Browse > Article

The Pore Volume of Groundwater Level Drawdown Zone Through Slug/Bail Tests in Sand and Silt Soils  

Kim, Tae-Yeong (Department of Environmental Geosciences, Pukyong National University)
Kang, Dong-Hwan (Institute of Environmental Geosciences of Pukyong National University)
Chung, Sang-Yong (Department of Environmental Geosciences, Pukyong National University)
Yang, Sung-Il (Department of Environmental Geosciences, Pukyong National University)
Lee, Min-Hee (Department of Environmental Geosciences, Pukyong National University)
Publication Information
Journal of Soil and Groundwater Environment / v.12, no.4, 2007 , pp. 1-7 More about this Journal
Abstract
Slug/bail tests were conducted in sand layer (sbt-1 well), silty sand layer (sbt-2 well), and mixed sand and silty sand layer (sbt-3 well). Hydraulic conductivity and specific storage coefficient were estimated through slug/bail tests. Pore volumes of groundwater level drawdown zone for bail test were estimated by using hydraulic conductivity and specific storage coefficient. KGS model was most suitable interpretation method of slug/bail tests. Average hydraulic conductivity for slug/bail tests were estimated to be $6.65{\times}10^{-5}$ m/sec in sbt-1 well, $6.33{\times}10^{-6}$ m/sec in sbt-2 well, and $3.72{\times}10^{-5}$ m/sec in sbt-3 well. Average specific storage coefficient for slug/bail tests were estimated to be 0.0225 in sbt-1 well, 0.0177 in sbt-2 well, and 0.0259 in sbt-3 well. Dimensionless time and dimensionless wellbore storage were estimated by use of transmissivity, storativity, test time, and specification of test wells. And, dimensionless drawdown were selected by parameter ${\alpha}\;and\;{\beta}$ parameter from Cooper et al. (1967). Radius of influence were estimated by estimated dimensionless time, dimensionless wellbore storage, and dimensionless drawdown. The average radius of influnce for slug/bail tests were estimated to be 1.377 m in sbt-1 well, 1.253 m in sbt-2 well, and 1.558 m in sbt-3 well. Pore volume at groundwater level drawdown zone by dummy withdrawal for bail tests were estimated to be $145,636cm^3$ in sbt-1 well, $71,561cm^3$ in sbt-2 well, and $100,418cm^3$ in sbt-3 well. Pore volume excepted well volume at groundwater level drawdown zone by dummy withdrawal for bail tests were estimated to be $145,410cm^3$ in sbt-1 well, $71,353cm^3$ in sbt-2 well, and $100,192cm^3$ in sbt-3 well.
Keywords
Soils; Slug/bail test; Radius of influence; Groundwater level drawdown zone; Pore volume;
Citations & Related Records
연도 인용수 순위
  • Reference
1 한혜정, 최종근, 2000, 유한요소기법을 이용한 Slug시험 모델의 타당성 및 유용성 연구, 지하수환경, 7(2), 89-96
2 Bouwer, H. and Rice, R.C., 1976, A slug test method for determining hydraulic conductivity of unconfined aquifers with completely or partially penetrating wells, Water Resour. Res., 12(3), 423-428   DOI
3 부산철도차량관리단, 2005, 부산철도차량관리단 지하수오염확산 모니터링 보고서, p. 115
4 Rovey, C.W. and Cherkauer D.S., 1995, Scale dependency of hydraulic conductivity measurements, Ground Water, 33(5), 769-780   DOI   ScienceOn
5 이진용, 이강근, 정형재, 배광옥, 1999, 순간수위변화 및 양수시험을 통한 수리상수 산정의 문제점 분석, 지하수환경, 6(1), 14-22
6 Karasaki, K., Long, J.C.S., and Witherspoon, 1988, Analytical model of slug tests, Water Resour. Res., 24(1), 115-126   DOI
7 Cooper, H.H., Bredehoeft, J.D., and Papadopulos, I.S., 1967, Response of a finite-diameter well to an instantaneous charge of water, Water Resour. Res., 3(1), 263-269   DOI
8 함세영, 김문수, 성익환, 이병대, 김광성, 2001, 순간충격시험에 의한 화강암지역의 수리적 매개변수 산출, 지질공학, 11(1), 63-79
9 Barker, J.A. and Black, J.H., 1983, Slug tests in fissured aquifers, Water Resour. Res., 19(6), 1558-1564   DOI
10 Hyder Z., Butler Jr, J.J., McElwee, C.D., and Lui, W.Z., 1994, Slug tests in partially penetrating wells, Water Resour. Res., 30(11), 2945-2957   DOI   ScienceOn
11 Sageev, A., Slug test analysis, 1986, Water Resour. Res., 22(8), 1323-1333   DOI
12 Ferris, J.G., Knowles, D.B., Brown, R.H., and Stallman, R.W., 1962, Theory of aquifer tests. US Geology Survey. Water-Supply Paper 1536-E
13 Todd, D.K. and Mays, L.W., 2005, Groundwater Hydrology, Third edition, WILEY p. 353-255
14 Guyonnet, D., Mishra, S., and McCord, J., 1993, Evaluating the volume of porous medium investigated during slug tests, Ground Water, 31(4), 627-633   DOI   ScienceOn