• Title/Summary/Keyword: Group separation

Search Result 611, Processing Time 0.032 seconds

Blend Characteristics of PBT, Nylon6,12 and Preparation of PBT/Nylon6,12 Micro Fiber with Core/shell Structure and their Extrusion Conditions (PBT와 Nylon6,12의 블렌드 특성과 core/shell 구조를 갖는 PBT/Nylon6,12 미세모의 제조 및 압출조건)

  • Park, Hui-Man;Lee, Seon-Ho;Kwak, Noh-Seok;Hwang, Chi Won;Park, Sung-Gyu;Hwang, Taek Sung
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1068-1075
    • /
    • 2012
  • Poly(butylene terephthalate) (PBT)/Nylon6,12 core/shell micro fiber were prepared by extrusion molding. To investigate their optimum extrusion conditions, compatibility of PBT/Nylon6,12 blend micro fiber in conformity to their weight ratio and manufacture temperature was explored with SEM morphology and DSC. The alterations in their mechanical properties by extrusion speed were compared and analyzed through a UTM. In comparison with SEM figures, the domain sizes of Nylon6,12 were gradually declined by increasing the extrusion temperature of blends. Furthermore, according to these SEM images, the phase separation between Nylon6,12 domain and PBT matrix became indistinct with increasing of weight percentage of Nylon6,12. In case of DSC, the boundaries of two peaks were almost disappeared when increasing the extrusion temperature and also intervals of each two melting peaks became narrow as increasing the Nylon6,12 ratio. The mechanical properties including tensile strength, elongation, flexural strength and flexural modulus were increased as the increase in the extrusion temperature until $260^{\circ}C$. However, the mechanical properties were actually deteriorated over $260^{\circ}C$. The tensile strength, elongation, flexural strength and flexural modulus at $260^{\circ}C$ were 560 $kg_f/cm^2$, 220%, 807 $kg_f/cm^2$ and 22,146 $kg_f/cm^2$, respectively. These values are more than intermediate values of mechanical properties of PBT and Nylon6,12. These results mean that there is compatibility between PBT and Nylon6,12. Based on the extrusion conditions that produced optimum compatibility of blend, as a result, our group obtained micro fibers with the core/shell structure.

Globalization and Independency of Populist Nations' Welfare Policies: Focusing on the Influences of Multinational Pharmaceutical Companies on the Korean Government's Policy on the Pharmaceutical Industry (세계화와 국민국가의 복지정책 자율성: 다국적 제약자본이 우리나라 제약정책 결정에 미친 영향을 중심으로)

  • Lee, Su-Yun;Kim, Young-Mi
    • Korean Journal of Social Welfare
    • /
    • v.57 no.3
    • /
    • pp.5-30
    • /
    • 2005
  • Globalization has conflicting effects on pharmaceutical policies. A change into a 'populist competitive nation' due to globalization strengthens policies to reduce drug manufacturing costs while the WTO's TRIPS Agreement that is affected by multinational pharmaceutical companies increases drug manufacturing costs by bolstering the patent rights on new drugs. Currently, the independency of populist nations' policies to reduce drug manufacturing cost is being compromised because multinational organizations(such as the European Union) which represents the interests of the multinational pharmaceutical companies put restrictions on the pharmaceutical policies of populist nations for purposes of promoting the industrial goals of the multinational companies. Korea is no exception. Up until the late 1990s, the main feature of the pharmaceutical policies in Korea was keeping the drug price at the cost level based on a growth-driven ideology, and this was Korea's unique policy tools as a developing nation. However, the increase in the power of multinational pharmaceutical companies currently infringes on the independency of Korea's pharmaceutical policies. Expensive imported drugs were originally covered by the national health insurance plan, but starting from 1999 such drugs began to be covered by the plan. After separation of medical and pharmaceutical services, the use of expensive drugs was increased, and the Korean government planned to introduce the reference price policy in order to contain the cost of the national health insurance plan. However, due to pressures from the U.S. government as well as multinational pharmaceutical companies, implementation of the policy has been postponed. In addition, due to a pressure from the U.S. government, a working group was created which would affect the health care policy of the Korean government. Discussions so far on globalization was about whether the change into populist competitive nations due to globalization resulted in the reduction of welfare spending. However, this study shows not only the reduction of health care cost through policies to reduce drug manufacturing costs but increase in welfare spending by raising the strengths of multinational pharmaceutical companies that are for-profit providers of welfare service. While focusing on the contradictory effects of globalization on pharmaceutical policies of a nation, this study looked at how these conflicting effects end up promoting the interests of multinational pharmaceutical companies by examining the Korean case.

  • PDF

Effect of Processing Conditions on the Physical and Sensory Characteristics of Pork Cutlets (가공조건이 Pork Cutlet의 물리적 및 관능적 특성에 미치는 영향)

  • Kim Il-Suk;Min Joong-Seok;Lee Sang-Ok;Jang Aera;Kim Dong-Hoon;Jin Sang-Kuen;Lee Mooha
    • Food Science of Animal Resources
    • /
    • v.24 no.4
    • /
    • pp.319-325
    • /
    • 2004
  • The objective of the present study was to investigate the effect of processing conditions on the physical and sensory properties of pork cutlet produced from chilled pork loin (T1), the cured and massaged chilled pork loin (T2), the cured and massaged frozen pork loin (T3), frozen pork loin (T4), massaged frozen pork loin (T5). Water holding capacity (WHC) of pork cutlets were not significantly different among the treatments. In chilled pork loin, WHC of T2 were slightly higher than that of T1. T4 showed the lowest WHC among all treatment group. In meat color, CIE L$\^$*/, a$\^$*/. b$\^$*/ values in chilled pork loin were not significantly different between T1 and T2. L$\^$*/ values of T3 and T5 were higher than that of T4. a$\^$*/ values were not significantly different among the all treatments. T3 produced through the curing and massaging treatment showed the highest tenderness in shear force (p< 0.001), while force value (kg/㎤) of T4 were the highest among all treatments. Separation ratio of wheat dough from pork cutlet was highest (p.<0.001) in T4. In triangle test, T1 : T3 combination was higher than that of other pairs. No differences in acceptability of sensory evaluation were observed among T1, T2, T3, and T5 groups, while the frozen pork showed the lowest (p<0.001) acceptability. In conclusion, pork cutlets from T4 with the curing and/or massaging process showed similar acceptance than those from chilled pork loins, and this treatments may contribute to promote the consumption of frozen pork loins.

A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower (역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구)

  • Kang, Sung Jin;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.

The Study on Formation of Deoneum of 19th Century's Sugungga (19세기 수궁가의 더늠 형성에 관한 연구)

  • Lee, Jin O
    • (The) Research of the performance art and culture
    • /
    • no.36
    • /
    • pp.185-221
    • /
    • 2018
  • This study examined the process of the formation of Deoneum, Sugungga(水宮歌), and its tendency of the change through the trace of the Pansori masters who worked in 19th century. The time that the main group of the Sugungga masters appeared in the Pansory history is estimated in early 19th century. The Sugungga masters in this time could be divided in two groups, one is the early days masters who worked in early 19th century and the other is the latter days masters who worked in middle and late 19th century. Kwon Sam-deuk(權三得), Song Heung-lok(宋興祿), Yeom Gyeo-dal(廉季達), and Shin Man-yeob(申萬葉) are the Sugungga masters who worked in early 19th century. By the records they left, I could confirm that they used the description about the dramatic characteristics in the work and Soritjo(Pansori master's tonality), like the appearance of 'Bangge(crab)' and 'Tiger', and particularly they developed which has the scene of the Rabbit's deceiving the Dragon King and Rabbit's return, 'Goandaejangja(寬大長者)', 'Gaja-Eoseoga', 'Sojinowha(笑指蘆花)', 'Apnae-Beodeuleun' and the scene of 'Rabbit's curse(the part that Rabbit curses Byeljubu)' etc. I could understand that the interest of the early days Pansori masters about Sugungga is on the characters and the latter part of the work. The separation of Dongpyeonje(東便制) and Seopyeonje(西便制) of Pansori was done in the middle and late 19th century. As the Dongpyeonje master, Song Wu-ryong(宋雨龍), Park Man-sun(朴萬順), Song Man-gab(宋萬甲), Shin Hak-jun(申鶴俊) and Yu Seong-jun(劉成俊) worked. As the Seopyeonje masters, Park Yu-jeon(朴裕全), Kim geo-bok(金巨福), Kim Su-yeong(金壽永) and Baek Gyeong-jun(白慶順) etc. sang Sugungga. The Dongpyeonje masters developed the 'Toggigibyeon(토끼奇變)' related Deoneum paying attention on the latter part of Sugungga same as the early days masters. Meanwhile it looks like that they had interest in developing the parts which belong to the middle and early parts of Sugungga like 'Toggiwhasang(토끼畵像)', 'Gogocheonbyeon(皐皐天邊)' and 'Tobyeolmundab(兎鱉問答)'. The Seopyeonje masters developed the parts belong to the early part of Sugungga, which are related to Dragon King and the courtiers in Sugung palace, like 'YongwangTansik(龍王歎息)'. And I could confirm that they developed the parts influenced by Shin Jaehyo's editorials like 'Tosahobi(兎死狐悲)' and 'Goguksancheon(故國山川)' etc. In short, I could confirm the trend that the Pansori masters in 19th century had interest in from the latter part to the early part of Sugungga. If taking a look focusing on main characters, they moved their interest in from Rabbit to the courtiers including Byeoljubu(鱉主簿) and Dragon King in Sugung palace, and it could say that, in this trend, Sori part and Deoneum were developed.

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.

Microbiological Hazard Analysis of Sundae (Korean Sausage) Made of Meat By-Products (식육 부산물을 활용한 순대의 미생물학적 위해 분석)

  • Cheong, Jin-Sook;Kim, Yun Jeong;Om, Ae-Son
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.181-188
    • /
    • 2022
  • Despite the recent increase in the consumption level of the processed meat-byproducts, the health and safety issue has consistently been raised in the processes of production, distribution and consumption. The purpose of this study is to analyze and evaluate the microbiological hazard elements in the Korean sausage, "Sundae," to present not only the safety standard of meat by-product vendors based on HACCP (Hazard Analysis Critical Control Point), but also the quality control criteria and sanitary arrangements of small manufacturers. For the study, the microbiological hazards in 24 raw materials, 7 manufacturing processes, 40 facilities and tools, 17 workplace environment, and 12 workers were analyzed. The analysis revealed the hazardous elements in the initial stages with 6.28 and 4.07 log CFU/g of total aerobic count and coliforms, respectively, detected from the porcine blood and 3.23 log CFU/g of coliforms from the porcine small intestines. The result also showed that the total aerobic counts and coliforms in the process of mixing and filling process exceeds the standards in the hygiene guidelines by Natick with the total aerobic counts of 5.23, 5.45 log CFU/g, and the coliforms of 3.25, and 3.31 log CFU/g, respectively. Although the detected total aerobic count and the coliforms in the filling and washing rooms exceeded the standards, it was found that the total aerobic count was significantly reduced by 98% after cleaning and disinfecting and no coliforms was detected in any process thereafter. In order to achieve high level of safety in the manufacturing processes of Sundae, the separation of washing and disinfection room from the other sections and the sanitation control of the workers must be preceded, along with strict monitoring in the storage and distribution processes. The study raises necessity for additional studies for the safety evaluation of the processed meat-byproducts and further researches on the validity of the critical limits.

Fecal Microbiota Profiling of Holstein and Jersey, in South Korea : A Comparative Study (국내에서 사육되는 Holstein 젖소과 Jersey 젖소의 대변 미생물 분석 : 비교연구)

  • Gwangsu Ha;Ji-Won Seo;Hee Gun Yang;Se Won Park;Soo-Young Lee;Young Kyoung Park;RanHee Lee;Do-Youn Jeong;Hee-Jong Yang
    • Journal of Life Science
    • /
    • v.33 no.7
    • /
    • pp.565-573
    • /
    • 2023
  • In light of the complex interactions between the host animal and its resident gut microbiomes, studies of these microbial communities as a means to improve cattle production are important. This study was conducted to analyze the intestinal microorganisms of Holstein (HT) and Jersey (JS), raised in Korea and to clarify the differences in microbial structures according to cattle species through next-generation sequencing. The alpha-diversity analysis revealed that most species richness and diversity indices were significantly higher in JS than in HT whereas phylogenetic diversity, which is the sum of taxonomic distances, is not significant. Microbial composition analysis showed that the intestinal microbial community structure of the two groups differed. In the both groups, a significant correlation was observed among the distribution of several microbes at the family level. In particular, a highly significant correlation (p<0.0001) among a variety of microbial distributions was found in JS. Beta-diversity analyis was to performed to statistically verify whether a difference exists in the intestinal microbial community structure of the two groups. Principal coordinate analysis and unweighted pair group method with arithmetic mean (UPGMA) clustering analysis showed separation between the HT and JS clusters. Meanwhile, permutational multivariate analysis of variance (PERMANOVA) revealed that their microbial structures are significantly different (p<0.0001). LEfSe biomarker analysis was performed to discover the differenc microbial features between the two groups. We found that several microbes, such as Firmicutes, Bacilli, Moraxellaceae and Pseudomonadales account for most of the difference in intestinal microbial community structure between the two groups.

Changing Aspects and Factors of Shaman's Play in Donghaeanbyeolsingut (동해안별신굿 굿놀이의 변화양상과 요인)

  • Kim, Shin-Hyo
    • (The) Research of the performance art and culture
    • /
    • no.38
    • /
    • pp.33-69
    • /
    • 2019
  • In this article, I would like to pay attention to the changesofShaman's play as a part of examining the process of changeofDonghaeanbyeolsingut. Currently, Shaman's play can be seeninBaekseok2-ri, Byeonggok-myeon, Yeongdeok-gun, Gugye-ri, Namjeong-myeon and Yeongdeok-gun. Among them, ShamanRitual of Baekseok2-ri is short in cycle and easy to see change. InShaman Ritual of Baekseok2-ri, various Shaman's plays suchasJungdodukjabi(중도둑잡이), Wonnimnori(원님놀이), Talgut(탈굿), Mallori(말놀이), Hotalgut(호탈굿) and Georigut(거리굿) areperformed. Shaman's play carried out in Donghaeanbyeolsingut changesevery time it is carried out. Depending on the degree of change, itcan be classified into passive change and positive change. Whilepassive changes are improvisational, aggressive changes areintentional. Shaman's plays are jungdodukjabi, Mallori, Hotalgut, which are the improvisational changes, and the intentional changesare Wonnimnori, Talgut, Georigut. The biggest change in Shaman's play is the disappearance of the Shaman Ritual. The Shaman Ritual is suspended due to lackofpeople, financial difficulties, religious conflicts or rational accidents. Secondly, the period of separation is shortened or shortened. Thiscauses Shaman's play to be dropped or shrunk to change. InShaman Ritual, changes in Shaman's play are variable andcreative. The change due to the intervention of the spectatorsismainly improvisation. On the other hand, the change bythepreliminary plan of the acquaintance is intentional, and the changeis large. The changing factors of Shaman's play are influenced bythedemands of the times and the recognition of the tradition group. Changes in the traditional environment can be attributed to lackofhuman resources, individualism, changes in the workingenvironment and time constraints. At the same time, givingautonomy to traffickers is a major reason for Shaman's playtochange.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF