• Title/Summary/Keyword: Guide 1.60

Search Result 174, Processing Time 0.097 seconds

A Study on Cutting Mechanism and Wear Character for BTA Drill (BTA드릴의 절삭 기구와 마모 특성에 관한 연구)

  • 장성규;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.105-108
    • /
    • 1995
  • So far,in deep drilling process there are several manufacturing problems such as hole deviation, hole over size, circularity,straightness and surface roughness. Whit regard to these problems, we atudied the abrasion process on carbided tip of BTA drill and got the follow test results through the abrasion characteristic test and analysis on cutting mechanism for the drill tooth and guide pad. 1) In SM55C drilling process, the most stable and reasonable drilling speed range for optmum abrasion characteristic of drill tooth was 60m.min. 2) The total drilling torque was about 60kg .deg.cm on condition drilling speed 60m/min and 0.15mm/rev. These results show that the theoretical burnising torque is well accord with the tested torque which is working on guide pad.

  • PDF

A Study on an Integrated Light Guide Plate (광학시트를 제거한 복합 도광판 설계 연구)

  • Lee, Yun-Mi;Lee, Jun-Ho;Jeon, Eun-Chae
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.2
    • /
    • pp.53-60
    • /
    • 2010
  • An integrated light guide plate (LGP) was designed for liquid crystal displays (LCD) without using prism and diffuser sheets. The integrated LGP is textured with micro-patterns on both the top and bottom surfaces. The textures effectively substitute for a single prism-sheet and a diffuser sheet in LCD displays without decreasing the brightness and uniformity. A LCD display with our integrated light guide is simulated to give average luminance of 4560 cd/$m^2$, luminance uniformity of 83% horizontal viewing angle $60^{\circ}$ and vertical viewing angle $56^{\circ}$. Therefore an ultra thin (slim) back light unit can be constructed with fewer optical sheets, which reduces the manufacturing cost and so improves price competitiveness.

Improvement on the Method of Estimating Radionuclide Concentrations in Agricultural Products for the Off-Site Internal Dose Calculation for Operating Nuclear Facilities (가동중 원자력 시설 주변 주민의 내부피폭선량 계산을 위한 농산물내 핵종 농도 평가법 개선)

  • Choi, Y.H.;Lim, K.M.;Hwang, W.T.;Choi, G.S.;Choi, H.J.;Lee, C.W.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.73-90
    • /
    • 2004
  • The Reg. Guide 1.109 model was reviewed against its applicability to calculating radionuclide concentrations in agricultural products for operating nuclear facilities and an improved method was proposed. The model was so modified that the radionuclides deposited since the start of operation could be considered in assessing the root uptake. Translocation factors were introduced in the equation for calculating the concentrations in edible parts due to direct plant deposition. Values specific to Korea were set up for the input parameters of the modified model. The concentrations of $^{54}Mn,\;^{60}Co,\;^{90}Sr\;and\;^{137}Cs$ in rice seeds, Chinese cabbage and radish root were calculated for various hypothetical deposition histories using the Reg. Guide 1.109 model and the modified model with parameter values in the guide and those specific to Korea put in alternately. Through comparisons among the results, it could be expected that the use of the modified model with the input of parameter values specific to Korea would result In a more resonable and realistic assessment.

Effect of the Shape of a Guide Grill Above a Resonance Type Sound Absorbing Panel on Intake Flow into a Resonator (공명 흡음판 위 가이드 그릴의 형상이 공진기 흡입 유동에 미치는 영향)

  • Bae, Hyunwoo;Sung, Jaeyoung;Lee, Dong Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study investigates cavity flows through a guide grill above a resonator. Vortex distributions and intake flows are simulated for various shapes of the guide grill. The flows are assumed to be compressible, unsteady, and turbulent. Numerical simulations are conducted using a large eddy simulation (LES) model. To analyze the effect of the guide grill shape, three cavity lengths (0.2H, 0.6H, and 1.0H) and cavity angles ($30^{\circ}$, $45^{\circ}$ and $60^{\circ}$) are considered based on resonator height (H). The results show that the vortex generated in the resonator by cavity flow increases with cavity length. Thus, the intake flow is minimum at the smallest cavity length and angle. However, when cavity length is equal to resonator height, the intake flow decreases. The maximum intake flow occurs at a cavity angle $45^{\circ}$ at higher cavity lengths owing to the interaction between the vortex in the resonator and intake flow.

Design of Nonreciprocal Twin-toroidal Ferrite Phase Shifter (비가역성 쌍토로이드 페라이트 변위기 설계)

  • 이기오;김영범;박동철;신용수;김윤명
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.1
    • /
    • pp.43-52
    • /
    • 1996
  • Nonreciprocal twin-toroid ferrite phase shifter is designed, fabricated, and tested. ABCD matrix method is used to design the phase shifter and to compute its optimum dimen- sions. Quarter-wave two-section impedance matching transformers are utilized in order to match the impedance of the empty guide to that of the ferrite-loaded guide. Driving circuit controls the current needed to drive the phase shifter. Measured insertion loss and VSWR characteristics within the operaring band(9.1GHz ~ 9.5GHz) are less than 1.2dB and 1.15, respectively. After temperature compensation technique is appied to the phase shifter, the measured phase error of the phase shifter is less than $\pm4$ between $-10^{\circ}C\;and\;+60^{\circ}C$.

  • PDF

An Experimental Study on the Thermal Performance of Air filled Thermal Diode during Transfer Process (공기를 작동 유체로 하는 열다이오드의 천이 과정중 열성능에 관한 실험적 연구)

  • 황인주;장영근;박이동;김철주
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.171-175
    • /
    • 1996
  • thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient process of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. Gr was kept constantly on 1.60$\times$1010 and error range was $\pm$2% during the experiment. Nu was examined when inclined angle are 15$^{\circ}$and 45$^{\circ}$and, also the experiments was carried out with and without guide vane as well. Specially, The effect of guide vane was sensitive. Developed region inclined angle, which is characteristic of system.

  • PDF

Adjustable Ghajar Guide Technique for Accurate Placement of Ventricular Catheters : A Pilot Study

  • Yoon, Sang-Youl;Kwak, Youngseok;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.604-609
    • /
    • 2017
  • Objective : An adjustable Ghajar guide is presented to improve the accuracy of the original Ghajar guide technique. The accuracy of the adjustable Ghajar guide technique is also investigated. Methods : The coronal adjustment angle from the orthogonal catheter trajectory at Kocher's point is determined based on coronal head images using an electronic picture archiving and communication system. For the adjustable Ghajar guide, a protractor is mounted on a C-shaped basal plate that is placed in contact with the margin of a burrhole, keeping the central $0^{\circ}$ line of the protractor orthogonal to the calvarial surface. A catheter guide, which is moved along the protractor and fixed at the pre-determined adjustment angle, is then used to guide the ventricular catheter into the frontal horn adjacent to the foramen of Monro. The adjustable Ghajar guide technique was applied to 20 patients, while a freehand technique based on the surface anatomy of the head was applied to another 47 patients. The accuracy of the ventricular catheter placement was then evaluated using postoperative computed tomography scans. Results : For the adjustable Ghajar guide technique (AGT) patients, the bicaudate index ranged from 0.23 to 0.33 ($mean{\pm}standard$ deviation [SD] : $0.27{\pm}0.03$) and the adjustment angle ranged from $0^{\circ}$ to $10^{\circ}$ ($mean{\pm}SD:5.2^{\circ}{\pm}3.2^{\circ}$). All the AGT patients experienced successful cerebrospinal fluid diversion with only one pass of the catheter. Optimal placement of the ventricular catheter in the ipsilateral frontal horn approximating the foramen of Monro (grade 1) was achieved in 19 patients (95.0%), while a suboptimal trajectory into a lateral corner of the frontal horn passing along a lateral wall of the frontal horn (grade 3) occurred in 1 patient (5.0%). Thus, the AGT patients experienced a significantly higher incidence of optimal catheter placement than the freehand catheterized patients (95.0% vs. 68.3%, p=0.024). Moreover, none of the AGT patients experienced any tract hemorrhages along the catheter or procedure-related complications. Conclusion : The proposed adjustable Ghajar guide technique, using angular adjustment in the coronal plane from the orthogonal trajectory at Kocher's point, facilitates accurate freehand placement of a ventricular catheter for hydrocephalic patients.

Environmental Fatigue Evaluation of APR1000 Reactor Vessel (APR1000 원자로용기의 환경피로 평가)

  • Kim, Jong Min;Kim, Yong Hwan
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.3
    • /
    • pp.207-212
    • /
    • 2013
  • APR1000(Advanced Power Reactor 1000) was developed to export 1000MW nuclear power plants by adding ADFs(Advanced Design Features) including 60 years design life, local frequency control operation, 0.3g SSE, etc. to OPR1000(Optimized Power Reactor 1000). In this paper, environmental fatigue analyses for the reactor vessel in APR1000 have been performed as per Reg. Guide 1.207. Outlet nozzle, which has a relatively high cumulative usage factor in the reactor vessel was evaluated and a structural integrity is maintained under the reactor coolant environment.

Design and Operating Characteristics of Cylindrical Linear Motor for Long Stroke Precision Stage (롱 스트로크 정밀 스테이지용 원통형 리니어모터의 설계 및 운전 특성)

  • An, Geuk-Sub;Kim, Houng-Joong;Ahn, Jin-Woo;Koseki, Takafumi
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.63-70
    • /
    • 2011
  • This paper presents the design and operating characteristics of the novel cylindrical linear motor which is designed for the long stroke XY stage. In the long stroke structure, the air gap is changed by the distortion and bending effects, and it makes additional position error in the XY stage. In order to consider the distortion and bending effects of the long stroke, the field part of the cylindrical linear motor is designed as an open structure, and the stroke is supported by the bridge guide which is positioned in the open field part. The mechanical bridge guide can reduce the bending effects of the stroke and can keep a constant air gap. The detailed design process of the proposed cylindrical linear motor is presented in this paper. The proposed motor is analyzed by the 3D FEM technology. The practical XY stage which uses the proposed motor is tested to verify the propose novel cylindrical linear motor. The FEM and experimental results show the effectiveness of the proposed motor.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.