot during the bending process, the spring-back phenomenon can be avoided. This means that an additional bending process is not necessary. Consequently, flexible bending can be achieved with cost reduction and quality improvement. Experimental tests were completed to study the relationship between curvature radius of profile and position of guide on the extrusion for vehicle bumper. A7108 is applied as a billet material in order to increase strength. The overall correlation between the experimental and numerical results is good. It is therefore concluded that the present method provides an efficient means for the constant curvature extrusion process.

Robert H. Koch's Work on Lightweight Medium-Aperture Mirrors

  • Holenstein, Bruce D.;Mitchell, Richard J.
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권1호
    • /
    • pp.79-84
    • /
    • 2012
  • After a visit by Peter Waddell from the University of Strathclyde, Glasgow, UK in 1991, Robert H. Koch launched a program at the University of Pennsylvania to build lightweight pneumatic membrane mirrors, initially for balloon flight observations where weight is at a premium. Mirror cells were fabricated from sizes 0.18 m to 1.77 m, and experiments conducted to characterize the mirror figure and stability. Most of the work stopped after Prof. Koch's retirement in 1996 until 2006 when the authors expressed an interest in building an array of medium-aperture portable telescopes. The program restarted in earnest at Gravic, Inc. in Malvern, PA in 2008 with Koch using his extensive observational astronomy experience to guide the fabrication of a fully operational 1.07 m membrane mirror telescope with an optical tube assembly weighing under 45 Kg. Residual wavefront aberrations remediation resulted in Koch and the authors investigating membrane tensioning techniques with different cell designs, active secondary wavefront correction, photometric algorithms for aberrated images, and the use of additional lightweight mirror substrates from the Alt-Az Initiative Group, such as foamed glass. The best result for the lightweight mirrors was a point spread function spot size of several arc seconds. A lightweight 1.6 m cast aluminum cell alt-az telescope was subsequently designed by Koch and the authors for prime focus use.