• Title/Summary/Keyword: Groundwater Drawdown

Search Result 116, Processing Time 0.023 seconds

Characterization of Groundwater Flow to Horizontal or Slanted Well Using Numerical Modeling (수치 모사를 활용한 수평 혹은 경사형 특수 정호 지하수 흐름 특성 평가)

  • Kim, Hyoung-Soo
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.2
    • /
    • pp.54-61
    • /
    • 2008
  • The drawdown distribution due to pumping by horizontal or slanted wells is analyzed by numerical modelling. In the numerical modelling uses 1-D discrete element feature included in commercial groundwater modeling program FEFLOW (version 5.1) and the results are compared with the semi analytic solution which uses superposition of successive point sources proposed by Zhan and Zlotnik (2002). Results of the numerical modeling agree well with the semi analytic solution except for very near field region of sink sources. The drawdown distribution due to pumping in riverbank filtration(RBF) plan site can be evaluated quantitatively by the numerical modeling in this study.

A Study on the Variation of Groundwater Level in the Han River Estuary (The Effect of the Removing of a Weir) (한강 하구역에서의 지하수위 변화에 관한 연구(수중보 철거로 인한 영향))

  • Kim, Sang-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.6
    • /
    • pp.589-601
    • /
    • 2008
  • The variation of groundwater level near the Shingok weir has been analyzed. To consider the soil inhomogeneity, coefficient of effective permeability was computed to be 0.313 m/day in the horizontal direction, and 0.0423 m/day in vertical direction. Anisotropic ratio is 7.19. The river water level drawdown (caused by the removing of the weir) causes the groundwater level drawdown, and 3 months are required for the new steady condition. and groundwater flows from Han river toward Gulpo stream before the removing of the weir, but when the weir removed, the flow direction changes. The groundwater level falls maximum 30 cm in the areas under the influence of Han river, but, in the areas near Kulpo stream, groundwater level falls about 10 cm. The amount of groundwater use in the study area was investigated to be $52m^3/day$ and in this condition, groundwater level falls maximum 1m (before or after the removing of Shingok weir). therefore, the variation of groundwater level caused by the removing of Shingok weir is less than that caused by the usual use of groundwater.

The Pore Volume of Groundwater Level Drawdown Zone Through Slug/Bail Tests in Sand and Silt Soils (모래와 실트의 혼합층에서 순간충격시험에 의한 지하수위 강하구역의 공극체적 산정)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Chung, Sang-Yong;Yang, Sung-Il;Lee, Min-Hee
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Slug/bail tests were conducted in sand layer (sbt-1 well), silty sand layer (sbt-2 well), and mixed sand and silty sand layer (sbt-3 well). Hydraulic conductivity and specific storage coefficient were estimated through slug/bail tests. Pore volumes of groundwater level drawdown zone for bail test were estimated by using hydraulic conductivity and specific storage coefficient. KGS model was most suitable interpretation method of slug/bail tests. Average hydraulic conductivity for slug/bail tests were estimated to be $6.65{\times}10^{-5}$ m/sec in sbt-1 well, $6.33{\times}10^{-6}$ m/sec in sbt-2 well, and $3.72{\times}10^{-5}$ m/sec in sbt-3 well. Average specific storage coefficient for slug/bail tests were estimated to be 0.0225 in sbt-1 well, 0.0177 in sbt-2 well, and 0.0259 in sbt-3 well. Dimensionless time and dimensionless wellbore storage were estimated by use of transmissivity, storativity, test time, and specification of test wells. And, dimensionless drawdown were selected by parameter ${\alpha}\;and\;{\beta}$ parameter from Cooper et al. (1967). Radius of influence were estimated by estimated dimensionless time, dimensionless wellbore storage, and dimensionless drawdown. The average radius of influnce for slug/bail tests were estimated to be 1.377 m in sbt-1 well, 1.253 m in sbt-2 well, and 1.558 m in sbt-3 well. Pore volume at groundwater level drawdown zone by dummy withdrawal for bail tests were estimated to be $145,636cm^3$ in sbt-1 well, $71,561cm^3$ in sbt-2 well, and $100,418cm^3$ in sbt-3 well. Pore volume excepted well volume at groundwater level drawdown zone by dummy withdrawal for bail tests were estimated to be $145,410cm^3$ in sbt-1 well, $71,353cm^3$ in sbt-2 well, and $100,192cm^3$ in sbt-3 well.

암반공압파쇄에 의한 지하수량 증대효과 분석

  • 김혜빈;부성안;이기철;김종태
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.47-50
    • /
    • 2003
  • We carried out rock pneumatic fracturing test which to increase groundwater yield by injection of highly pressured air in artificially under the surface every four borehole. The result of test performing shows that effect of increasing groundwater was not found in three testhole around igneous and metamorphic formation area, but we can realized that about 15 percent increased wateryield appeared in number P-5 test hole at sedimmentary rock formation.

  • PDF

Analysis of Pumping Test Data and The Prediction of Drawdown for Daejong-Chun Area (대종천유역 충적대수층의 수리성 분석 및 수위강하예측에 관한 연구)

  • Choi, Jae-Jin;Sung, Won-Mo;Hahn, Jeong-Sang
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.541-549
    • /
    • 1993
  • The main goal of this paper is to determine hydraulic properties and to predict drawdown for the efficient and stable development of groundwater in the Daejong-Chun area, North of Kyungsang-Do. Based on geological survey and analysis of well logging data conducted in 1991, it is found that the type of aquifer of this area is considered to be an anisotropic unconfined aquifer with saturated thickness of 19.8 m. In order to characterize this aquifer pumping test was conducted, and the resulting drawdown data were utilized for the analysis by applying both type curve matching technique and semi-log straight line method. As a result, the average specific yield of this aquifer is estimated as 32.3%, and the average ratio of $K_H$ to $K_V$ is only 2.7, which means that gravitational effect is not significant factor for this type of aquifer. For the validation of the estimated hydraulic properties, the analytical model which was developed with Newton-Raphson iteration procedure in this study, was employed to generate the drawdown. And, the resulting drawdown was compared against actual drawdown data and it shows the excellent matches. The actual drawdown data for 9 hours of pumping were used for history matching purposes and relatively satisfactory matches were achieved in this match. Then, the model was run by using the tuned parameters that are obtained during history matching stage, and the drawdown was predicted for the next 30 years of pumping with $3,000m^3/day$ of constant pumping rate. Its result indicates that the drawdown was stabilized as 1.41 m from 20 days with $3,000m^3/day$ of constant pumping rate, which is the required amount of water to be safely supplied to this area.

  • PDF

Parameter estimation for identification on cause of drawdown around underground LPG storage cavern (지하 LPG저장공동 주변의 지하수위 강하 원인규명을 위한 파라미터추정)

  • Han, Il-Yeong;Lee, Dae-Hyuck;Lee, Jung-Eun;Jung, Kwang-Pil
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.76-80
    • /
    • 1998
  • In order to identify the cause of ground water drawdown of a piezometer installed around the LPG storage cavern, parameter estimations were conducted by inverse and forward numerical models. An inverse model, SK-EST developed by SK Engineering & Construction Co., Ltd.(SKEC,1997) was performed to estimate the change of the hydraulic conductivity. It was verified by the commercial forward model, AQUA3D (VATNASKIL,1995). The simulation results showed that the hydraulic diffusivity of the rock mass between the piezometer and the cavern had been increased and the change rate of the hydraulic head had been abruptly increased in response to the change of the operation pressure. Finally the statistical analysis for observed data showed the increase of the change rate of the hydraulic head and thus proved the applicability of SK-EST.

  • PDF

Geochemical Characteristics of Groundwater during the Constant and Step-drawdown Pumping Tests at the River Bank Filtration Site (장기 및 단계 양수시험 시 강변여과 지하수의 수질변화 특성)

  • Kim, Gyoobum;Shin, Seonho;Kim, Byungwoo;Park, Joonhyung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.11-21
    • /
    • 2013
  • In-situ test to find the change of $Fe^{2+}$ and $Mn^{2+}$ concentrations and ion contents in groundwater was conducted during two pumping tests at the riverbank filtration site, where is the riverine area of the Nakdong River in Changnyeong-Gun. Groundwater was sampled at one pumping well and 10 monitoring wells during a 5 steps drawdown pumping test with the rates from $500m^3/day$ to $900m^3/day$ and a constant pumping test with $800m^3/day$. The change in ion concentration of groundwater was more remarkable during a step drawdown pumping test than a constant pumping test. Especially, the decrease in $Fe^{2+}$ and $Mn^{2+}$ concentrations was distinct in a step drawdown pumping test and it happens predominantly along the direction that the radius of pumping influence was small due to a good aquifer connectivity to a pumping position. The precipitation and the oxidation of iron and manganese were caused by an air inflow and a disturbance in groundwater flow due to an abrupt change in pumping rate. The pumping rate and spatial distribution of an aquifer around a pumping well need to be considered as an important factor for the development of in-situ iron and manganese treatment technology.

Relationship between Groundwater Level Changes and Aquifer Characteristics during Pumping at a Radial Collector Well (방사형 집수정 취수시 대수층 특성에 따른 지하수위의 변화)

  • Choi, Myoung-Rak;Lee, Ho-Jeong;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.279-288
    • /
    • 2019
  • The groundwater drawdown at each monitoring well near a radial collector well along Anseong Stream, Korea, was measured and compared with the calculated drawdown using the mirror well concept. The drawdown calculation is performed by treating the collector well as a large vertical well in a homogeneous isotropic aquifer. The measured drawdown at each monitoring well is slightly different from the calculated value due to anisotropy in the hydraulic conductivity and aquifer thickness. The difference between the measured and calculated values at Well OW-7 is large, reaching approximately 48 cm, because a horizontal well is not installed along this direction. Sensitivity analysis of the hydraulic conductivity and aquifer thickness indicates that the hydraulic conductivity is more sensitive to groundwater level changes. Groundwater level changes become a concern when a radial collector well with a large pumping rate capacity is installed, which highlights the need to thoroughly investigate the aquifer characteristics in the surrounding area.

Groundwater-surface water interaction of the upstream area of the dam composed of accumulated sediments and reservoir in the upstream area of Searsvill Dam (Searsville 댐 상류부를 대상으로 한 퇴적토와 저수지로 구성된 지하수 시스템의 지하수-지표수 상호작용)

  • Kim, Dongkyun
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.43-50
    • /
    • 2013
  • The groundwater-surface water interaction of Searsville Lake area, California, US was analyzed using 3-dimensional groundwater model. This study especially focuses on investigating the groundwater head drawdown near the lake when the abrupt decline of the lake water table occurs due to the implementation of the options to remove the accumulated sediments along the dam. The result of the investigation revealed that the groundwater head drawdown near the lake is not significant enough to adversely affect the wetland habitat of the area regardless of the hydrogeologic parameters of the aquifers. We expect this result provides useful information to the similar Korean case studies in which the surface water level abruptly changes due to the operation of the hydraulic gates of dams and wiers and the corresponding environmental impact should be considered.

Evaluation of Effects of Groundwater Pumping Near Stream Using Analytical Model (해석적 모형에 의한 하천변 지하수 양수 영향 분석)

  • Lee, Jeongwoo;Chung, Il-Moon;Kim, Nam Won;Lee, Min Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.617-625
    • /
    • 2016
  • The objective of this study was to evaluate the groundwater drawdown and streamflow depletion due to each groundwater pumping from 110 wells located near stream using the Hunt's analytical solution (1999). The calculated results revealed that the streamflow depletion rate divided by the pumping rate for each well location mostly exceeded about 80% of pumping rate on average for 5 years. The results also showed that the stream boundary condition has made the influence distance shorter and the drawdown distribution skewed except for the streambed hydraulic conductivity and the stream bed factor (SBF) lower than $1.0{\times}10^{-9}m/s$ and 1.0, respectively. It was found that the groundwater pumping has significant impacts on the stream depletion showing above 80 % of stream depletion rate when the streambed hydraulic conductivity is higher than $1.0{\times}10^{-7}m/s$ and the stream depletion factor(SDF) is lower than 100. However, for other conditions, the SDF is not sufficient to be used as a criterion for determining whether the pumping has great impacts on stream depletion or not. Furthermore, the variation of the streambed hydraulic conductance has little change in stream depletion rate for the condition that the stream width is greater than 400 m.